19 research outputs found

    HARDWARE-ACCELERATED AUTOMATIC 3D NONRIGID IMAGE REGISTRATION

    Get PDF
    Software implementations of 3D nonrigid image registration, an essential tool in medical applications like radiotherapies and image-guided surgeries, run excessively slow on traditional computers. These algorithms can be accelerated using hardware methods by exploiting parallelism at different levels in the algorithm. We present here, an implementation of a free-form deformation-based algorithm on a field programmable gate array (FPGA) with a customized, parallel and pipelined architecture. We overcome the performance bottlenecks and gain speedups of up to 40x over traditional computers while achieving accuracies comparable to software implementations. In this work, we also present a method to optimize the deformation field using a gradient descent-based optimization scheme and solve the problem of mesh folding, commonly encountered during registration using free-form deformations, using a set of linear constraints. Finally, we present the use of novel dataflow modeling tools to automatically map registration algorithms to hardware like FPGAs while allowing for dynamic reconfiguration

    Efficient dense non-rigid registration using the free-form deformation framework

    Get PDF
    Medical image registration consists of finding spatial correspondences between two images or more. It is a powerful tool which is commonly used in various medical image processing tasks. Even though medical image registration has been an active topic of research for the last two decades, significant challenges in the field remain to be solved. This thesis addresses some of these challenges through extensions to the Free-Form Deformation (FFD) registration framework, which is one of the most widely used and well-established non-rigid registration algorithm. Medical image registration is a computationally expensive task because of the high degrees of freedom of the non-rigid transformations. In this work, the FFD algorithm has been re-factored to enable fast processing, while maintaining the accuracy of the results. In addition, parallel computing paradigms have been employed to provide near real-time image registration capabilities. Further modifications have been performed to improve the registration robustness to artifacts such as tissues non-uniformity. The plausibility of the generated deformation field has been improved through the use of bio-mechanical models based regularization. Additionally, diffeomorphic extensions to the algorithm were also developed. The work presented in this thesis has been extensively validated using brain magnetic resonance imaging of patients diagnosed with dementia or patients undergoing brain resection. It has also been applied to lung X-ray computed tomography and imaging of small animals. Alongside with this thesis an open-source package, NiftyReg, has been developed to release the presented work to the medical imaging community

    Computational Imaging Approach to Recovery of Target Coordinates Using Orbital Sensor Data

    Get PDF
    This dissertation addresses the components necessary for simulation of an image-based recovery of the position of a target using orbital image sensors. Each component is considered in detail, focusing on the effect that design choices and system parameters have on the accuracy of the position estimate. Changes in sensor resolution, varying amounts of blur, differences in image noise level, selection of algorithms used for each component, and lag introduced by excessive processing time all contribute to the accuracy of the result regarding recovery of target coordinates using orbital sensor data. Using physical targets and sensors in this scenario would be cost-prohibitive in the exploratory setting posed, therefore a simulated target path is generated using Bezier curves which approximate representative paths followed by the targets of interest. Orbital trajectories for the sensors are designed on an elliptical model representative of the motion of physical orbital sensors. Images from each sensor are simulated based on the position and orientation of the sensor, the position of the target, and the imaging parameters selected for the experiment (resolution, noise level, blur level, etc.). Post-processing of the simulated imagery seeks to reduce noise and blur and increase resolution. The only information available for calculating the target position by a fully implemented system are the sensor position and orientation vectors and the images from each sensor. From these data we develop a reliable method of recovering the target position and analyze the impact on near-realtime processing. We also discuss the influence of adjustments to system components on overall capabilities and address the potential system size, weight, and power requirements from realistic implementation approaches

    Aeronautical engineering: A cumulative index to a continuing bibliography

    Get PDF
    This bibliography is a cumulative index to the abstracts contained in NASA SP-7037(210) through NASA SP-7037(221) of Aeronautical Engineering: A Continuing Bibliography. NASA SP-7037 and its supplements have been compiled through the cooperative efforts of the American Institute of Aeronautics and Astronautics (AIAA) and the National Aeronautics and Space Administration (NASA). This cumulative index includes subject, personal author, corporate source, foreign technology, contract number, report number, and accession number indexes

    Research and technology operating plan: A summary Fiscal Year 1974

    Get PDF
    A compilation is presented of the summary portions of RTOPs used for management review and control of research. Citations and abstracts of RTOPs are included. A list is presented of RTOPs which have been changed, completed, or terminated since the last summary. Indexes presented include: subject, technical monitor, responsible NASA organization, and RTOP number

    Bibliography of Lewis Research Center technical publications announced in 1988

    Get PDF
    This bibliography contains abstracts of the technical reports that resulted from the scientific and engineering work performed and managed by the Lewis Research Center in 1988. Subject, author, and corporate source indexes are also included. All the publications were announced in the 1988 issues of STAR (Scientific and Technical Aerospace Reports) and/or IAA (International Aerospace Abstracts). Included are research reports, journal articles, conference presentations, patents and patent applications, and theses

    Geometrical Calibration and Filter Optimization for Cone-Beam Computed Tomography

    Get PDF
    This thesis will discuss the requirements of a software library for tomography and will derive a framework which can be used to realize various applications in cone-beam computed tomography (CBCT). The presented framework is self-contained and is realized using the MATLAB environment in combination with native low-level technologies (C/C++ and CUDA) to improve its computational performance, while providing accessibility and extendability through to use of a scripting language environment. On top of this framework, the realization of Katsevich鈥檚 algorithm on multicore hardware will be explained and the resulting implementation will be compared to the Feldkamp, Davis and Kress (FDK) algorithm. It will also be shown that this helical reconstruction method has the potential to reduce the measurement uncertainty. However, misalignment artifacts appear more severe in the helical reconstructions from real data than in the circular ones. Especially for helical CBCT (H-CBCT), this fact suggests that a precise calibration of the computed tomography (CT) system is inevitable. As a consequence, a self-calibration method will be designed that is able to estimate the misalignment parameters from the cone-beam projection data without the need of any additional measurements. The presented method employs a multi-resolution 2D-3D registration technique and a novel volume update scheme in combination with a stochastic reprojection strategy to achieve a reasonable runtime performance. The presented results will show that this method reaches sub-voxel accuracy and can compete with current state-of-the-art online- and offline-calibration approaches. Additionally, for the construction of filters in the area of limited-angle tomography a general scheme which uses the Approximate Inverse (AI) to compute an optimized set of 2D angle-dependent projection filters will be derived. Optimal sets of filters are then precomputed for two angular range setups and will be reused to perform various evaluations on multiple datasets with a filtered backprojection (FBP)-type method. This approach will be compared to the standard FDK algorithm and to the simultaneous iterative reconstruction technique (SIRT). The results of the study show that the introduced filter optimization produces results comparable to those of SIRT with respect to the reduction of reconstruction artifacts, whereby its runtime is comparable to that of the FDK algorithm
    corecore