29,382 research outputs found
Adaptive SPECT: personalizing medical imaging
We develop modern techniques for image quality evaluation and optimization of imaging systems, and use them to control adaptive SPECT systems. Our results should contribute to the development of more personalized and efficient medical imaging
Efficient optimization based on local shift-invariance for adaptive SPECT systems
Adaptive SPECT systems automatically change some of their settings to maximize the image quality for a given subject and purpose. This approach has a lot of potential, and could lead to drastic improvements in performance. In particular, it would be very useful in high resolution pinhole SPECT, where the low sensitivity requires higher radiation doses or longer imaging times compared to other systems. In order to have adaptation in real-time, we need a fast method for optimizing the adaptive settings according to a given figure of merit. This is still a big challenge. Based on previous work, we address in this paper the issue of fast evaluation of image quality and optimization, for a class of adaptive SPECT systems. We evaluate the image quality in a voxel of interest, reconstructed using post- filtered MLEM, with the contrast-to-noise ratio (CNR). The CNR is computed analytically, using an approximation based on the Fisher information matrix and assuming local shift-invariance on the Fisher information matrices per adaptation parameter. We maximize the CNR with a gradient based optimization approach. We then test this method in the optimization of the angular sampling of a single-head SPECT system which rotates around a phantom. In this case, the method proved to be very efficient, and at the same time showed good agreement with previous results in literature and with the outcome from reconstructions
Design and performance of a compact and stationary microSPECT system
Purpose: Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and multipinhole collimators working in large magnification mode. Spatial resolutions range from 0.58 to 0.76 mm while peak sensitivities vary from 0.06% to 0.4%. While pushing the limits of performance is of major importance, the authors believe that there is a need for smaller and less complex systems that bring along a reduced cost. While low footprint and low-cost systems can make microSPECT available to more researchers, the ease of operation and calibration and low maintenance cost are additional factors that can facilitate the use of microSPECT in molecular imaging. In this paper, the authors simulate the performance of a microSPECT imager that combines high space-bandwidth detectors and pinholes with truncated projection, resulting in a small and stationary system. Methods: A system optimization algorithm is used to determine the optimal SPECT systems, given our high resolutions detectors and a fixed field-of-view. These optimal system geometries are then used to simulate a Defrise disk phantom and a hot rod phantom. Finally, a MOBY mouse phantom, with realistic concentrations of Tc99m-tetrofosmin is simulated. Results: Results show that the authors can successfully reconstruct a Defrise disk phantom of 24 mm in diameter without any rotating system components or translation of the object. Reconstructed spatial resolution is approximately 800 mu m while the peak sensitivity is 0.23%. Finally, the simulation of the MOBY mouse phantom shows that the authors can accurately reconstruct mouse images. Conclusions: These results show that pinholes with truncated projections can be used in small magnification or minification mode to obtain a compact and stationary microSPECT system. The authors showed that they can reach state-of-the-art system performance and can successfully reconstruct images with realistic noise levels in a preclinical context. Such a system can be useful for dynamic SPECT imaging. 2013 American Association of Physicists in Medicine
Performance of the Gemini Planet Imager Non-Redundant Mask and spectroscopy of two close-separation binaries HR 2690 and HD 142527
The Gemini Planet Imager (GPI) contains a 10-hole non-redundant mask (NRM),
enabling interferometric resolution in complement to its coronagraphic
capabilities. The NRM operates both in spectroscopic (integral field
spectrograph, henceforth IFS) and polarimetric configurations. NRM observations
were taken between 2013 and 2016 to characterize its performance. Most
observations were taken in spectroscopic mode with the goal of obtaining
precise astrometry and spectroscopy of faint companions to bright stars. We
find a clear correlation between residual wavefront error measured by the AO
system and the contrast sensitivity by comparing phase errors in observations
of the same source, taken on different dates. We find a typical 5-
contrast sensitivity of at . We explore the
accuracy of spectral extraction of secondary components of binary systems by
recovering the signal from a simulated source injected into several datasets.
We outline data reduction procedures unique to GPI's IFS and describe a newly
public data pipeline used for the presented analyses. We demonstrate recovery
of astrometry and spectroscopy of two known companions to HR 2690 and HD
142527. NRM+polarimetry observations achieve differential visibility precision
of in the best case. We discuss its limitations on
Gemini-S/GPI for resolving inner regions of protoplanetary disks and prospects
for future upgrades. We summarize lessons learned in observing with NRM in
spectroscopic and polarimetric modes.Comment: Accepted to AJ, 22 pages, 14 figure
Spatially Resolved Stellar Populations of Eight GOODS-South AGN at z~1
We present a pilot study of the stellar populations of 8 AGN hosts at z~1 and
compare to (1) lower redshift samples and (2) a sample of nonactive galaxies of
similar redshift. We utilize K' images in the GOODS South field obtained with
the laser guide star adaptive optics (LGSAO) system at Keck Observatory. We
combine this K' data with B, V, i, and z imaging from the ACS on HST to give
multi-color photometry at a matched spatial resolution better than 100 mas in
all bands. The hosts harbor AGN as inferred from their high X-ray luminosities
(L_X > 10^42 ergs/s) or mid-IR colors. We find a correlation between the
presence of younger stellar populations and the strength of the AGN, as
measured with [OIII] line luminosity or X-ray (2-10 keV) luminosity. This
finding is consistent with similar studies at lower redshift. Of the three Type
II galaxies, two are disk galaxies and one is of irregular type, while in the
Type I sample there only one disk-like source and four sources with smooth,
elliptical/spheroidal morphologies. In addition, the mid-IR SEDs of the strong
Type II AGN indicate that they are excited to LIRG (Luminous InfraRed Galaxy)
status via galactic starbursting, while the strong Type I AGN are excited to
LIRG status via hot dust surrounding the central AGN. This supports the notion
that the obscured nature of Type II AGN at z~1 is connected with global
starbursting and that they may be extincted by kpc-scale dusty features that
are byproducts of this starbursting.Comment: 56 pages, 39 figures, accepted to A
- âŠ