619 research outputs found

    Design and analysis of a wire-driven flexible manipulator for bronchoscopic interventions

    Get PDF
    Bronchoscopic interventions are widely performed for the diagnosis and treatment of lung diseases. However, for most endobronchial devices, the lack of a bendable tip restricts their access ability to get into distal bronchi with complex bifurcations. This paper presents the design of a new wire-driven continuum manipulator to help guide these devices. The proposed manipulator is built by assembling miniaturized blocks that are featured with interlocking circular joints. It has the capability of maintaining its integrity when the lengths of actuation wires change due to the shaft flex. It allows the existence of a relatively large central cavity to pass through other instruments and enables two rotational degrees of freedom. All these features make it suitable for procedures where tubular anatomies are involved and the flexible shafts have to be considerably bent in usage, just like bronchoscopic interventions. A kinematic model is built to estimate the relationship between the translations of actuation wires and the manipulator tip position. A scale-up model is produced for evaluation experiments and the results validate the performance of the proposed mechanism

    Handheld Devices for Laparoscopic Surgery

    Get PDF
    Despite the well-known benefits of minimally invasive surgery (MIS) to the patients, this surgical technique implies some technical challenges for surgeons. These technical limitations are increased with the introduction of laparoendoscopic single-site (LESS) surgery. In order to overcome some of these technical difficulties, new handheld devices have been developed, providing improved functionalities along with precision-driven and articulating instrument tips. In this chapter, we will review the current status of handheld devices for laparoscopy and LESS surgery. Devices that provide additional and innovative functionalities in comparison with conventional surgical instruments will be considered. Results will be based on studies published in the scientific literature and our experience. These surgical devices will be organized into two main groups, mechanical devices and robotic-driven devices. In general, these instruments intend to simulate the dexterity of movements of a human wrist. Mechanical devices are cheaper and easier to develop, so most of the available handheld instruments fall into this category. The majority of the robotic-driven devices are needle holders with an articulating tip, controlled by an interface implemented on the instrument handle. In general, these handheld devices claim to offer an enhancement of dexterity, precision, and ergonomics

    Snake-Like Robots for Minimally Invasive, Single Port, and Intraluminal Surgeries

    Full text link
    The surgical paradigm of Minimally Invasive Surgery (MIS) has been a key driver to the adoption of robotic surgical assistance. Progress in the last three decades has led to a gradual transition from manual laparoscopic surgery with rigid instruments to robot-assisted surgery. In the last decade, the increasing demand for new surgical paradigms to enable access into the anatomy without skin incision (intraluminal surgery) or with a single skin incision (Single Port Access surgery - SPA) has led researchers to investigate snake-like flexible surgical devices. In this chapter, we first present an overview of the background, motivation, and taxonomy of MIS and its newer derivatives. Challenges of MIS and its newer derivatives (SPA and intraluminal surgery) are outlined along with the architectures of new snake-like robots meeting these challenges. We also examine the commercial and research surgical platforms developed over the years, to address the specific functional requirements and constraints imposed by operations in confined spaces. The chapter concludes with an evaluation of open problems in surgical robotics for intraluminal and SPA, and a look at future trends in surgical robot design that could potentially address these unmet needs.Comment: 41 pages, 18 figures. Preprint of article published in the Encyclopedia of Medical Robotics 2018, World Scientific Publishing Company www.worldscientific.com/doi/abs/10.1142/9789813232266_000

    Cable-driven parallel mechanisms for minimally invasive robotic surgery

    Get PDF
    Minimally invasive surgery (MIS) has revolutionised surgery by providing faster recovery times, less post-operative complications, improved cosmesis and reduced pain for the patient. Surgical robotics are used to further decrease the invasiveness of procedures, by using yet smaller and fewer incisions or using natural orifices as entry point. However, many robotic systems still suffer from technical challenges such as sufficient instrument dexterity and payloads, leading to limited adoption in clinical practice. Cable-driven parallel mechanisms (CDPMs) have unique properties, which can be used to overcome existing challenges in surgical robotics. These beneficial properties include high end-effector payloads, efficient force transmission and a large configurable instrument workspace. However, the use of CDPMs in MIS is largely unexplored. This research presents the first structured exploration of CDPMs for MIS and demonstrates the potential of this type of mechanism through the development of multiple prototypes: the ESD CYCLOPS, CDAQS, SIMPLE, neuroCYCLOPS and microCYCLOPS. One key challenge for MIS is the access method used to introduce CDPMs into the body. Three different access methods are presented by the prototypes. By focusing on the minimally invasive access method in which CDPMs are introduced into the body, the thesis provides a framework, which can be used by researchers, engineers and clinicians to identify future opportunities of CDPMs in MIS. Additionally, through user studies and pre-clinical studies, these prototypes demonstrate that this type of mechanism has several key advantages for surgical applications in which haptic feedback, safe automation or a high payload are required. These advantages, combined with the different access methods, demonstrate that CDPMs can have a key role in the advancement of MIS technology.Open Acces

    Three-Axis Fiber-Optic Body Force Sensor for Flexible Manipulators

    Get PDF
    This paper proposes a force/torque sensor structure that can be easily integrated with a flexible manipulator structure. The sensor’s ring-like structure with its hollow inner section provides ample space for auxiliary components, such as cables and tubes, to be passed through and, hence, is very suitable for integration with tendon-driven and fluid-actuated manipulators. The sensor structure can also accommodate the wiring for a distributed sensor system as well as for diagnostic instruments that may be incorporated in the manipulator. Employing a sensing approach based on optical fibers as done here allows for the creation of sensors that are free of electrical currents at the point of sensing and immune to magnetic fields. These sensors are inherently safe when used in the close vicinity of humans and their measuring performance is not impaired when they are operated in or nearby machines such as magnetic resonance imaging (MRI) scanners. This type of sensor concept is particularly suitable for inclusion in instruments and robotic tools for minimally invasive surgery (MIS). The paper summarizes the design, integration challenges and calibration of the proposed optical three-axis force sensor. The experimental results confirm the effectiveness of our optical sensing approach and show that after calibrating its stiffness matrix, force and momentum components can be determined accurately

    Three-Axis Fiber-Optic Body Force Sensor for Flexible Manipulators

    Get PDF
    This paper proposes a force/torque sensor structure that can be easily integrated into a flexible manipulator structure. The sensor's ring-like structure with its hollow inner section provides ample space for auxiliary components, such as cables and tubes, to be passed through and, hence, is very suitable for integration with tendon-driven and fluid-actuated manipulators. The sensor structure can also accommodate the wiring for a distributed sensor system as well as for diagnostic instruments that may be incorporated in the manipulator. Employing a sensing approach based on optical fibers as done here allows for the creation of sensors that are free of electrical currents at the point of sensing and immune to magnetic fields. These sensors are inherently safe when used in the close vicinity of humans and their measuring performance is not impaired when they are operated in or nearby machines, such as magnetic resonance imaging scanners. This type of sensor concept is particularly suitable for inclusion in instruments and robotic tools for minimally invasive surgery. This paper summarizes the design, integration challenges, and calibration of the proposed optical three-axis force sensor. The experimental results confirm the effectiveness of our optical sensing approach and show that after calibrating its stiffness matrix, force and momentum components can be determined accurately

    Rolling-joint design optimization for tendon driven snake-like surgical robots

    Get PDF
    The use of snake-like robots for surgery is a popular choice for intra-luminal procedures. In practice, the requirements for strength, flexibility and accuracy are difficult to be satisfied simultaneously. This paper presents a computational approach for optimizing the design of a snake-like robot using serial rolling-joints and tendons as the base architecture. The method optimizes the design in terms of joint angle range and tendon placement to prevent the tendons and joints from colliding during bending motion. The resulting optimized joints were manufactured using 3D printing. The robot was characterized in terms of workspace, dexterity, precision and manipulation forces. The results show a repeatability as low as 0.9mm and manipulation forces of up to 5.6N

    From passive tool holders to microsurgeons: safer, smaller, smarter surgical robots

    No full text
    • …
    corecore