13,144 research outputs found

    Postmortem iris recognition and its application in human identification

    Full text link
    Iris recognition is a validated and non-invasive human identification technology currently implemented for the purposes of surveillance and security (i.e. border control, schools, military). Similar to deoxyribonucleic acid (DNA), irises are a highly individualizing component of the human body. Based on a lack of genetic penetrance, irises are unique between an individual’s left and right iris and between identical twins, proving to be more individualizing than DNA. At this time, little to no research has been conducted on the use of postmortem iris scanning as a biometric measurement of identification. The purpose of this pilot study is to explore the use of iris recognition as a tool for postmortem identification. Objectives of the study include determining whether current iris recognition technology can locate and detect iris codes in postmortem globes, and if iris scans collected at different postmortem time intervals can be identified as the same iris initially enrolled. Data from 43 decedents involving 148 subsequent iris scans demonstrated a subsequent match rate of approximately 80%, supporting the theory that iris recognition technology is capable of detecting and identifying an individual’s iris code in a postmortem setting. A chi-square test of independence showed no significant difference between match outcomes and the globe scanned (left vs. right), and gender had no bearing on the match outcome. There was a significant relationship between iris color and match outcome, with blue/gray eyes yielding a lower match rate (59%) compared to brown (82%) or green/hazel eyes (88%), however, the sample size of blue/gray eyes in this study was not large enough to draw a meaningful conclusion. An isolated case involving an antemortem initial scan collected from an individual on life support yielded an accurate identification (match) with a subsequent scan captured at approximately 10 hours postmortem. Falsely rejected subsequent iris scans or "no match" results occurred in about 20% of scans; they were observed at each PMI range and varied from 19-30%. The false reject rate is too high to reliably establish non-identity when used alone and ideally would be significantly lower prior to implementation in a forensic setting; however, a "no match" could be confirmed using another method. Importantly, the data showed a false match rate or false accept rate (FAR) of zero, a result consistent with previous iris recognition studies in living individuals. The preliminary results of this pilot study demonstrate a plausible role for iris recognition in postmortem human identification. Implementation of a universal iris recognition database would benefit the medicolegal death investigation and forensic pathology communities, and has potential applications to other situations such as missing persons and human trafficking cases

    On Using Gait in Forensic Biometrics

    No full text
    Given the continuing advances in gait biometrics, it appears prudent to investigate the translation of these techniques for forensic use. We address the question as to the confidence that might be given between any two such measurements. We use the locations of ankle, knee and hip to derive a measure of the match between walking subjects in image sequences. The Instantaneous Posture Match algorithm, using Harr templates, kinematics and anthropomorphic knowledge is used to determine their location. This is demonstrated using real CCTV recorded at Gatwick Airport, laboratory images from the multi-view CASIA-B dataset and an example of real scene of crime video. To access the measurement confidence we study the mean intra- and inter-match scores as a function of database size. These measures converge to constant and separate values, indicating that the match measure derived from individual comparisons is considerably smaller than the average match measure from a population

    Binary object recognition system on FPGA with bSOM

    Get PDF
    Tri-state Self Organizing Map (bSOM), which takes binary inputs and maintains tri-state weights, has been used for classification rather than clustering in this paper. The major contribution here is the demonstration of the potential use of the modified bSOM in security surveillance, as a recognition system on FPGA

    On Acquisition and Analysis of a Dataset Comprising of Gait, Ear and Semantic data

    No full text
    In outdoor scenarios such as surveillance where there is very little control over the environments, complex computer vision algorithms are often required for analysis. However constrained environments, such as walkways in airports where the surroundings and the path taken by individuals can be controlled, provide an ideal application for such systems. Figure 1.1 depicts an idealised constrained environment. The path taken by the subject is restricted to a narrow path and once inside is in a volume where lighting and other conditions are controlled to facilitate biometric analysis. The ability to control the surroundings and the flow of people greatly simplifes the computer vision task, compared to typical unconstrained environments. Even though biometric datasets with greater than one hundred people are increasingly common, there is still very little known about the inter and intra-subject variation in many biometrics. This information is essential to estimate the recognition capability and limits of automatic recognition systems. In order to accurately estimate the inter- and the intra- class variance, substantially larger datasets are required [40]. Covariates such as facial expression, headwear, footwear type, surface type and carried items are attracting increasing attention; although considering the potentially large impact on an individuals biometrics, large trials need to be conducted to establish how much variance results. This chapter is the first description of the multibiometric data acquired using the University of Southampton's Multi-Biometric Tunnel [26, 37]; a biometric portal using automatic gait, face and ear recognition for identification purposes. The tunnel provides a constrained environment and is ideal for use in high throughput security scenarios and for the collection of large datasets. We describe the current state of data acquisition of face, gait, ear, and semantic data and present early results showing the quality and range of data that has been collected. The main novelties of this dataset in comparison with other multi-biometric datasets are: 1. gait data exists for multiple views and is synchronised, allowing 3D reconstruction and analysis; 2. the face data is a sequence of images allowing for face recognition in video; 3. the ear data is acquired in a relatively unconstrained environment, as a subject walks past; and 4. the semantic data is considerably more extensive than has been available previously. We shall aim to show the advantages of this new data in biometric analysis, though the scope for such analysis is considerably greater than time and space allows for here
    corecore