713 research outputs found

    Medical image segmentation using edge-based active contours.

    Get PDF
    The main purpose of image segmentation using active contours is to extract the object of interest in images based on textural or boundary information. Active contour methods have been widely used in image segmentation applications due to their good boundary detection accuracy. In the context of medical image segmentation, weak edges and inhomogeneities remain important issues that may limit the accuracy of any segmentation method formulated using active contour models. This thesis develops new methods for segmentation of medical images based on the active contour models. Three different approaches are pursued: The first chapter proposes a novel external force that integrates gradient vector flow (GVF) field forces and balloon forces based on a weighting factor computed according to local image features. The proposed external force reduces noise sensitivity, improves performance over weak edges and allows initialization with a single manually selected point. The next chapter proposes a level set method that is based on the minimization of an objective energy functional whose energy terms are weighted according to their relative importance in detecting boundaries. This relative importance is computed based on local edge features collected from the adjacent region inside and outside of the evolving contour. The local edge features employed are the edge intensity and the degree of alignment between the images gradient vector flow field and the evolving contours normal. Finally, chapter 5 presents a framework that is capable of segmenting the cytoplasm of each individual cell and can address the problem of segmenting overlapping cervical cells using edge-based active contours. The main goal of our methodology is to provide significantly fully segmented cells with high accuracy segmentation results. All of the proposed methods are then evaluated for segmentation of various regions in real MRI and CT slices, X-ray images and cervical cell images. Evaluation results show that the proposed method leads to more accurate boundary detection results than other edge-based active contour methods (snake and level-set), particularly around weak edges

    Active contours with weighted external forces for medical image segmentation

    Get PDF
    Parametric active contours have been widely used for image segmentation. However, high noise levels and weak edges are the most acute issues that hinder their performance, particularly in medical images. In order to overcome these issues, we propose an external force that weights the gradient vector flow (GVF) field and balloon forces according to local image features. We also propose a mechanism to automatically terminate the contour's deformation. % process. %Our approach improves performance over noisy images and weak edges and allows snake's initialization using a limited number of manually selected points. Evaluation results on real MRI and CT slices show that the proposed approach attains higher segmentation accuracy than snakes using traditional external forces, while allowing initialization using a limited number of selected points

    Using a distance map and an active contour model to segment the carotid artery boundary from the lumen contour in proton density weighted magnetic resonance images

    Get PDF
    Segmentation methods have assumed an important role in image-based diagnosis of several cardiovascular diseases. Particularly, the segmentation of the boundary of the carotid artery is demanded in the detection and characterization of atherosclerosis and assessment of the disease progression. In this article, a fully automatic approach for the segmentation of the carotid artery boundary in Proton Density Weighted Magnetic Resonance Images is presented. The approach relies on the expansion of the lumen contour based on a distance map built using the gray-weighted distance relative to the center of the identified lumen region in the image under analysis. Then, a Snake model with a modified weighted external energy based on the combination of a balloon force along with a Gradient Vector Flow-based external energy is applied to the expanded contour towards the correct boundary of the carotid artery. The average values of the Dice coefficient, Polyline distance, mean contour distance and centroid distance found in the segmentation of 139 carotid arteries were 0.83 ± 0.11, 2.70 ± 1.69 pixels, 2.79 ± 1.89 pixels and 3.44 ± 2.82 pixels, respectively. The segmentation results of the proposed approach were also compared against the ones obtained by related approaches found in the literature, which confirmed the outstanding performance of the new approach. Additionally, the proposed weighted external energy for the Snake model was shown to be also robust to carotid arteries with large thickness and weak boundary image edges. (c) 202

    Active Contour Based Segmentation Techniques for Medical Image Analysis

    Get PDF
    Image processing is a technique which is used to derive information from the images. Segmentation is a section of image processing for the separation or segregation of information from the required target region of the image. There are different techniques used for segmentation of pixels of interest from the image. Active contour is one of the active models in segmentation techniques, which makes use of the energy constraints and forces in the image for separation of region of interest. Active contour defines a separate boundary or curvature for the regions of target object for segmentation. The contour depends on various constraints based on which they are classified into different types such as gradient vector flow, balloon and geometric models. Active contour models are used in various image processing applications specifically in medical image processing. In medical imaging, active contours are used in segmentation of regions from different medical images such as brain CT images, MRI images of different organs, cardiac images and different images of regions in the human body. Active contours can also be used in motion tracking and stereo tracking. Thus, the active contour segmentation is used for the separation of pixels of interest for different image processing

    On using an analogy to heat flow for shape extraction

    No full text
    We introduce a novel evolution-based segmentationalgorithm which uses the heat flow analogy togain practical advantage. The proposed algorithm consistsof two parts. In the first part, we represent a particular heatconduction problem in the image domain to roughly segmentthe region of interest. Then we use geometric heatflow to complete the segmentation, by smoothing extractedboundaries and removing noise inside the prior segmentedregion. The proposed algorithm is compared with activecontour models and is tested on synthetic and medicalimages. Experimental results indicate that our approachworks well in noisy conditions without pre-processing. Itcan detect multiple objects simultaneously. It is alsocomputationally more efficient and easier to control andimplement in comparison with active contour models

    Foetal echocardiographic segmentation

    Get PDF
    Congenital heart disease affects just under one percentage of all live births [1]. Those defects that manifest themselves as changes to the cardiac chamber volumes are the motivation for the research presented in this thesis. Blood volume measurements in vivo require delineation of the cardiac chambers and manual tracing of foetal cardiac chambers is very time consuming and operator dependent. This thesis presents a multi region based level set snake deformable model applied in both 2D and 3D which can automatically adapt to some extent towards ultrasound noise such as attenuation, speckle and partial occlusion artefacts. The algorithm presented is named Mumford Shah Sarti Collision Detection (MSSCD). The level set methods presented in this thesis have an optional shape prior term for constraining the segmentation by a template registered to the image in the presence of shadowing and heavy noise. When applied to real data in the absence of the template the MSSCD algorithm is initialised from seed primitives placed at the centre of each cardiac chamber. The voxel statistics inside the chamber is determined before evolution. The MSSCD stops at open boundaries between two chambers as the two approaching level set fronts meet. This has significance when determining volumes for all cardiac compartments since cardiac indices assume that each chamber is treated in isolation. Comparison of the segmentation results from the implemented snakes including a previous level set method in the foetal cardiac literature show that in both 2D and 3D on both real and synthetic data, the MSSCD formulation is better suited to these types of data. All the algorithms tested in this thesis are within 2mm error to manually traced segmentation of the foetal cardiac datasets. This corresponds to less than 10% of the length of a foetal heart. In addition to comparison with manual tracings all the amorphous deformable model segmentations in this thesis are validated using a physical phantom. The volume estimation of the phantom by the MSSCD segmentation is to within 13% of the physically determined volume
    corecore