    Rapid and Accurate C-V Measurements

    Get PDF
    We report a new technique for the rapid measurement of full capacitance-voltage (C-V) characteristic curves. The displacement current from a 100-MHz applied sine wave, which swings from accumulation to strong inversion, is digitized directly using an oscilloscope from the MOS capacitor under test. A C-V curve can be constructed directly from this data but is severely distorted due to nonideal behavior of real measurement systems. The key advance of this paper is to extract the system response function using the same measurement setup and a known MOS capacitor. The system response correction to the measured C-V curve of the unknown MOS capacitor can then be done by simple deconvolution. No deskewing and/or leakage current correction is necessary, making it a very simple and quick measurement. Excellent agreement between the new fast C-V method and C-V measured conventionally by an LCR meter is achieved. The total time required for measurement and analysis is approximately 2 s, which is limited by our equipment

    Instrumentation for observation of high frequency signals in the scanning electron microscope

    Get PDF
    SIGLELD:D48882/84 / BLDSC - British Library Document Supply CentreGBUnited Kingdo

    PMU-Based ROCOF Measurements: Uncertainty Limits and Metrological Significance in Power System Applications

    Full text link
    In modern power systems, the Rate-of-Change-of-Frequency (ROCOF) may be largely employed in Wide Area Monitoring, Protection and Control (WAMPAC) applications. However, a standard approach towards ROCOF measurements is still missing. In this paper, we investigate the feasibility of Phasor Measurement Units (PMUs) deployment in ROCOF-based applications, with a specific focus on Under-Frequency Load-Shedding (UFLS). For this analysis, we select three state-of-the-art window-based synchrophasor estimation algorithms and compare different signal models, ROCOF estimation techniques and window lengths in datasets inspired by real-world acquisitions. In this sense, we are able to carry out a sensitivity analysis of the behavior of a PMU-based UFLS control scheme. Based on the proposed results, PMUs prove to be accurate ROCOF meters, as long as the harmonic and inter-harmonic distortion within the measurement pass-bandwidth is scarce. In the presence of transient events, the synchrophasor model looses its appropriateness as the signal energy spreads over the entire spectrum and cannot be approximated as a sequence of narrow-band components. Finally, we validate the actual feasibility of PMU-based UFLS in a real-time simulated scenario where we compare two different ROCOF estimation techniques with a frequency-based control scheme and we show their impact on the successful grid restoration.Comment: Manuscript IM-18-20133R. Accepted for publication on IEEE Transactions on Instrumentation and Measurement (acceptance date: 9 March 2019

    An improved rocket-borne electric field meter for the middle atmosphere

    Get PDF
    Improvements in a rocketborne electric field meter designed to measure the atmosphere's electric field and conductivity in the middle atmosphere are described. The general background of the experiment is given as well as changes in the instrument and data processing schemes. Calibration and testing procedures are documented together with suggestions for future work

    Two improved methods for testing ADC parametric faults by digital input signals

    Get PDF
    In this paper, two improved methods are presented extending our previous work. The first one improves the results by adjusting the voltage levels of the input pulse wave stimulus. Compared with the sine wave input stimulus, the four-level pulse wave can detect even more faulty cases with the offset faults. The second one improves the results by calculating the similarity of the output spectra between the golden devices and the DUTs. Compared with the previous method [10], it is less sensitive to the jitter and the change of the rise/fall time of the input pulse wave stimulus. In these two methods, a number of golden devices are tested at first to obtain the fault-free range. At last, a signature result is obtained from both methods. It can filter out the faulty devices in a quick way before testing the specific values of the conventional dynamic and static parameters

    Frequency-modulated continuous-wave LiDAR compressive depth-mapping

    Get PDF
    We present an inexpensive architecture for converting a frequency-modulated continuous-wave LiDAR system into a compressive-sensing based depth-mapping camera. Instead of raster scanning to obtain depth-maps, compressive sensing is used to significantly reduce the number of measurements. Ideally, our approach requires two difference detectors. % but can operate with only one at the cost of doubling the number of measurments. Due to the large flux entering the detectors, the signal amplification from heterodyne detection, and the effects of background subtraction from compressive sensing, the system can obtain higher signal-to-noise ratios over detector-array based schemes while scanning a scene faster than is possible through raster-scanning. %Moreover, we show how a single total-variation minimization and two fast least-squares minimizations, instead of a single complex nonlinear minimization, can efficiently recover high-resolution depth-maps with minimal computational overhead. Moreover, by efficiently storing only 2m2m data points from m<nm<n measurements of an nn pixel scene, we can easily extract depths by solving only two linear equations with efficient convex-optimization methods

    Reducing MOSFET 1/f Noise and Power Consumption by "Switched Biasing"

    Get PDF
    Switched biasing is proposed as a technique for reducing the 1/f noise in MOSFET's. Conventional techniques, such as chopping or correlated double sampling, reduce the effect of 1/f noise in electronic circuits, whereas the switched biasing technique reduces the 1/f noise itself. Whereas noise reduction techniques generally lead to more power consumption, switched biasing can reduce the power consumption. It exploits an intriguing physical effect: cycling a MOS transistor from strong inversion to accumulation reduces its intrinsic 1/f noise. As the 1/f noise is reduced at its physical roots, high frequency circuits, in which 1/f noise is being upconverted, can also benefit. This is demonstrated by applying switched biasing in a 0.8 ¿m CMOS sawtooth oscillator. By periodically switching off the bias currents, during time intervals that they are not contributing to the circuit operation, a reduction of the 1/f noise induced phase noise by more than 8 dB is achieved, while the power consumption is also reduced by 30

    Non-contact Vital Signs Monitor

    Get PDF
    An apparatus for measuring simultaneous physiological parameters such as heart rate and respiration without physically connecting electrodes or other sensors to the body. A beam of frequency modulated continuous wave radio frequency energy is directed towards the body of a subject. The reflected signal contains phase information representing the movement of the surface of the body, from which respiration and heartbeat information can be obtained. The reflected phase modulated energy is received and demodulated by the apparatus using synchronous quadrature detection. The quadrature signals so obtained are then signal processed to obtain the heartbeat and respiratory information of interest.Georgia Tech Research Corporatio