32 research outputs found

    Analysis of Ultra Wide Band (UWB) Technology for an Indoor Geolocation and Physiological Monitoring System

    Get PDF
    The goal of this research is to analyze the utility of UWB for indoor geolocation and to evaluate a prototype system, which will send information detailing a person’s position and physiological status to a command center. In a real world environment, geolocation and physiological status information needs to be sent to a command and control center that may be located several miles away from the operational environment. This research analyzes and characterizes the UWB signal in the various operational environments associated with indoor geolocation. Additionally, typical usage scenarios for the interaction between UWB and other devices are also tested and evaluated

    Ultra-Wideband Transceiver Design And Optimization

    Get PDF
    University of Minnesota Ph.D. dissertation. July 2015. Major: Electrical Engineering. Advisor: Ramesh Harjani. 1 computer file (PDF); xiii, 128 pages.The technology landscape has quickly changed over the last few years. Developments in personal area networks, IC technology, DSP processing and bio-medical devices have enabled the integration of short range communication into low cost personal health care solutions. Newer technologies and solutions are being developed to cater to the personal operating space(POS) and body area networks(BAN). Health care is driving towards using multiple sensor and therapeutic nodes inside the POS. Technology has enabled remote patient care where the patient has low cost on-body wearables that allow the patient/physician to access vital signs without the patient physically visiting the clinic. Big semiconductor giants want to move into the wearable health monitor space. Along with the developments in fitness based health wearables, there has been a lot of interest towards developing BAN devices catering to the 'mission-critical' wearables and implants. Hearing aids, EKG monitors, neurostimulators are some examples. This work explores the use of the 802.15 ulta wideband (UWB) standard for designing a radio to operate in the a wireless sensor network in the BAN. The specific application targeted is a hearing aid. However, the design in this work is capable of working in a low power low range application with the ability to have multiple data rates ranging from a few kHz to 10's of MHz. The first radio designed by Marconi using spark-gap transmitters was an impulse radio (IR). The IR UWB technology boasts of low power, low cost, high data rates, multiple channels, simultaneous networking, the ability to carry information through obstacles that more limited bandwidths cannot, and also potentially lower complexity hardware design. The inherent timing accuracy associated with the technology gives UWB transmissions immunity to multipath fading and are hence make them more suitable for a cluttered indoor environment. The key difference with the traditional narrowband transceiver is that instead of using continuous wave (CW) transmission, impulses in time are used. The timing accuracy associated with these impulses require synchronization in time, rather than synchronization in frequency for carrier-based CW systems. A complete fully integrated system is presented in thesis. This work presents a low-power noncoherent IR UWB transceiver operating at 5GHz in 0.13um CMOS. A fully-digital transmitter generates a shaped output pulse of 1GHz 3-dB bandwidth. DLLs provide a PVT-tolerant time-step resolution of 1ns over the entire symbol period and regulate the pulse generator center frequency. The transmitter outputs -31dBm (0.88pJ/pulse at 1Mpulse/s) with a dynamic (energy) efficiency of 16pJ/pulse. The transmit out pulse is FCC part 15 compliant over process voltage and temperature (PVT) variations. The transmitter is semi-compliant with IEEE 802.15.6 and IEEE 802.15.4 standards and will become completely compliant with minor modifications. The receiver presented in this work is a non-coherent energy detect IR UWB receiver. The receiver has an on-chip transformer preceding the LNA, which is followed by a super-regenerative amplifier (SRA), envelope detector, sample-and-holds, and a bank of comparators. The design is SRA based energy-detection receiver. Measured results show a receiver efficiency of 0.32nJ/bit at 20.8Mb/s and operation with inputs as low as -70dBm. The SRA based energy-detection receiver utilizes early/late detection for a two-step baseband synchronization algorithm. An integrated solution to the issue of synchronization is also proposed. The system proposed is capable of synchronization and tracking control. The system in this work utilizes early/late detection for a two-step baseband synchronization algorithm. The algorithm is implemented in Matlab and the time to synchronization is observed to be between 250us to a few couple of ms. Measurements have also been made using the receiver and manually implementing the algorithm. This work addresses all aspects time synchronization in an IR transceiver. The initial mismatch is addressed by two methods. Beyond the initial synchronization, the system presented in this system is also capable of tracking. This would mean that once the transceiver has been synchronized, the timing generation would continue to track the phase and the frequency changes depending upon crystal drift over time or movement between the receiver and the transmitter. A test was also performed on the complete transceiver system with two radios talking to each other over a highly attenuated wired channel

    LOW-POWER IMPULSE-RADIO ULTRA-WIDEBAND TECHNIQUES FOR BIOMEDICAL APPLICATIONS.

    Get PDF
    Ph.DDOCTOR OF PHILOSOPH

    A dual-mode Ultra-Wideband wireless platform for remote patient monitoring systems

    Get PDF
    The combination of two factors demands the need to find a solution that guarantees the well-being of the people suffering from chronic diseases. On the one hand, the increase of the life expectancy leads to an older world's population. On the other hand, the aged are more likely to suffer from chronic diseases and/or injuries. This thesis deals with the design of an Ultra-Wideband-based node of a Remote Patient Monitoring (RPM) network. This node must be able to measure, collect and transmit some medical parameters of a patient. Existing RPM networks use two different hardware platforms: one for measuring and another one for transmitting. This leads to high cost and high power consumption. Since a RPM network is typically composed by hundreds or thousands of nodes, a new platform with lower cost and power consumption is vital to make such a system work. This thesis explores the viability to achieve the dual-mode operation: Radar Mode (RM) to obtain a certain parameter and Data Transmission Mode (DTM) to send it to another node. A platform using Impulse-Radio Ultra-Wideband (IR-UWB) has been proposed to accomplish this goal. The simulations done verified its feasibility. Moreover, the physical experiments carried out validated the transmitter. Nevertheless, due to time and hardware limitations, the receiver has not been experimentally validated yet

    Digital ADCs and ultra-wideband RF circuits for energy constrained wireless applications by Denis Clarke Daly.

    Get PDF
    Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2009.Cataloged from PDF version of thesis.Includes bibliographical references (p. 173-183).Ongoing advances in semiconductor technology have enabled a multitude of portable, low power devices like cellular phones and wireless sensors. Most recently, as transistor device geometries reach the nanometer scale, transistor characteristics have changed so dramatically that many traditional circuits and architectures are no longer optimal and/or feasible. As a solution, much research has focused on developing 'highly digital' circuits and architectures that are tolerant of the increased leakage, variation and degraded voltage headrooms associated with advanced CMOS processes. This thesis presents several highly digital, mixed-signal circuits and architectures designed for energy constrained wireless applications. First, as a case study, a highly digital, voltage scalable flash ADC is presented. The flash ADC, implemented in 0.18 [mu]m CMOS, leverages redundancy and calibration to achieve robust operation at supply voltages from 0.2 V to 0.9 V. Next, the thesis expands in scope to describe a pulsed, noncoherent ultra-wideband transceiver chipset, implemented in 90 nm CMOS and operating in the 3-to-5 GHz band. The all-digital transmitter employs capacitive combining and pulse shaping in the power amplifier to meet the FCC spectral mask without any off-chip filters. The noncoherent receiver system-on-chip achieves both energy efficiency and high performance by employing simple amplifier and ADC structures combined with extensive digital calibration. Finally, the transceiver chipset is integrated in a complete system for wireless insect flight control.(cont.) Through the use of a flexible PCB and 3D die stacking, the total weight of the electronics is kept to 1 g, within the carrying capacity of an adult Manduca sexta moth. Preliminary wireless flight control of a moth in a wind tunnel is demonstrated.Ph.D
    corecore