45,776 research outputs found
Recommended from our members
Expanding the use of real-time electromagnetic tracking in radiation oncology.
In the past 10 years, techniques to improve radiotherapy delivery, such as intensity-modulated radiation therapy (IMRT), image-guided radiation therapy (IGRT) for both inter- and intrafraction tumor localization, and hypofractionated delivery techniques such as stereotactic body radiation therapy (SBRT), have evolved tremendously. This review article focuses on only one part of that evolution, electromagnetic tracking in radiation therapy. Electromagnetic tracking is still a growing technology in radiation oncology and, as such, the clinical applications are limited, the expense is high, and the reimbursement is insufficient to cover these costs. At the same time, current experience with electromagnetic tracking applied to various clinical tumor sites indicates that the potential benefits of electromagnetic tracking could be significant for patients receiving radiation therapy. Daily use of these tracking systems is minimally invasive and delivers no additional ionizing radiation to the patient, and these systems can provide explicit tumor motion data. Although there are a number of technical and fiscal issues that need to be addressed, electromagnetic tracking systems are expected to play a continued role in improving the precision of radiation delivery
Serious interface design for dental health: Wiimote-based tangible interaction for school children
This paper describes a camera-based approach towards creating a tangible interface for serious games. We introduce our game for dental health targeted at school children which implements the Nintendo WiiMote as infrared camera. Paired with a gesture-recognition system, this combination allows us to apply real-world items as input devices. Thereby, the game tries to address different aspects of dental hygiene along with the improvement of children's motor skills. In our focus group test, we found that tangible interfaces offer great potential for educational purposes and can be used to engage kids in a playful learning process by addressing their childlike curiosity and fostering implicit learning
Evaluation of optimisation techniques for multiscopic rendering
A thesis submitted to the University of Bedfordshire in fulfilment of the requirements for the degree of Master of Science by ResearchThis project evaluates different performance optimisation techniques applied to stereoscopic and multiscopic rendering for interactive applications. The artefact
features a robust plug-in package for the Unity game engine. The thesis provides background information for the performance optimisations, outlines all the findings, evaluates the optimisations and provides suggestions for future work.
Scrum development methodology is used to develop the artefact and quantitative research methodology is used to evaluate the findings by measuring performance.
This project concludes that the use of each performance optimisation has specific use case scenarios in which performance benefits. Foveated rendering provides
greatest performance increase for both stereoscopic and multiscopic rendering but is also more computationally intensive as it requires an eye tracking solution.
Dynamic resolution is very beneficial when overall frame rate smoothness is needed and frame drops are present. Depth optimisation is beneficial for vast open environments but can lead to decreased performance if used inappropriately
Augmented Reality-based Feedback for Technician-in-the-loop C-arm Repositioning
Interventional C-arm imaging is crucial to percutaneous orthopedic procedures
as it enables the surgeon to monitor the progress of surgery on the anatomy
level. Minimally invasive interventions require repeated acquisition of X-ray
images from different anatomical views to verify tool placement. Achieving and
reproducing these views often comes at the cost of increased surgical time and
radiation dose to both patient and staff. This work proposes a marker-free
"technician-in-the-loop" Augmented Reality (AR) solution for C-arm
repositioning. The X-ray technician operating the C-arm interventionally is
equipped with a head-mounted display capable of recording desired C-arm poses
in 3D via an integrated infrared sensor. For C-arm repositioning to a
particular target view, the recorded C-arm pose is restored as a virtual object
and visualized in an AR environment, serving as a perceptual reference for the
technician. We conduct experiments in a setting simulating orthopedic trauma
surgery. Our proof-of-principle findings indicate that the proposed system can
decrease the 2.76 X-ray images required per desired view down to zero,
suggesting substantial reductions of radiation dose during C-arm repositioning.
The proposed AR solution is a first step towards facilitating communication
between the surgeon and the surgical staff, improving the quality of surgical
image acquisition, and enabling context-aware guidance for surgery rooms of the
future. The concept of technician-in-the-loop design will become relevant to
various interventions considering the expected advancements of sensing and
wearable computing in the near future
A passive infrared ice detection technique for helicopter applications
A technique has been developed, and successfully tested, to detect icing remotely on helicopter rotor blades. Using passive infrared (IR) thermometry it is possible to detect the warming caused by latent heat released as supercooled water freezes. During icing, the ice accretion region on the leading edge of the blade is found to be warmer than the uniced trailing edge resulting in a chordwise temperature profile characteristic of icing. Preliminary tests, using an IR Thermal video system, were conducted on a static model in the NASA Icing Research Tunnel (IRT) for a variety of wet (glaze) and dry (rime) ice conditions. A prototype detector system was built consisting of a single point IR pyrometer, and experiments were run on a small scale rotor model. Using this prototype detector, the characteristic chordwise temperature profiles were again observed for a range of icing conditions. Several signal processing methods were investigated, to allow automatic recognition of the icing signature. Additionally, several implementation issues were considered. Based on both the static and subscale rotor tests, where ice was successfully detected, the passive IR technique appears to be promising for rotor ice detection
- …