4,942 research outputs found

    Algebraic and analytic reconstruction methods for dynamic tomography.

    No full text
    In this work, we discuss algebraic and analytic approaches for dynamic tomography. We present a framework of dynamic tomography for both algebraic and analytic approaches. We finally present numerical experiments

    Free Software for PET Imaging

    Get PDF

    Topics in image reconstruction for high resolution positron emission tomography

    Get PDF
    Les problèmes mal posés représentent un sujet d'intérêt interdisciplinaire qui surgires dans la télédétection et des applications d'imagerie. Cependant, il subsiste des questions cruciales pour l'application réussie de la théorie à une modalité d'imagerie. La tomographie d'émission par positron (TEP) est une technique d'imagerie non-invasive qui permet d'évaluer des processus biochimiques se déroulant à l'intérieur d'organismes in vivo. La TEP est un outil avantageux pour la recherche sur la physiologie normale chez l'humain ou l'animal, pour le diagnostic et le suivi thérapeutique du cancer, et l'étude des pathologies dans le coeur et dans le cerveau. La TEP partage plusieurs similarités avec d'autres modalités d'imagerie tomographiques, mais pour exploiter pleinement sa capacité à extraire le maximum d'information à partir des projections, la TEP doit utiliser des algorithmes de reconstruction d'images à la fois sophistiquée et pratiques. Plusieurs aspects de la reconstruction d'images TEP ont été explorés dans le présent travail. Les contributions suivantes sont d'objet de ce travail: Un modèle viable de la matrice de transition du système a été élaboré, utilisant la fonction de réponse analytique des détecteurs basée sur l'atténuation linéaire des rayons y dans un banc de détecteur. Nous avons aussi démontré que l'utilisation d'un modèle simplifié pour le calcul de la matrice du système conduit à des artefacts dans l'image. (IEEE Trans. Nucl. Sei., 2000) );> La modélisation analytique de la dépendance décrite à l'égard de la statistique des images a simplifié l'utilisation de la règle d'arrêt par contre-vérification (CV) et a permis d'accélérer la reconstruction statistique itérative. Cette règle peut être utilisée au lieu du procédé CV original pour des projections aux taux de comptage élevés, lorsque la règle CV produit des images raisonnablement précises. (IEEE Trans. Nucl. Sei., 2001) Nous avons proposé une méthodologie de régularisation utilisant la décomposition en valeur propre (DVP) de la matrice du système basée sur l'analyse de la résolution spatiale. L'analyse des caractéristiques du spectre de valeurs propres nous a permis d'identifier la relation qui existe entre le niveau optimal de troncation du spectre pour la reconstruction DVP et la résolution optimale dans l'image reconstruite. (IEEE Trans. Nucl. Sei., 2001) Nous avons proposé une nouvelle technique linéaire de reconstruction d'image événement-par-événement basée sur la matrice pseudo-inverse régularisée du système. L'algorithme représente une façon rapide de mettre à jour une image, potentiellement en temps réel, et permet, en principe, la visualisation instantanée de distribution de la radioactivité durant l'acquisition des données tomographiques. L'image ainsi calculée est la solution minimisant les moindres carrés du problème inverse régularisé.Abstract: Ill-posed problems are a topic of an interdisciplinary interest arising in remote sensing and non-invasive imaging. However, there are issues crucial for successful application of the theory to a given imaging modality. Positron emission tomography (PET) is a non-invasive imaging technique that allows assessing biochemical processes taking place in an organism in vivo. PET is a valuable tool in investigation of normal human or animal physiology, diagnosing and staging cancer, heart and brain disorders. PET is similar to other tomographie imaging techniques in many ways, but to reach its full potential and to extract maximum information from projection data, PET has to use accurate, yet practical, image reconstruction algorithms. Several topics related to PET image reconstruction have been explored in the present dissertation. The following contributions have been made: (1) A system matrix model has been developed using an analytic detector response function based on linear attenuation of [gamma]-rays in a detector array. It has been demonstrated that the use of an oversimplified system model for the computation of a system matrix results in image artefacts. (IEEE Trans. Nucl. Sci., 2000); (2) The dependence on total counts modelled analytically was used to simplify utilisation of the cross-validation (CV) stopping rule and accelerate statistical iterative reconstruction. It can be utilised instead of the original CV procedure for high-count projection data, when the CV yields reasonably accurate images. (IEEE Trans. Nucl. Sci., 2001); (3) A regularisation methodology employing singular value decomposition (SVD) of the system matrix was proposed based on the spatial resolution analysis. A characteristic property of the singular value spectrum shape was found that revealed a relationship between the optimal truncation level to be used with the truncated SVD reconstruction and the optimal reconstructed image resolution. (IEEE Trans. Nucl. Sci., 2001); (4) A novel event-by-event linear image reconstruction technique based on a regularised pseudo-inverse of the system matrix was proposed. The algorithm provides a fast way to update an image potentially in real time and allows, in principle, for the instant visualisation of the radioactivity distribution while the object is still being scanned. The computed image estimate is the minimum-norm least-squares solution of the regularised inverse problem

    Mathematics and Algorithms in Tomography

    Get PDF
    This was the ninth Oberwolfach conference on the mathematics of tomography. Modalities represented at the workshop included X-ray tomography, radar, seismic imaging, ultrasound, electron microscopy, impedance imaging, photoacoustic tomography, elastography, emission tomography, X-ray CT, and vector tomography along with a wide range of mathematical analysis

    Smoothing dynamic positron emission tomography time courses using functional principal components

    Get PDF
    A functional smoothing approach to the analysis of PET time course data is presented. By borrowing information across space and accounting for this pooling through the use of a nonparametric covariate adjustment, it is possible to smooth the PET time course data thus reducing the noise. A new model for functional data analysis, the Multiplicative Nonparametric Random Effects Model, is introduced to more accurately account for the variation in the data. A locally adaptive bandwidth choice helps to determine the correct amount of smoothing at each time point. This preprocessing step to smooth the data then allows Subsequent analysis by methods Such as Spectral Analysis to be substantially improved in terms of their mean squared error

    Sensitivity correction of images obtained with the prototype Clear-PEM in pre-clinical environment

    Get PDF
    Dissertation presented at Faculdade de Ciências e Tecnologia Universidade Nova de Lisboa to obtain a Master Degree in Biomedical EngineeringNuclear medicine has, when compared to anatomical imaging techniques, the great advantage of identifying the metabolic activity of the cells, hence becoming a great option for tumour identification. A new technology in this area is Positron Emission Mammography (PEM) that follows the same physical basics of Positron Emission Tomography (PET). The Clear-PEM project, a Portuguese research project, uses this technology and, in alternative to the whole-body exam, only the breast is examined, using two detector plates that rotate around the breast to detect radiation. The prototype has the ability to perform a complementary exam of the axillary region. This scanner is designed to detect small lesions or tumours in early stages, with high resolution and high sensitivity. After the acquisition, the data undergoes a process of reconstruction and corrections. It is our job to study which parameters should be adjusted in order to get the best contrast between lesions and the breast background, as well as meeting the high resolution standards we set to achieve. This work consisted in the correction of some characteristics that might influence image quality. The first correction made was the elimination of the presence of the gaps between the detector crystals’ effects, resulting in the enhancement of the image Signal-to-Noise Ratio (SNR). By varying the energy window of the image acquisitions, it was possible to minimize the effect of scattered photons, and varying the timing window minimized the effect of random coincidences
    • …