5,156 research outputs found

    A 0.1–5.0 GHz flexible SDR receiver with digitally assisted calibration in 65 nm CMOS

    Get PDF
    © 2017 Elsevier Ltd. All rights reserved.A 0.1–5.0 GHz flexible software-defined radio (SDR) receiver with digitally assisted calibration is presented, employing a zero-IF/low-IF reconfigurable architecture for both wideband and narrowband applications. The receiver composes of a main-path based on a current-mode mixer for low noise, a high linearity sub-path based on a voltage-mode passive mixer for out-of-band rejection, and a harmonic rejection (HR) path with vector gain calibration. A dual feedback LNA with “8” shape nested inductor structure, a cascode inverter-based TCA with miller feedback compensation, and a class-AB full differential Op-Amp with Miller feed-forward compensation and QFG technique are proposed. Digitally assisted calibration methods for HR, IIP2 and image rejection (IR) are presented to maintain high performance over PVT variations. The presented receiver is implemented in 65 nm CMOS with 5.4 mm2 core area, consuming 9.6–47.4 mA current under 1.2 V supply. The receiver main path is measured with +5 dB m/+5dBm IB-IIP3/OB-IIP3 and +61dBm IIP2. The sub-path achieves +10 dB m/+18dBm IB-IIP3/OB-IIP3 and +62dBm IIP2, as well as 10 dB RF filtering rejection at 10 MHz offset. The HR-path reaches +13 dB m/+14dBm IB-IIP3/OB-IIP3 and 62/66 dB 3rd/5th-order harmonic rejection with 30–40 dB improvement by the calibration. The measured sensitivity satisfies the requirements of DVB-H, LTE, 802.11 g, and ZigBee.Peer reviewedFinal Accepted Versio

    A Low-Power Passive UHF Tag With High-Precision Temperature Sensor for Human Body Application

    Get PDF
    Radio frequency identification (RFID) tags are widely used in various electronic devices due to their low cost, simple structure, and convenient data reading. This topic aims to study the key technologies of ultra-high frequency (UHF) RFID tags and high-precision temperature sensors, and how to reduce the power consumption of the temperature sensor and the overall circuits while maintaining minimal loss of performance. Combined with the biomedicine, an innovative high-precision human UHF RFID chip for body temperature monitoring is designed. In this study, a ring oscillator whose output frequency is linearly related to temperature is designed and proposed as a temperature-sensing circuit by innovatively combining auxiliary calibration technology. Then, a binary counter is used to count the pulses, and the temperature is ultimately calculated. This topic designed a relaxation oscillator independent of voltage and current. The various types of resistors were used to offset the temperature deviation. A current mirror array calibration circuit is used to calibrate the process corner deviation of the clock circuit with a self-calibration algorithm. This study mainly contributes to reducing power consumption and improving accuracy. The total power consumption of the RF/analog front-end and temperature sensor is 7.65”W. The measurement error of the temperature sensor in the range of 0 to 60◩C is less than ±0.1%, and the accuracy of the output frequency of the clock circuit is ±2.5%

    Fault-tolerant design of RF front-end circuits

    Get PDF
    The continuing trends of scaling in the CMOS industry have, inevitably, been accompanied by an ever-increasing array of process faults and fabrication complexities. The relentless march towards miniaturization and massive integration, in addition to increasing operating frequencies has resulted in increasing concerns about the reliability of integrated RF front-ends. Coupled with rising cost per chip, the fault-tolerant paradigm has become pertinent in the RFIC domain. Two main reasons have contributed to the fact that fault-tolerant solutions for circuits that operate in the GHz domain have not been realized so far. First, GHz signals are extremely sensitive to higher-order effects such as stray pick-ups, interference, package & on-chip parasitics, etc. Secondly, the use of passives, especially inductors, in the feedback path poses huge area overheads, in addition to a slew of instability problems due to wide variations and soft faults. Hence traditional fault-tolerance methods used in digital and low frequency analog circuits cannot be applied in the RF domain. This work presents a unique methodology to achieve fault-tolerance in RF circuits through dynamic sensing and on-chip self-correction, along with the development of robust algorithms. This technique is minimally intrusive and is transparent during \u27normal\u27 use of the circuit. It is characterized by low area and power overheads, does not need any off-chip computing or DSP cores, and is characterized by self-correction times in the range of a few hundreds of microseconds. It compares very well with existing commercial RF test solutions that use DSP cores and require hundreds of milliseconds. The methodology is demonstrated on a LNA, since it is critical for the performance of the entire front-end. It is validated with simulation and fabrication results of the system designed in IBM 0.25 ”m CMOS 6RF process

    Digitally-Assisted RF IC Design Techniques for Reliable Performance

    Get PDF
    Semiconductor industries have competitively scaled down CMOS devices to attain benefits of low cost, high performance, and high integration density in digital integrated circuits. On the other hand, deep scaled technologies inextricably accompany a large process variation, supply voltage scaling, and reduction in breakdown voltages of transistors. When it comes to RF/analog IC design, CMOS scaling adversely affects its reliability due to large performance variation and limited linearity. For addressing the issues related to variations and linearity, this research proposes the following digitally-assisted RF circuit design techniques: self-calibration system for RF phase shifters and wide dynamic range LNAs. Due to PVT variations in scaled technologies, RF phase shifter design becomes more challenging with device scaling. In the proposed self-calibration topology, we devised a novel phase sensing method and a pulsewidth-to-digital converter. The feedback controller is also designed in digital domain, which is robust to PVT variations. These unique techniques enable a sensing/control loop tolerant to PVT variations. The self-calibration loop was applied to a 7 to 13GHz phase shifter. With the calibration, the estimated phase error is less than 2 degrees. To overcome the linearity issue in scaled technologies, a digitally-controlled dual-mode LNA design is presented. A narrowband (5.1GHz) and a wideband (0.8 to 6GHz) LNA can be toggled between high-gain and high-linearity modes by digital control bits according to the input signal power. A compact design, which provides negligible performance degradation by additional circuitry, is achieved by sharing most of the components between the two operation modes. The narrowband and the wideband LNA achieves an input-referred P1dB of -1.8dBm and +4.2dBm, respectively

    Integrated Circuits for Medical Ultrasound Applications: Imaging and Beyond

    Get PDF
    Medical ultrasound has become a crucial part of modern society and continues to play a vital role in the diagnosis and treatment of illnesses. Over the past decades, the develop- ment of medical ultrasound has seen extraordinary progress as a result of the tremendous research advances in microelectronics, transducer technology and signal processing algorithms. How- ever, medical ultrasound still faces many challenges including power-efficient driving of transducers, low-noise recording of ultrasound echoes, effective beamforming in a non-linear, high- attenuation medium (human tissues) and reduced overall form factor. This paper provides a comprehensive review of the design of integrated circuits for medical ultrasound applications. The most important and ubiquitous modules in a medical ultrasound system are addressed, i) transducer driving circuit, ii) low- noise amplifier, iii) beamforming circuit and iv) analog-digital converter. Within each ultrasound module, some representative research highlights are described followed by a comparison of the state-of-the-art. This paper concludes with a discussion and recommendations for future research directions

    A SIX-PORT MEASUREMENT DEVICE FOR HIGH POWER MICROWAVE VECTOR NETWORK ANALYSIS

    Get PDF
    The changes experienced in technology due to the third industrial revolution have over the years contributed immensely to the development of efficient devices and systems. As a result, solutions have been provided to challenges encountered in the heating industry. However, higher efficiency and better performance has undoubtedly been highly sort after. This paper presents the complete industrial development of a new system of a microwave device for use in S-band networks (2.45 GHz ISM band in this application): a vector network analyzer (VNA). The VNA, which is designed based on the six-port measurement principle, provides accurate measurements of both magnitude and phase of the load reflection coefficient. The device is designed to have high power handling capabilities and works under the full operating conditions of high-power microwave generators. Initial measurements show that the device perform stable and can perform temperature-independent measurements over protracted periods. The system is suited for on-line monitoring and control of network parameters in industrial waveguide applications.

    Biotelemetry of the triaxial ballistocardiogram and electrocardiogram in a weightless environment

    Get PDF
    Biotelemetry of triaxial ballistocardiogram and electrocardiogram in weightless environmen
    • 

    corecore