83 research outputs found

    Nonlinear control of a seven degrees-of-freedom exoskeleton robot arm

    Get PDF
    Advances in the field of robotics have allowed increasingly integrating robotic devices for rehabilitation of physical disabilities. This research work is encompassed into the field of rehabilitation robotics; it presents the development of the robot ETS-MARSE, a seven degrees-of-freedom exoskeleton designed to be worn in the human arm. The developments include the study and implementation of a relatively novel nonlinear control approach, as well as different rehabilitation schemes. One of the characteristics of a rehabilitation robot is that it deals with a wide number of patients that have different biomechanical and physiological conditions. The implementation of the nonlinear control technique known as Virtual Decomposition Control addresses this issue with its internal parameters’ adaptation that presents a robust behavior to different characteristics of the robot users. Besides, this technique simplifies the complexity of high degree-of-freedom robots by its innovative sub-systems decomposition. All of above, while ensuring the system asymptotic stability and excellent trajectory tracking. Between the different rehabilitation schemes, we can mention: passive, active-assistive and active rehabilitation. The first one follows predefined trajectories and relies on the efficiency of the controller. The two other schemes require understanding the user’s intention of movement and take an action in order to guide, restrain, correct or follow it. For this purpose, we present an approach that utilizes a force sensor as the human-robot interface in order to transform, via an admittance function, the forces that the user exert to the robot end-effector (handle), and execute active-assisted or active rehabilitation. Finally among the main developments of this work, an approach is presented in which the need of a force sensor to perform some active rehabilitation tasks is removed. By means of a nonlinear observer, the interaction forces are estimated and the user’s intention of movement followed. Experimental results show the effectiveness of all the proposed approaches. All the tests involving humans were tested with healthy subjects. Trajectory tracking of the robot is executed in joint space; some trajectories are given in Cartesian space and transformed to joint space by means of the pseudoinverse of the Jacobian technique. However this option is limited; a mandatory next step to improve many functionalities of the robot is to solve its inverse kinematics. Between other progresses that are in development, is an approach to process electromyographic signals in order to obtain information from the robot’s users. First results on this methodology are presented. Teleoperation and haptic capabilities are also in the initial stage of development

    A Review of Lower Limb Exoskeletons

    Get PDF
    In general, exoskeletons are defined as wearable robotic mechanisms for providing mobility. In the last six decades, many research work have been achieved to enhance the performance of exoskeletons thus developing them to nearly commercialized products. In this paper, a review is made for the lower limb exoskeleton concerning history, classification, selection and development, also a discussion for the most important aspects of comparison between different designs is presented. Further, some concluding remarks are withdrawn which could be useful for future work. Keywords: Exoskeletons, Lower extremity exoskeleton, Wearable robot

    Editorial: Next Generation User-Adaptive Wearable Robots

    Get PDF
    Wearable robots, including powered exoskeletons and robotic prostheses, have created new possibilities for mobility augmentation and restoration among individuals with a variety of movement disorders, including spinal cord injury, stroke, amputation, and other neurological conditions (Esquenazi et al., 2017; Rodríguez-Fernández et al., 2021). Exoskeleton technology has progressed to create utility for unimpaired individuals by supporting load carriage, reducing joint loading or improving metabolic efficiency (Sawicki et al., 2020). Despite this progress, exoskeleton deployment in real-world, community environments remains limited. While there are multiple barriers to ubiquitous exoskeleton use, a key lynchpin is development of robust control systems that adapt to user intent, support the variety of mobility tasks that may be encountered, and account for variation in the user’s voluntary effort across such tasks

    A 3-DoF Robotic Platform for the Rehabilitation and Assessment of Reaction Time and Balance Skills of MS Patients

    Get PDF
    The central nervous system (CNS) exploits anticipatory (APAs) and compensatory (CPAs) postural adjustments to maintain the balance.The postural adjustments comprising stability of the center of mass (CoM) and the pressure distribution of the body influence each other if there is a lack of performance in either of them.Any predictable or sudden perturbation may pave the way for the divergence of CoM from equilibrium and in homogeneous pressure distribution of the body.Such a situation is often observed in daily livings of Multiple Sclerosis (MS) patients owing to their poor APAs and CPAs, and induces their falls.The way of minimizing risk of falls in neurological patients is utilizing perturbation-based rehabilitation, as it is efficient in the recovery of the balance disorder.In the light of the findings, we present the design, implementation, and experimental evaluation of a novel 3 DoF parallel manipulator to treat the balance disorder of MS.The robotic platform allows angular motion of the ankle based on its anthropomorphic freedom.The end-effector endowed with upper and lower platforms is designed to evaluate both the pressure distribution of each foot and the CoM of the body, respectively.Data gathered from the platforms are utilized to both evaluate performance of the patients and used in high-level control of the robotic platform to regulate the difficulty level of tasks.In this study, kinematic and dynamic analyses of the robot are derived and validated in the simulation environment. Low-level control of the prototype is also successfully implemented through PID controller.The capacity of each platform is evaluated with a set of experiments considering assessment of pressure distribution and CoM of the foot-like-objects on the end-effector. Experimental results indicate that such a system well-address the need for balance skill training and assessment through the APAs and CPAs.Comment: 12 figures, 29 pages, PLOS ON

    ROBOT-ASSISTED THERAPY: DESIGN, CONTROL AND OPTIMIZATION

    Full text link

    Robot-assisted rehabilitation architecture supported by a distributed data acquisition system

    Get PDF
    Rehabilitation robotics aims to facilitate the rehabilitation procedure for patients and physical therapists. This field has a relatively long history dating back to the 1990s; however, their implementation and the standardisation of their application in the medical field does not follow the same pace, mainly due to their complexity of reproduction and the need for their approval by the authorities. This paper aims to describe architecture that can be applied to industrial robots and promote their application in healthcare ecosystems. The control of the robotic arm is performed using the software called SmartHealth, offering a 2 Degree of Autonomy (DOA). Data are gathered through electromyography (EMG) and force sensors at a frequency of 45 Hz. It also proves the capabilities of such small robots in performing such medical procedures. Four exercises focused on shoulder rehabilitation (passive, restricted active-assisted, free active-assisted and Activities of Daily Living (ADL)) were carried out and confirmed the viability of the proposed architecture and the potential of small robots (i.e., the UR3) in rehabilitation procedure accomplishment. This robot can perform the majority of the default exercises in addition to ADLs but, nevertheless, their limits were also uncovered, mainly due to their limited Range of Motion (ROM) and cost.info:eu-repo/semantics/publishedVersio

    Reviewing high-level control techniques on robot-assisted upper-limb rehabilitation

    Get PDF
    This paper presents a comprehensive review of high-level control techniques for upper-limb robotic training. It aims to compare and discuss the potentials of these different control algorithms, and specify future research direction. Included studies mainly come from selected papers in four review articles. To make selected studies complete and comprehensive, especially some recently-developed upper-limb robotic devices, a search was further conducted in IEEE Xplore, Google Scholar, Scopus and Web of Science using keywords (‘upper limb*’ or ‘upper body*’) and (‘rehabilitation*’ or ‘treatment*’) and (‘robot*’ or ‘device*’ or ‘exoskeleton*’). The search is limited to English-language articles published between January 2013 and December 2017. Valuable references in related publications were also screened. Comparative analysis shows that high-level interaction control strategies can be implemented in a range of methods, mainly including impedance/admittance based strategies, adaptive control techniques, and physiological signal control. Even though the potentials of existing interactive control strategies have been demonstrated, it is hard to identify the one leading to maximum encouragement from human users. However, it is reasonable to suggest that future studies should combine different control strategies to be application specific, and deliver appropriate robotic assistance based on physical disability levels of human users
    • …
    corecore