1,793 research outputs found

    Processing Polysomnographic Signals, using Independent Component Analysis

    No full text
    International audienceIn this paper several applications of the Independent Component Analysis (ICA) algorithm, for the analysis of biomedical signal recordings have been investigated. One of these applications is the removal of EEG artifacts such as the EOG. It is shown that ICA may serve as a powerful tool, which could help the analysis of biomedical recordings, and give better insights about the underlying sources of some disorders. Another application of the proposed method is the detection of sleep disorders in patients suffering from sleep apnea. The ultimate goal of this approach is to develop an automatic noninvasive data acquisition system, for clinical applications

    Online Alpha Wave detector: an Embedded hardware-software implementation

    Get PDF
    The recent trend on embedded system development opens a new prospect for applications that in the past were not possible. The eye tracking for sleep and fatigue detection has become an important and useful application in industrial and automotive scenarios since fatigue is one of the most prevalent causes of earth-moving equipment accidents. Typical applications such as cameras, accelerometers and dermal analyzers are present on the market but have some inconvenient. This thesis project has used EEG signal, particularly, alpha waves, to overcome them by using an embedded software-hardware implementation to detect these signals in real tim

    Analysis of Small Muscle Movement Effects on EEG Signals

    Get PDF
    In this thesis, the artefactual effects of the small muscle movements were investigated. Upper frequency bands (30 Hz) of the EEG signal were extracted in order to investigate the artefactual effects of the small muscle movements. When the contamination level is high, the detection of the small muscle artifact can be made with the 92.2% accuracy. If these artifacts are really small such as a single finger movement, the detection accuracy decreases to 64%. But, the detection accuracy increases to 72% after removing the eye blink artifacts. The results of the classification support our hypothesis about the artefactual effects of the small muscle movements

    Artifact Removal Methods in EEG Recordings: A Review

    Get PDF
    To obtain the correct analysis of electroencephalogram (EEG) signals, non-physiological and physiological artifacts should be removed from EEG signals. This study aims to give an overview on the existing methodology for removing physiological artifacts, e.g., ocular, cardiac, and muscle artifacts. The datasets, simulation platforms, and performance measures of artifact removal methods in previous related research are summarized. The advantages and disadvantages of each technique are discussed, including regression method, filtering method, blind source separation (BSS), wavelet transform (WT), empirical mode decomposition (EMD), singular spectrum analysis (SSA), and independent vector analysis (IVA). Also, the applications of hybrid approaches are presented, including discrete wavelet transform - adaptive filtering method (DWT-AFM), DWT-BSS, EMD-BSS, singular spectrum analysis - adaptive noise canceler (SSA-ANC), SSA-BSS, and EMD-IVA. Finally, a comparative analysis for these existing methods is provided based on their performance and merits. The result shows that hybrid methods can remove the artifacts more effectively than individual methods

    The effect of electronic word of mouth communication on purchase intention moderate by trust: a case online consumer of Bahawalpur Pakistan

    Get PDF
    The aim of this study is concerned with improving the previous research finding complete filling the research gaps and introducing the e-WOM on purchase intention and brand trust as a moderator between the e-WOM, and purchase intention an online user in Bahawalpur city Pakistan, therefore this study was a focus at linking the research gap of previous literature of past study based on individual awareness from the real-life experience. we collected data from the online user of the Bahawalpur Pakistan. In this study convenience sampling has been used to collect data and instruments of this study adopted from the previous study. The quantitative research methodology used to collect data, survey method was used to assemble data for this study, 300 questionnaire were distributed in Bahawalpur City due to the ease, reliability, and simplicity, effective recovery rate of 67% as a result 202 valid response was obtained for the effect of e-WOM on purchase intention and moderator analysis has been performed. Hypotheses of this research are analyzed by using Structural Equation Modeling (SEM) based on Partial Least Square (PLS). The result of this research is e-WOM significantly positive effect on purchase intention and moderator role of trust significantly affects the relationship between e-WOM, and purchase intention. The addition of brand trust in the model has contributed to the explanatory power, some studied was conduct on brand trust as a moderator and this study has contributed to the literature in this favor. significantly this study focused on current marketing research. Unlike past studies focused on western context, this study has extended the regional literature on e-WOM, and purchase intention to be intergrading in Bahawalpur Pakistan context. Lastly, future studies are recommended to examine the effect of trust in other countries allow for the comparison of the findings

    Comparative analysis of TMS-EEG signal using different approaches in healthy subjects

    Get PDF
    openThe integration of transcranial magnetic stimulation with electroencephalography (TMS-EEG) represents a useful non-invasive approach to assess cortical excitability, plasticity and intra-cortical connectivity in humans in physiological and pathological conditions. However, biological and environmental noise sources can contaminate the TMS-evoked potentials (TEPs). Therefore, signal preprocessing represents a fundamental step in the analysis of these potentials and is critical to remove artefactual components while preserving the physiological brain activity. The objective of the present study is to evaluate the effects of different signal processing pipelines, (namely Leodori et al., Rogasch et al., Mutanen et al.) applied on TEPs recorded in five healthy volunteers after TMS stimulation of the primary motor cortex (M1) of the dominant hemisphere. These pipelines were used and compared to remove artifacts and improve the quality of the recorded signals, laying the foundation for subsequent analyses. Various algorithms, such as Independent Component Analysis (ICA), SOUND, and SSP-SIR, were used in each pipeline. Furthermore, after signal preprocessing, current localization was performed to map the TMS-induced neural activation in the cortex. This methodology provided valuable information on the spatial distribution of activity and further validated the effectiveness of the signal cleaning pipelines. Comparing the effects of the different pipelines on the same dataset, we observed considerable variability in how the pipelines affect various signal characteristics. We observed significant differences in the effects on signal amplitude and in the identification and characterisation of peaks of interest, i.e., P30, N45, P60, N100, P180. The identification and characteristics of these peaks showed variability, especially with regard to the early peaks, which reflect the cortical excitability of the stimulated area and are the more affected by biological and stimulation-related artifacts. Despite these differences, the topographies and source localisation, which are the most informative and useful in reconstructing signal dynamics, were consistent and reliable between the different pipelines considered. The results suggest that the existing methodologies for analysing TEPs produce different effects on the data, but are all capable of reproducing the dynamics of the signal and its components. Future studies evaluating different signal preprocessing methods in larger populations are needed to determine an appropriate workflow that can be shared through the scientific community, in order to make the results obtained in different centres comparable

    Motion Artifacts Correction from Single-Channel EEG and fNIRS Signals using Novel Wavelet Packet Decomposition in Combination with Canonical Correlation Analysis

    Full text link
    The electroencephalogram (EEG) and functional near-infrared spectroscopy (fNIRS) signals, highly non-stationary in nature, greatly suffers from motion artifacts while recorded using wearable sensors. This paper proposes two robust methods: i) Wavelet packet decomposition (WPD), and ii) WPD in combination with canonical correlation analysis (WPD-CCA), for motion artifact correction from single-channel EEG and fNIRS signals. The efficacy of these proposed techniques is tested using a benchmark dataset and the performance of the proposed methods is measured using two well-established performance matrices: i) Difference in the signal to noise ratio ({\Delta}SNR) and ii) Percentage reduction in motion artifacts ({\eta}). The proposed WPD-based single-stage motion artifacts correction technique produces the highest average {\Delta}SNR (29.44 dB) when db2 wavelet packet is incorporated whereas the greatest average {\eta} (53.48%) is obtained using db1 wavelet packet for all the available 23 EEG recordings. Our proposed two-stage motion artifacts correction technique i.e. the WPD-CCA method utilizing db1 wavelet packet has shown the best denoising performance producing an average {\Delta}SNR and {\eta} values of 30.76 dB and 59.51%, respectively for all the EEG recordings. On the other hand, the two-stage motion artifacts removal technique i.e. WPD-CCA has produced the best average {\Delta}SNR (16.55 dB, utilizing db1 wavelet packet) and largest average {\eta} (41.40%, using fk8 wavelet packet). The highest average {\Delta}SNR and {\eta} using single-stage artifacts removal techniques (WPD) are found as 16.11 dB and 26.40%, respectively for all the fNIRS signals using fk4 wavelet packet. In both EEG and fNIRS modalities, the percentage reduction in motion artifacts increases by 11.28% and 56.82%, respectively when two-stage WPD-CCA techniques are employed.Comment: 25 pages, 10 figures and 2 table

    Brain Dynamics Based Automated Epileptic Seizure Detection

    Get PDF
    abstract: Approximately 1% of the world population suffers from epilepsy. Continuous long-term electroencephalographic (EEG) monitoring is the gold-standard for recording epileptic seizures and assisting in the diagnosis and treatment of patients with epilepsy. However, this process still requires that seizures are visually detected and marked by experienced and trained electroencephalographers. The motivation for the development of an automated seizure detection algorithm in this research was to assist physicians in such a laborious, time consuming and expensive task. Seizures in the EEG vary in duration (seconds to minutes), morphology and severity (clinical to subclinical, occurrence rate) within the same patient and across patients. The task of seizure detection is also made difficult due to the presence of movement and other recording artifacts. An early approach towards the development of automated seizure detection algorithms utilizing both EEG changes and clinical manifestations resulted to a sensitivity of 70-80% and 1 false detection per hour. Approaches based on artificial neural networks have improved the detection performance at the cost of algorithm's training. Measures of nonlinear dynamics, such as Lyapunov exponents, have been applied successfully to seizure prediction. Within the framework of this MS research, a seizure detection algorithm based on measures of linear and nonlinear dynamics, i.e., the adaptive short-term maximum Lyapunov exponent (ASTLmax) and the adaptive Teager energy (ATE) was developed and tested. The algorithm was tested on long-term (0.5-11.7 days) continuous EEG recordings from five patients (3 with intracranial and 2 with scalp EEG) and a total of 56 seizures, producing a mean sensitivity of 93% and mean specificity of 0.048 false positives per hour. The developed seizure detection algorithm is data-adaptive, training-free and patient-independent. It is expected that this algorithm will assist physicians in reducing the time spent on detecting seizures, lead to faster and more accurate diagnosis, better evaluation of treatment, and possibly to better treatments if it is incorporated on-line and real-time with advanced neuromodulation therapies for epilepsy.Dissertation/ThesisM.S. Electrical Engineering 201
    • …
    corecore