1,904 research outputs found

    Automatic Mode Switching in Atrial Fibrillation

    Get PDF
    Automatic mode switching (AMS) algorithms were designed to prevent tracking of atrial tachyarrhythmias (ATA) or other rapidly occurring signals sensed by atrial channels, thereby reducing the adverse hemodynamic and symptomatic consequences of a rapid ventricular response. The inclusion of an AMS function in most dual chamber pacemaker now provides optimal management of atrial arrhythmias and allows the benefit of atrioventricular synchrony to be extended to a population with existing atrial fibrillation. Appropriate AMS depends on several parameters: a) the programmed parameters; b) the characteristics of the arrhythmia; c) the characteristics of the AMS algorithm. Three qualifying aspects constitute an AMS algorithm: onset, AMS response, and resynchronization. Since AMS programs also provide data on the time of onset and duration of AMS episodes, AMS data may be interpreted as a surrogate marker of ATAs recurrence. Recently, stored electrograms corresponding to episodes of ATAs have been introduced, thus clarifying the accuracy of AMS in detecting ATAs Clinically this information may be used to assess the efficacy of an antiarrhythmic intervention or the risk of thromboembolic events, and it may serve as a valuable research tool for evaluating the natural history and burden of ATAs

    Pacemaker Prevention Therapy in Drug–refractory Paroxysmal Atrial Fibrillation: Reliability of Diagnostics and Effectiveness of Prevention Pacing Therapy in Vitatron™ Selection® device

    Get PDF
    Introduction. Atrial fibrillation (AF), the most common and rising disorder of cardiac rhythm, is quite difficult to control and/or to treat. Non pharmacological therapies for AF may involve the use of dedicated pacing algorithms to detect and prevent atrial arrhythmia that could be a trigger for AF onset. Selection 900E/AF2.0 Vitatron DDDRP pacemaker (1) keeps an atrial arrhythmia diary thus providing detailed onset reports of arrhythmias of interest, (2) provides us data about the number of premature atrial contractions (PACs) and (3) plots heart rate in the 5 minutes preceding the detection of an atrial arrhythmia. Moreover, this device applies four dedicated pacing therapies to reduce the incidence of atrial arrhythmia and AF events. Aim of the Study. To analyze the reliability to record atrial arrhythmias and evaluate effectiveness of its AF preventive pacing therapies. Material and Methods. We enrolled 15 patients (9 males and 6 females, mean age of 71±5 years, NYHA class I–II), with a DDDRP pacemaker implanted for a “bradycardia–tachycardia” syndrome, with advanced atrioventricular conduction disturbances. We compared the number and duration of AF episodes’ stored in the device with a contemporaneous 24h Holter monitoring. After that, we switched on the atrial arrhythmias detecting algorithms, starting from an atrial rate over 180 beats per minute for at least 6 ventricular cycles, and ending with at least 10 ventricular cycles in sinus rhythm. Thereafter, in order to evaluate the possible reduction in PACs number and in number and duration of AF episodes, we tailored all the four pacing preventive algorithms. Patients were followed for 24±8 months (from 20 to 32 months). Results. All 59 atrial arrhythmia episodes occurred in the first part of this trial, were correctly recorded by both systems, with a correlation coefficient (r) of 0.96. During the follow–up, we observed a significant reduction not only in PACs number (from 83±12/day to 2.3±0.8/day) but also in AF episodes (from 46±7/day to 0.12±0.03/day) and AF burden (from 93%±6% to 0.3%±0.06%). An increase in atrial pacing percentages (from 3%±0.5% to 97%±3%) was also contemporaneously observed. Conclusion. In this pacemaker, detection of atrial arrhythmia episodes is highly reliable, thus making available an appropriate monitoring of heart rhythm, mainly suitable in AF asymptomatic patients. Moreover, the significant reduction of atrial arrhythmia episodes indicates that this might represent a suitable therapeutic option for an effective preventive therapy of AF in paced brady–tachy patients

    Advances in Digital Processing of Low-Amplitude Components of Electrocardiosignals

    Get PDF
    This manual has been published within the framework of the BME-ENA project under the responsibility of National Technical University of Ukraine. The BME-ENA “Biomedical Engineering Education Tempus Initiative in Eastern Neighbouring Area”, Project Number: 543904-TEMPUS-1-2013-1-GR-TEMPUS-JPCR is a Joint Project within the TEMPUS IV program. This project has been funded with support from the European Commission.Навчальний посібник присвячено розробці методів та засобів для неінвазивного виявлення та дослідження тонких проявів електричної активності серця. Особлива увага приділяється вдосконаленню інформаційного та алгоритмічного забезпечення систем електрокардіографії високого розрізнення для ранньої діагностики електричної нестабільності міокарда, а також для оцінки функціонального стану плоду під час вагітності. Теоретичні основи супроводжуються прикладами реалізації алгоритмів за допомогою системи MATLAB. Навчальний посібник призначений для студентів, аспірантів, а також фахівців у галузі біомедичної електроніки та медичних працівників.The teaching book is devoted to development and research of methods and tools for non-invasive detection of subtle manifistations of heart electrical activity. Particular attention is paid to the improvement of information and algorithmic support of high resolution electrocardiography for early diagnosis of myocardial electrical instability, as well as for the evaluation of the functional state of the fetus during pregnancy examination. The theoretical basis accompanied by the examples of implementation of the discussed algorithms with the help of MATLAB. The teaching book is intended for students, graduate students, as well as specialists in the field of biomedical electronics and medical professionals

    Electrocardiographic Troubleshooting of Implanted Cardiac Electronic Devices

    Get PDF

    Automatic mode switching in atrial fibrillation

    Get PDF
    Automatic mode switching (AMS) algorithms were designed to prevent tracking of atrial tachyarrhythmias (ATA) or other rapidly occurring signals sensed by atrial channels, thereby reducing the adverse hemodynamic and symptomatic consequences of a rapid ventricular response. The inclusion of an AMS function in most dual chamber pacemaker now provides optimal management of atrial arrhythmias and allows the benefit of atrioventricular synchrony to be extended to a population with existing atrial fibrillation. Appropriate AMS depends on several parameters: a) the programmed parameters; b) the characteristics of the arrhythmia; c) the characteristics of the AMS algorithm. Three qualifying aspects constitute an AMS algorithm: onset, AMS response, and resynchronization. Since AMS programs also provide data on the time of onset and duration of AMS episodes, AMS data may be interpreted as a surrogate marker of ATAs recurrence. Recently, stored electrograms corresponding to episodes of ATAs have been introduced, thus clarifying the accuracy of AMS in detecting ATAs Clinically this information may be used to assess the efficacy of an antiarrhythmic intervention or the risk of thromboembolic events, and it may serve as a valuable research tool for evaluating the natural history and burden of ATAs

    Electrocardiogram data collection under network attacks on the MAC platform

    Get PDF
    Increasing heart disease among human beings needs more precise treatment, which requires monitoring of electrocardiogram (ECG). In many cases, real time monitoring of ECG is needed via wireless or wireline networks. Use of network-connected computers for monitoring proposes can raise security issues, which can be created by viruses, worms, or external agents such as DoS attack traffic. Any alteration of this biomedical signal can lead to wrong diagnosis and wrong treatment. Furthermore, in healthcare industry, HIPAA rules require health information to be kept secure by providing confidentiality, integrity, and availability. This thesis investigates how integrity and availability of remotely monitored ECG signals can be affected silently due to adverse network conditions, hence raising false alarms. In this thesis, components of monitored ECG signals under adverse network conditions are measured and compared against normal ECG signals for detection of different heart diseases

    Pacemaker and ICD Troubleshooting

    Get PDF
    Continuous advancements in technology and software algorithms for pacemakers and implantable cardioverter‐defibrillators (ICDs) have improved functional reliability and broadened their diagnostic capabilities. At the same time, understanding management and troubleshooting of modern devices has become increasingly complex for the device implanter. This chapter provides an overview of the underlying physics and basic principles important to pacemaker and ICD function. The second part of this chapter outlines common device problems encountered in patients with pacemakers and ICDs and provides solutions and tips for troubleshooting

    Extending the honey bee venome with the antimicrobial peptide apidaecin and a protein resembling wasp antigen 5

    Get PDF
    Honey bee venom is a complex mixture of toxic proteins and peptides. In the present study we tried to extend our knowledge of the venom composition using two different approaches. First, worker venom was analysed by liquid chromatography-mass spectrometry and this revealed the antimicrobial peptide apidaecin for the first time in such samples. Its expression in the venom gland was confirmed by reverse transcription PCR and by a peptidomic analysis of the venom apparatus tissue. Second, genome mining revealed a list of proteins with resemblance to known insect allergens or venom toxins, one of which showed homology to proteins of the antigen 5 (Ag5)/Sol i 3 cluster. It was demonstrated that the honey bee Ag5-like gene is expressed by venom gland tissue of winter bees but not of summer bees. Besides this seasonal variation, it shows an interesting spatial expression pattern with additional production in the hypopharyngeal glands, the brains and the midgut. Finally, our immunoblot study revealed that both synthetic apidaecin and the Ag5-like recombinant from bacteria evoke no humoral activity in beekeepers. Also, no IgG4-based cross-reactivity was detected between the honey bee Ag5-like protein and its yellow jacket paralogue Ves v 5