3,175 research outputs found

    A Priority-based Fair Queuing (PFQ) Model for Wireless Healthcare System

    Get PDF
    Healthcare is a very active research area, primarily due to the increase in the elderly population that leads to increasing number of emergency situations that require urgent actions. In recent years some of wireless networked medical devices were equipped with different sensors to measure and report on vital signs of patient remotely. The most important sensors are Heart Beat Rate (ECG), Pressure and Glucose sensors. However, the strict requirements and real-time nature of medical applications dictate the extreme importance and need for appropriate Quality of Service (QoS), fast and accurate delivery of a patient’s measurements in reliable e-Health ecosystem. As the elderly age and older adult population is increasing (65 years and above) due to the advancement in medicine and medical care in the last two decades; high QoS and reliable e-health ecosystem has become a major challenge in Healthcare especially for patients who require continuous monitoring and attention. Nevertheless, predictions have indicated that elderly population will be approximately 2 billion in developing countries by 2050 where availability of medical staff shall be unable to cope with this growth and emergency cases that need immediate intervention. On the other side, limitations in communication networks capacity, congestions and the humongous increase of devices, applications and IOT using the available communication networks add extra layer of challenges on E-health ecosystem such as time constraints, quality of measurements and signals reaching healthcare centres. Hence this research has tackled the delay and jitter parameters in E-health M2M wireless communication and succeeded in reducing them in comparison to current available models. The novelty of this research has succeeded in developing a new Priority Queuing model ‘’Priority Based-Fair Queuing’’ (PFQ) where a new priority level and concept of ‘’Patient’s Health Record’’ (PHR) has been developed and integrated with the Priority Parameters (PP) values of each sensor to add a second level of priority. The results and data analysis performed on the PFQ model under different scenarios simulating real M2M E-health environment have revealed that the PFQ has outperformed the results obtained from simulating the widely used current models such as First in First Out (FIFO) and Weight Fair Queuing (WFQ). PFQ model has improved transmission of ECG sensor data by decreasing delay and jitter in emergency cases by 83.32% and 75.88% respectively in comparison to FIFO and 46.65% and 60.13% with respect to WFQ model. Similarly, in pressure sensor the improvements were 82.41% and 71.5% and 68.43% and 73.36% in comparison to FIFO and WFQ respectively. Data transmission were also improved in the Glucose sensor by 80.85% and 64.7% and 92.1% and 83.17% in comparison to FIFO and WFQ respectively. However, non-emergency cases data transmission using PFQ model was negatively impacted and scored higher rates than FIFO and WFQ since PFQ tends to give higher priority to emergency cases. Thus, a derivative from the PFQ model has been developed to create a new version namely “Priority Based-Fair Queuing-Tolerated Delay” (PFQ-TD) to balance the data transmission between emergency and non-emergency cases where tolerated delay in emergency cases has been considered. PFQ-TD has succeeded in balancing fairly this issue and reducing the total average delay and jitter of emergency and non-emergency cases in all sensors and keep them within the acceptable allowable standards. PFQ-TD has improved the overall average delay and jitter in emergency and non-emergency cases among all sensors by 41% and 84% respectively in comparison to PFQ model

    A comprehensive survey of wireless body area networks on PHY, MAC, and network layers solutions

    Get PDF
    Recent advances in microelectronics and integrated circuits, system-on-chip design, wireless communication and intelligent low-power sensors have allowed the realization of a Wireless Body Area Network (WBAN). A WBAN is a collection of low-power, miniaturized, invasive/non-invasive lightweight wireless sensor nodes that monitor the human body functions and the surrounding environment. In addition, it supports a number of innovative and interesting applications such as ubiquitous healthcare, entertainment, interactive gaming, and military applications. In this paper, the fundamental mechanisms of WBAN including architecture and topology, wireless implant communication, low-power Medium Access Control (MAC) and routing protocols are reviewed. A comprehensive study of the proposed technologies for WBAN at Physical (PHY), MAC, and Network layers is presented and many useful solutions are discussed for each layer. Finally, numerous WBAN applications are highlighted

    Instruction-set architecture synthesis for VLIW processors

    Get PDF

    EC-CENTRIC: An Energy- and Context-Centric Perspective on IoT Systems and Protocol Design

    Get PDF
    The radio transceiver of an IoT device is often where most of the energy is consumed. For this reason, most research so far has focused on low power circuit and energy efficient physical layer designs, with the goal of reducing the average energy per information bit required for communication. While these efforts are valuable per se, their actual effectiveness can be partially neutralized by ill-designed network, processing and resource management solutions, which can become a primary factor of performance degradation, in terms of throughput, responsiveness and energy efficiency. The objective of this paper is to describe an energy-centric and context-aware optimization framework that accounts for the energy impact of the fundamental functionalities of an IoT system and that proceeds along three main technical thrusts: 1) balancing signal-dependent processing techniques (compression and feature extraction) and communication tasks; 2) jointly designing channel access and routing protocols to maximize the network lifetime; 3) providing self-adaptability to different operating conditions through the adoption of suitable learning architectures and of flexible/reconfigurable algorithms and protocols. After discussing this framework, we present some preliminary results that validate the effectiveness of our proposed line of action, and show how the use of adaptive signal processing and channel access techniques allows an IoT network to dynamically tune lifetime for signal distortion, according to the requirements dictated by the application

    A novel energy-driven computing paradigm for e-health scenarios

    Get PDF
    A first-rate e-Health system saves lives, provides better patient care, allows complex but useful epidemiologic analysis and saves money. However, there may also be concerns about the costs and complexities associated with e-health implementation, and the need to solve issues about the energy footprint of the high-demanding computing facilities. This paper proposes a novel and evolved computing paradigm that: (i) provides the required computing and sensing resources; (ii) allows the population-wide diffusion; (iii) exploits the storage, communication and computing services provided by the Cloud; (iv) tackles the energy-optimization issue as a first-class requirement, taking it into account during the whole development cycle. The novel computing concept and the multi-layer top-down energy-optimization methodology obtain promising results in a realistic scenario for cardiovascular tracking and analysis, making the Home Assisted Living a reality

    A Probabilistic Approach for the System-Level Design of Multi-ASIP Platforms

    Get PDF

    Parallel programming in biomedical signal processing

    Get PDF
    Dissertação para obtenção do Grau de Mestre em Engenharia BiomédicaPatients with neuromuscular and cardiorespiratory diseases need to be monitored continuously. This constant monitoring gives rise to huge amounts of multivariate data which need to be processed as soon as possible, so that their most relevant features can be extracted. The field of parallel processing, an area from the computational sciences, comes naturally as a way to provide an answer to this problem. For the parallel processing to succeed it is necessary to adapt the pre-existing signal processing algorithms to the modern architectures of computer systems with several processing units. In this work parallel processing techniques are applied to biosignals, connecting the area of computer science to the biomedical domain. Several considerations are made on how to design parallel algorithms for signal processing, following the data parallel paradigm. The emphasis is given to algorithm design, rather than the computing systems that execute these algorithms. Nonetheless, shared memory systems and distributed memory systems are mentioned in the present work. Two signal processing tools integrating some of the parallel programming concepts mentioned throughout this work were developed. These tools allow a fast and efficient analysis of long-term biosignals. The two kinds of analysis are focused on heart rate variability and breath frequency, and aim to the processing of electrocardiograms and respiratory signals, respectively. The proposed tools make use of the several processing units that most of the actual computers include in their architecture, giving the clinician a fast tool without him having to set up a system specifically meant to run parallel programs
    corecore