106,939 research outputs found
Detail Enhancement for Infrared Images Based on Propagated Image Filter
For displaying high-dynamic-range images acquired by thermal camera systems, 14-bit raw infrared data should map into 8-bit gray values. This paper presents a new method for detail enhancement of infrared images to display the image with a relatively satisfied contrast and brightness, rich detail information, and no artifacts caused by the image processing. We first adopt a propagated image filter to smooth the input image and separate the image into the base layer and the detail layer. Then, we refine the base layer by using modified histogram projection for compressing. Meanwhile, the adaptive weights derived from the layer decomposition processing are used as the strict gain control for the detail layer. The final display result is obtained by recombining the two modified layers. Experimental results on both cooled and uncooled infrared data verify that the proposed method outperforms the method based on log-power histogram modification and bilateral filter-based detail enhancement in both detail enhancement and visual effect
Deep-tissue focal fluorescence imaging with digitally time-reversed ultrasound-encoded light.
Fluorescence imaging is one of the most important research tools in biomedical sciences. However, scattering of light severely impedes imaging of thick biological samples beyond the ballistic regime. Here we directly show focusing and high-resolution fluorescence imaging deep inside biological tissues by digitally time-reversing ultrasound-tagged light with high optical gain (~5×10(5)). We confirm the presence of a time-reversed optical focus along with a diffuse background-a corollary of partial phase conjugation-and develop an approach for dynamic background cancellation. To illustrate the potential of our method, we image complex fluorescent objects and tumour microtissues at an unprecedented depth of 2.5 mm in biological tissues at a lateral resolution of 36 μm×52 μm and an axial resolution of 657 μm. Our results set the stage for a range of deep-tissue imaging applications in biomedical research and medical diagnostics
Streaming Video over HTTP with Consistent Quality
In conventional HTTP-based adaptive streaming (HAS), a video source is
encoded at multiple levels of constant bitrate representations, and a client
makes its representation selections according to the measured network
bandwidth. While greatly simplifying adaptation to the varying network
conditions, this strategy is not the best for optimizing the video quality
experienced by end users. Quality fluctuation can be reduced if the natural
variability of video content is taken into consideration. In this work, we
study the design of a client rate adaptation algorithm to yield consistent
video quality. We assume that clients have visibility into incoming video
within a finite horizon. We also take advantage of the client-side video
buffer, by using it as a breathing room for not only network bandwidth
variability, but also video bitrate variability. The challenge, however, lies
in how to balance these two variabilities to yield consistent video quality
without risking a buffer underrun. We propose an optimization solution that
uses an online algorithm to adapt the video bitrate step-by-step, while
applying dynamic programming at each step. We incorporate our solution into
PANDA -- a practical rate adaptation algorithm designed for HAS deployment at
scale.Comment: Refined version submitted to ACM Multimedia Systems Conference
(MMSys), 201
Flexible structure control laboratory development and technology demonstration
An experimental structure is described which was constructed to demonstrate and validate recent emerging technologies in the active control and identification of large flexible space structures. The configuration consists of a large, 20 foot diameter antenna-like flexible structure in the horizontal plane with a gimballed central hub, a flexible feed-boom assembly hanging from the hub, and 12 flexible ribs radiating outward. Fourteen electrodynamic force actuators mounted to the hub and to the individual ribs provide the means to excite the structure and exert control forces. Thirty permanently mounted sensors, including optical encoders and analog induction devices provide measurements of structural response at widely distributed points. An experimental remote optical sensor provides sixteen additional sensing channels. A computer samples the sensors, computes the control updates and sends commands to the actuators in real time, while simultaneously displaying selected outputs on a graphics terminal and saving them in memory. Several control experiments were conducted thus far and are documented. These include implementation of distributed parameter system control, model reference adaptive control, and static shape control. These experiments have demonstrated the successful implementation of state-of-the-art control approaches using actual hardware
Speeding up liquid crystal SLMs using overdrive with phase change reduction
Nematic liquid crystal spatial light modulators (SLMs) with fast switching times and high diffraction efficiency are important to various applications ranging from optical beam steering and adaptive optics to optical tweezers. Here we demonstrate the great benefits that can be derived in terms of speed enhancement without loss of diffraction efficiency from two mutually compatible approaches. The first technique involves the idea of overdrive, that is the calculation of intermediate patterns to speed up the transition to the target phase pattern. The second concerns optimization of the target pattern to reduce the required phase change applied to each pixel, which in addition leads to a substantial reduction of variations in the intensity of the diffracted light during the transition. When these methods are applied together, we observe transition times for the diffracted light fields of about 1 ms, which represents up to a tenfold improvement over current approaches. We experimentally demonstrate the improvements of the approach for applications such as holographic image projection, beam steering and switching, and real-time control loops
A Neuromorphic Model for Achromatic and Chromatic Surface Representation of Natural Images
This study develops a neuromorphic model of human lightness perception that is inspired by how the mammalian visual system is designed for this function. It is known that biological visual representations can adapt to a billion-fold change in luminance. How such a system determines absolute lightness under varying illumination conditions to generate a consistent interpretation of surface lightness remains an unsolved problem. Such a process, called "anchoring" of lightness, has properties including articulation, insulation, configuration, and area effects. The model quantitatively simulates such psychophysical lightness data, as well as other data such as discounting the illuminant, the double brilliant illusion, and lightness constancy and contrast effects. The model retina embodies gain control at retinal photoreceptors, and spatial contrast adaptation at the negative feedback circuit between mechanisms that model the inner segment of photoreceptors and interacting horizontal cells. The model can thereby adjust its sensitivity to input intensities ranging from dim moonlight to dazzling sunlight. A new anchoring mechanism, called the Blurred-Highest-Luminance-As-White (BHLAW) rule, helps simulate how surface lightness becomes sensitive to the spatial scale of objects in a scene. The model is also able to process natural color images under variable lighting conditions, and is compared with the popular RETINEX model.Air Force Office of Scientific Research (F496201-01-1-0397); Defense Advanced Research Project and the Office of Naval Research (N00014-95-0409, N00014-01-1-0624
ShaneAO: wide science spectrum adaptive optics system for the Lick Observatory
A new high-order adaptive optics system is now being commissioned at the Lick
Observatory Shane 3-meter telescope in California. This system uses a high
return efficiency sodium beacon and a combination of low and high-order
deformable mirrors to achieve diffraction-limited imaging over a wide spectrum
of infrared science wavelengths covering 0.8 to 2.2 microns. We present the
design performance goals and the first on-sky test results. We discuss several
innovations that make this system a pathfinder for next generation AO systems.
These include a unique woofer-tweeter control that provides full dynamic range
correction from tip/tilt to 16 cycles, variable pupil sampling wavefront
sensor, new enhanced silver coatings developed at UC Observatories that improve
science and LGS throughput, and tight mechanical rigidity that enables a
multi-hour diffraction- limited exposure in LGS mode for faint object
spectroscopy science.Comment: 11 pages, 10 figures. Presented at SPIE Astronomical Telescopes +
Instrumentation conference, paper 9148-7
Autofluorescence lifetime augmented reality as a means for real-time robotic surgery guidance in human patients.
Due to loss of tactile feedback the assessment of tumor margins during robotic surgery is based only on visual inspection, which is neither significantly sensitive nor specific. Here we demonstrate time-resolved fluorescence spectroscopy (TRFS) as a novel technique to complement the visual inspection of oral cancers during transoral robotic surgery (TORS) in real-time and without the need for exogenous contrast agents. TRFS enables identification of cancerous tissue by its distinct autofluorescence signature that is associated with the alteration of tissue structure and biochemical profile. A prototype TRFS instrument was integrated synergistically with the da Vinci Surgical robot and the combined system was validated in swine and human patients. Label-free and real-time assessment and visualization of tissue biochemical features during robotic surgery procedure, as demonstrated here, not only has the potential to improve the intraoperative decision making during TORS but also other robotic procedures without modification of conventional clinical protocols
Computer hardware and software for robotic control
The KSC has implemented an integrated system that coordinates state-of-the-art robotic subsystems. It is a sensor based real-time robotic control system performing operations beyond the capability of an off-the-shelf robot. The integrated system provides real-time closed loop adaptive path control of position and orientation of all six axes of a large robot; enables the implementation of a highly configurable, expandable testbed for sensor system development; and makes several smart distributed control subsystems (robot arm controller, process controller, graphics display, and vision tracking) appear as intelligent peripherals to a supervisory computer coordinating the overall systems
- …