5,141 research outputs found

    Communication system for a tooth-mounted RF sensor used for continuous monitoring of nutrient intake

    Get PDF
    In this Thesis, the communication system of a wearable device that monitors the user’s diet is studied. Based in a novel RF metamaterial-based mouth sensor, different decisions have to be made concerning the system’s technologies, such as the power source options for the device, the wireless technology used for communications and the method to obtain data from the sensor. These issues, along with other safety rules and regulations, are reviewed, as the first stage of development of the Food-Intake Monitoring projectOutgoin

    Freshwater Culture Of Salmonids In Recirculating Aquaculture Systems (RAS) With Emphasis On The Monitoring And Control Of Key Environmental Parameters

    Get PDF
    This report is intended as a briefing paper on Recirculating Aquaculture Systems with emphasis on the monitoring of water quality parameters relating to the freshwater culture of the Arctic charr Salvelinus alpinus

    A programmable microsystem using system-on-chip for real-time biotelemetry

    Get PDF
    A telemetry microsystem, including multiple sensors, integrated instrumentation and a wireless interface has been implemented. We have employed a methodology akin to that for System-on-Chip microelectronics to design an integrated circuit instrument containing several "intellectual property" blocks that will enable convenient reuse of modules in future projects. The present system was optimized for low-power and included mixed-signal sensor circuits, a programmable digital system, a feedback clock control loop and RF circuits integrated on a 5 mm × 5 mm silicon chip using a 0.6 μm, 3.3 V CMOS process. Undesirable signal coupling between circuit components has been investigated and current injection into sensitive instrumentation nodes was minimized by careful floor-planning. The chip, the sensors, a magnetic induction-based transmitter and two silver oxide cells were packaged into a 36 mm × 12 mm capsule format. A base station was built in order to retrieve the data from the microsystem in real-time. The base station was designed to be adaptive and timing tolerant since the microsystem design was simplified to reduce power consumption and size. The telemetry system was found to have a packet error rate of 10<sup>-</sup><sup>3</sup> using an asynchronous simplex link. Trials in animal carcasses were carried out to show that the transmitter was as effective as a conventional RF device whilst consuming less power

    Insights into the pathogenesis of nicotine addiction. Could a salivary biosensor be useful in Nicotine Replacement Therapy (NRT)?

    Get PDF
    Nicotine has gained the attention of the medical community due to its insidious addictive mechanisms which lead to chronic consumption. The multitude of compounds derived from tobacco smoke have local and systemic negative impacts, resulting in a large number of smoking-related pathologies. The present review offers insights into nicotine addiction physiopathology, as well as social and medical implications, with emphasis on its correlation with Advanced Glycation End Products (AGEs). Therapeutic strategies and new approaches to nicotine assessment and cessation treatment are discussed, noting that such strategies could take into account the possibility of slow and gradual nicotine release from a device attached to a prosthetic piece, based on salivary nicotine-concentration feedback. This approach could offer real-time and home-based self-therapy monitoring by the physician and the patient for follow-up and improve long-term cessation treatment success- Graphical abstract

    Wearable electrochemical biosensors in North America

    Get PDF
    Tremendous research and commercialization efforts around the world are focused on developing novel wearable electrochemical biosensors that can noninvasively and continuously screen for biochemical markers in body fluids for the prognosis, diagnosis and management of diseases, as well as the monitoring of fitness. Researchers in North America are leading the development of innovative wearable platforms that can comfortably comply to the human body and efficiently sample fluids such as sweat, interstitial fluids, tear and saliva for the electrochemical detection of biomarkers through various sensing approaches such as potentiometric ion selective electrodes and amperometric enzymatic sensors. We start this review with a historical timeline overviewing the major milestones in the development of wearable electrochemical sensors by North American institutions. We then describe how such research efforts have led to pioneering developments and are driving the advancement and commercialization of wearable electrochemical sensors: from minimally invasive continuous glucose monitors for chronic disease management to non-invasive sweat electrolyte sensors for dehydration monitoring in fitness applications. While many countries across the globe have contributed significantly to this rapidly emerging field, their contributions are beyond the scope of this review. Furthermore, we share our perspective on the promising future of wearable electrochemical sensors in applications spanning from remote and personalized healthcare to wellness

    Review—Lab-in-a-Mouth and Advanced Point-of-Care Sensing Systems: Detecting Bioinformation from the Oral Cavity and Saliva

    Get PDF
    Cavitas sensors and point-of-need sensors capable of providing physical and biochemical information from the oral cavity and saliva have attracted great attention because they offer remarkable advantages for noninvasive sensing systems. Herein, we introduce the basic anatomy and physiology of important body cavities to understand their characteristics as it is a pivotal foundation for the successful development of in-mouth devices. Next, the advanced development in lab-in-a-mouth sensors and point-of-need sensors for analyzing saliva are explained. In addition, we discuss the integrations of artificial intelligence and electronic technologies in smart sensing networks for healthcare systems. This review ends with a discussion of the challenges, future research trends, and opportunities in relevant disciplines. Mouthguard-based sensors and conventional salivary sensing devices will continue to be significant for the progress in the next-generation sensing technologies and smart healthcare systems.ope

    Distribution, movements, and habitat use of small striped bass (Morone saxatilis) across multiple spatial scales

    Get PDF
    Distribution, movements, and habitat use of small (<46 cm, juveniles and individuals of unknown maturity) striped bass (Morone saxatilis) were investigated with multiple techniques and at multiple spatial scales (surveys and tag-recapture in the estuary and ocean, and telemetry in the estuary) over multiple years to determine the frequency and duration of use of non-natal estuaries. These unique comparisons suggest, at least in New Jersey, that smaller individuals (<20 cm) may disperse from natal estuaries and arrive in non-natal estuaries early in life and take up residence for several years. During this period of estuarine residence, individuals spend all seasons primarily in the low salinity portions of the estuary. At larger sizes, they then leave these non-natal estuaries to begin coastal migrations with those individuals from nurseries in natal estuaries. These composite observations of frequency and duration of habitat use indicate that non-natal estuaries may provide important habitat for a portion of the striped bass population

    Introductory Chapter: Wearable Technologies for Healthcare Monitoring

    Get PDF
    corecore