43,514 research outputs found
Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery
One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-opera- tive morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilites by observ- ing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted in- struments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This paper reviews the state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery and discusses the technical challenges and future perspectives towards clinical translation. With the recent paradigm shift of surgical practice towards MIS and new developments in 3D opti- cal imaging, this is a timely discussion about technologies that could facilitate complex CAS procedures in dynamic and deformable anatomical regions
Motion compensated micro-CT reconstruction for in-situ analysis of dynamic processes
This work presents a framework to exploit the synergy between Digital Volume Correlation ( DVC) and iterative CT reconstruction to enhance the quality of high-resolution dynamic X-ray CT (4D-mu CT) and obtain quantitative results from the acquired dataset in the form of 3D strain maps which can be directly correlated to the material properties. Furthermore, we show that the developed framework is capable of strongly reducing motion artifacts even in a dataset containing a single 360 degrees rotation
PVR: Patch-to-Volume Reconstruction for Large Area Motion Correction of Fetal MRI
In this paper we present a novel method for the correction of motion
artifacts that are present in fetal Magnetic Resonance Imaging (MRI) scans of
the whole uterus. Contrary to current slice-to-volume registration (SVR)
methods, requiring an inflexible anatomical enclosure of a single investigated
organ, the proposed patch-to-volume reconstruction (PVR) approach is able to
reconstruct a large field of view of non-rigidly deforming structures. It
relaxes rigid motion assumptions by introducing a specific amount of redundant
information that is exploited with parallelized patch-wise optimization,
super-resolution, and automatic outlier rejection. We further describe and
provide an efficient parallel implementation of PVR allowing its execution
within reasonable time on commercially available graphics processing units
(GPU), enabling its use in the clinical practice. We evaluate PVR's
computational overhead compared to standard methods and observe improved
reconstruction accuracy in presence of affine motion artifacts of approximately
30% compared to conventional SVR in synthetic experiments. Furthermore, we have
evaluated our method qualitatively and quantitatively on real fetal MRI data
subject to maternal breathing and sudden fetal movements. We evaluate
peak-signal-to-noise ratio (PSNR), structural similarity index (SSIM), and
cross correlation (CC) with respect to the originally acquired data and provide
a method for visual inspection of reconstruction uncertainty. With these
experiments we demonstrate successful application of PVR motion compensation to
the whole uterus, the human fetus, and the human placenta.Comment: 10 pages, 13 figures, submitted to IEEE Transactions on Medical
Imaging. v2: wadded funders acknowledgements to preprin
Recent trends, technical concepts and components of computer-assisted orthopedic surgery systems: A comprehensive review
Computer-assisted orthopedic surgery (CAOS) systems have become one of the most important and challenging types of system in clinical orthopedics, as they enable precise treatment of musculoskeletal diseases, employing modern clinical navigation systems and surgical tools. This paper brings a comprehensive review of recent trends and possibilities of CAOS systems. There are three types of the surgical planning systems, including: systems based on the volumetric images (computer tomography (CT), magnetic resonance imaging (MRI) or ultrasound images), further systems utilize either 2D or 3D fluoroscopic images, and the last one utilizes the kinetic information about the joints and morphological information about the target bones. This complex review is focused on three fundamental aspects of CAOS systems: their essential components, types of CAOS systems, and mechanical tools used in CAOS systems. In this review, we also outline the possibilities for using ultrasound computer-assisted orthopedic surgery (UCAOS) systems as an alternative to conventionally used CAOS systems.Web of Science1923art. no. 519
The INCF Digital Atlasing Program: Report on Digital Atlasing Standards in the Rodent Brain
The goal of the INCF Digital Atlasing Program is to provide the vision and direction necessary to make the rapidly growing collection of multidimensional data of the rodent brain (images, gene expression, etc.) widely accessible and usable to the international research community. This Digital Brain Atlasing Standards Task Force was formed in May 2008 to investigate the state of rodent brain digital atlasing, and formulate standards, guidelines, and policy recommendations.

Our first objective has been the preparation of a detailed document that includes the vision and specific description of an infrastructure, systems and methods capable of serving the scientific goals of the community, as well as practical issues for achieving
the goals. This report builds on the 1st INCF Workshop on Mouse and Rat Brain Digital Atlasing Systems (Boline et al., 2007, _Nature Preceedings_, doi:10.1038/npre.2007.1046.1) and includes a more detailed analysis of both the current state and desired state of digital atlasing along with specific recommendations for achieving these goals
- …