    Adaptive scan strategies for fetal MRI imaging using slice to volume techniques

    Get PDF
    © 2015 IEEE.In this paper several novel methods to account for fetal movements during fetal Magnetic Resonance Imaging (fetal MRI) are explored. We show how slice-to-volume reconstruction methods can be used to account for motion adaptively during the scan. Three candidate methods are tested for their feasibility and integrated into a computer simulation of fetal MRI. The first alters the main orientation of the stacks used for reconstruction, the second stops if too much motion occurs during slice acquisition and the third steers the orientation of each slice individually. Reconstruction informed adaptive scanning can provide a peak signal-to-noise ratio (PSNR) improvement of up to 2 dB after only two stacks of scanned slices and is more efficient with respect to the uncertainty of the final reconstruction

    PVR: Patch-to-Volume Reconstruction for Large Area Motion Correction of Fetal MRI

    Get PDF
    In this paper we present a novel method for the correction of motion artifacts that are present in fetal Magnetic Resonance Imaging (MRI) scans of the whole uterus. Contrary to current slice-to-volume registration (SVR) methods, requiring an inflexible anatomical enclosure of a single investigated organ, the proposed patch-to-volume reconstruction (PVR) approach is able to reconstruct a large field of view of non-rigidly deforming structures. It relaxes rigid motion assumptions by introducing a specific amount of redundant information that is exploited with parallelized patch-wise optimization, super-resolution, and automatic outlier rejection. We further describe and provide an efficient parallel implementation of PVR allowing its execution within reasonable time on commercially available graphics processing units (GPU), enabling its use in the clinical practice. We evaluate PVR's computational overhead compared to standard methods and observe improved reconstruction accuracy in presence of affine motion artifacts of approximately 30% compared to conventional SVR in synthetic experiments. Furthermore, we have evaluated our method qualitatively and quantitatively on real fetal MRI data subject to maternal breathing and sudden fetal movements. We evaluate peak-signal-to-noise ratio (PSNR), structural similarity index (SSIM), and cross correlation (CC) with respect to the originally acquired data and provide a method for visual inspection of reconstruction uncertainty. With these experiments we demonstrate successful application of PVR motion compensation to the whole uterus, the human fetus, and the human placenta.Comment: 10 pages, 13 figures, submitted to IEEE Transactions on Medical Imaging. v2: wadded funders acknowledgements to preprin

    Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates

    Get PDF
    The study of cerebral anatomy in developing neonates is of great importance for the understanding of brain development during the early period of life. This dissertation therefore focuses on three challenges in the modelling of cerebral anatomy in neonates during brain development. The methods that have been developed all use Magnetic Resonance Images (MRI) as source data. To facilitate study of vascular development in the neonatal period, a set of image analysis algorithms are developed to automatically extract and model cerebral vessel trees. The whole process consists of cerebral vessel tracking from automatically placed seed points, vessel tree generation, and vasculature registration and matching. These algorithms have been tested on clinical Time-of- Flight (TOF) MR angiographic datasets. To facilitate study of the neonatal cortex a complete cerebral cortex segmentation and reconstruction pipeline has been developed. Segmentation of the neonatal cortex is not effectively done by existing algorithms designed for the adult brain because the contrast between grey and white matter is reversed. This causes pixels containing tissue mixtures to be incorrectly labelled by conventional methods. The neonatal cortical segmentation method that has been developed is based on a novel expectation-maximization (EM) method with explicit correction for mislabelled partial volume voxels. Based on the resulting cortical segmentation, an implicit surface evolution technique is adopted for the reconstruction of the cortex in neonates. The performance of the method is investigated by performing a detailed landmark study. To facilitate study of cortical development, a cortical surface registration algorithm for aligning the cortical surface is developed. The method first inflates extracted cortical surfaces and then performs a non-rigid surface registration using free-form deformations (FFDs) to remove residual alignment. Validation experiments using data labelled by an expert observer demonstrate that the method can capture local changes and follow the growth of specific sulcus

    A Survey on Deep Learning in Medical Image Analysis

    Full text link
    Deep learning algorithms, in particular convolutional networks, have rapidly become a methodology of choice for analyzing medical images. This paper reviews the major deep learning concepts pertinent to medical image analysis and summarizes over 300 contributions to the field, most of which appeared in the last year. We survey the use of deep learning for image classification, object detection, segmentation, registration, and other tasks and provide concise overviews of studies per application area. Open challenges and directions for future research are discussed.Comment: Revised survey includes expanded discussion section and reworked introductory section on common deep architectures. Added missed papers from before Feb 1st 201

    Volumetric MRI Reconstruction from 2D Slices in the Presence of Motion

    Get PDF
    Despite recent advances in acquisition techniques and reconstruction algorithms, magnetic resonance imaging (MRI) remains challenging in the presence of motion. To mitigate this, ultra-fast two-dimensional (2D) MRI sequences are often used in clinical practice to acquire thick, low-resolution (LR) 2D slices to reduce in-plane motion. The resulting stacks of thick 2D slices typically provide high-quality visualizations when viewed in the in-plane direction. However, the low spatial resolution in the through-plane direction in combination with motion commonly occurring between individual slice acquisitions gives rise to stacks with overall limited geometric integrity. In further consequence, an accurate and reliable diagnosis may be compromised when using such motion-corrupted, thick-slice MRI data. This thesis presents methods to volumetrically reconstruct geometrically consistent, high-resolution (HR) three-dimensional (3D) images from motion-corrupted, possibly sparse, low-resolution 2D MR slices. It focuses on volumetric reconstructions techniques using inverse problem formulations applicable to a broad field of clinical applications in which associated motion patterns are inherently different, but the use of thick-slice MR data is current clinical practice. In particular, volumetric reconstruction frameworks are developed based on slice-to-volume registration with inter-slice transformation regularization and robust, complete-outlier rejection for the reconstruction step that can either avoid or efficiently deal with potential slice-misregistrations. Additionally, this thesis describes efficient Forward-Backward Splitting schemes for image registration for any combination of differentiable (not necessarily convex) similarity measure and convex (not necessarily smooth) regularization with a tractable proximal operator. Experiments are performed on fetal and upper abdominal MRI, and on historical, printed brain MR films associated with a uniquely long-term study dating back to the 1980s. The results demonstrate the broad applicability of the presented frameworks to achieve robust reconstructions with the potential to improve disease diagnosis and patient management in clinical practice

    Complex diffusion-weighted image estimation via matrix recovery under general noise models

    Get PDF
    We propose a patch-based singular value shrinkage method for diffusion magnetic resonance image estimation targeted at low signal to noise ratio and accelerated acquisitions. It operates on the complex data resulting from a sensitivity encoding reconstruction, where asymptotically optimal signal recovery guarantees can be attained by modeling the noise propagation in the reconstruction and subsequently simulating or calculating the limit singular value spectrum. Simple strategies are presented to deal with phase inconsistencies and optimize patch construction. The pertinence of our contributions is quantitatively validated on synthetic data, an in vivo adult example, and challenging neonatal and fetal cohorts. Our methodology is compared with related approaches, which generally operate on magnitude-only data and use data-based noise level estimation and singular value truncation. Visual examples are provided to illustrate effectiveness in generating denoised and debiased diffusion estimates with well preserved spatial and diffusion detail.Comment: 26 pages, 9 figure

    Motion robust acquisition and reconstruction of quantitative T2* maps in the developing brain

    Get PDF
    The goal of the research presented in this thesis was to develop methods for quantitative T2* mapping of the developing brain. Brain maturation in the early period of life involves complex structural and physiological changes caused by synaptogenesis, myelination and growth of cells. Molecular structures and biological processes give rise to varying levels of T2* relaxation time, which is an inherent contrast mechanism in magnetic resonance imaging. The knowledge of T2* relaxation times in the brain can thus help with evaluation of pathology by establishing its normative values in the key areas of the brain. T2* relaxation values are a valuable biomarker for myelin microstructure and iron concentration, as well as an important guide towards achievement of optimal fMRI contrast. However, fetal MR imaging is a significant step up from neonatal or adult MR imaging due to the complexity of the acquisition and reconstruction techniques that are required to provide high quality artifact-free images in the presence of maternal respiration and unpredictable fetal motion. The first contribution of this thesis, described in Chapter 4, presents a novel acquisition method for measurement of fetal brain T2* values. At the time of publication, this was the first study of fetal brain T2* values. Single shot multi-echo gradient echo EPI was proposed as a rapid method for measuring fetal T2* values by effectively freezing intra-slice motion. The study concluded that fetal T2* values are higher than those previously reported for pre-term neonates and decline with a consistent trend across gestational age. The data also suggested that longer than usual echo times or direct T2* measurement should be considered when performing fetal fMRI in order to reach optimal BOLD sensitivity. For the second contribution, described in Chapter 5, measurements were extended to a higher field strength of 3T and reported, for the first time, both for fetal and neonatal subjects at this field strength. The technical contribution of this work is a fully automatic segmentation framework that propagates brain tissue labels onto the acquired T2* maps without the need for manual intervention. The third contribution, described in Chapter 6, proposed a new method for performing 3D fetal brain reconstruction where the available data is sparse and is therefore limited in the use of current state of the art techniques for 3D brain reconstruction in the presence of motion. To enable a high resolution reconstruction, a generative adversarial network was trained to perform image to image translation between T2 weighted and T2* weighted data. Translated images could then be served as a prior for slice alignment and super resolution reconstruction of 3D brain image.Open Acces
    • …
    corecore