1,147 research outputs found
Direct and Inverse Computational Methods for Electromagnetic Scattering in Biological Diagnostics
Scattering theory has had a major roll in twentieth century mathematical
physics. Mathematical modeling and algorithms of direct,- and inverse
electromagnetic scattering formulation due to biological tissues are
investigated. The algorithms are used for a model based illustration technique
within the microwave range. A number of methods is given to solve the inverse
electromagnetic scattering problem in which the nonlinear and ill-posed nature
of the problem are acknowledged.Comment: 61 pages, 5 figure
Determination of design and operation parameters for upper atmospheric research instrumentation to yield optimum resolution with deconvolution
The final report for work on the determination of design and operation parameters for upper atmospheric research instrumentation to yield optimum resolution with deconvolution is presented. Papers and theses prepared during the research report period are included. Among all the research results reported, note should be made of the specific investigation of the determination of design and operation parameters for upper atmospheric research instrumentation to yield optimum resolution with deconvolution. A methodology was developed to determine design and operation parameters for error minimization when deconvolution is included in data analysis. An error surface is plotted versus the signal-to-noise ratio (SNR) and all parameters of interest. Instrumental characteristics will determine a curve in this space. The SNR and parameter values which give the projection from the curve to the surface, corresponding to the smallest value for the error, are the optimum values. These values are constrained by the curve and so will not necessarily correspond to an absolute minimum in the error surface
Effects of errorless learning on the acquisition of velopharyngeal movement control
Session 1pSC - Speech Communication: Cross-Linguistic Studies of Speech Sound Learning of the Languages of Hong Kong (Poster Session)The implicit motor learning literature suggests a benefit for learning if errors are minimized during practice. This study investigated whether the same principle holds for learning velopharyngeal movement control. Normal speaking participants learned to produce hypernasal speech in either an errorless learning condition (in which the possibility for errors was limited) or an errorful learning condition (in which the possibility for errors was not limited). Nasality level of the participants’ speech was measured by nasometer and reflected by nasalance scores (in %). Errorless learners practiced producing hypernasal speech with a threshold nasalance score of 10% at the beginning, which gradually increased to a threshold of 50% at the end. The same set of threshold targets were presented to errorful learners but in a reversed order. Errors were defined by the proportion of speech with a nasalance score below the threshold. The results showed that, relative to errorful learners, errorless learners displayed fewer errors (50.7% vs. 17.7%) and a higher mean nasalance score (31.3% vs. 46.7%) during the acquisition phase. Furthermore, errorless learners outperformed errorful learners in both retention and novel transfer tests. Acknowledgment: Supported by The University of Hong Kong Strategic Research Theme for Sciences of Learning © 2012 Acoustical Society of Americapublished_or_final_versio
Métodos de reconstrucción en dominio temporal para tomografía por transmisión de ultrasonidos
Tesis inédita de la Universidad Complutense de Madrid, Facultad de Ciencias Físicas, Departamento de Física Atómica, Molecular y Nuclear, leída el 06-06-2017Breast cancer (BC) is the leading cause of cancer-related death for women in Europe, and the second one after lung cancer in the US [World Cancer Report, 2008]. Early detection is very important for the survival rate of BC, because the smaller the local extension of the neoplasia, the better the output of the surgical treatments employed. Besides, early detection increases the possibility of preserving the breast and decreases the probability of needing more invasive treatments [Secretaría de Salud, 2007, Alteri et al., 2011]. Mammography is currently the standard procedure employed for breast screening programs around the world. Nevertheless, its efficiency has been questioned lately because: (i) it generates many abnormal findings not related to cancer, (ii) it requires irradiating the patient and (iii) it has low specificity with dense breasts [Santen and Mansel, 2005]. Consequently, complementary techniques to mammography are being proposed to improve the detection and characterization of BC. Among these techniques, is the Ultrasound Computed Tomography (USCT), in reflection mode (which provides qualitative maps with the concentration of scatterers in the tissue), and transmission mode (which provides quantitative maps of the sound speed (SS) and the acoustic attenuation (AA) of the tissues). The images provided by the transmission modality have been proposed for BC detection as they can improve the detectability of malignancies in the breast [Mast, 2000, Duric et al., 2009]...El cáncer de mama (CM) es el cáncer más mortal entre las mujeres europeas, y el segundo más común en Estados Unidos [World Cancer Report, 2008]. La detección temprana es un factor que condiciona en gran medida la tasa de supervivencia a esta enfermedad, ya que a menor tamaño de la neoplasia detectada, mejores resultados pueden esperarse para los tratamientos quirúrgicos que se realicen. Además, la detección temprana aumenta la posibilidad de conservar la mama después de la cirugía y disminuye la necesidad de emplear otros tratamientos más invasivos[Secretaría de Salud, 2007, Alteri et al., 2011]. La mamografía es actualmente el procedimiento estándar que se emplea para el cribado del CM. Sin embargo, en los últimas años su eficiencia está siendo muy cuestionada por varios factores: (i) alta tasa de falsos positivos, (ii) requiere la irradiación del paciente y (iii) baja especificidad en mamas densas 2. Debido a lo anterior, para mejorar la detección y caracterización del CM se han propuesto varias técnicas complementarias. Entre ellas está la tomografía ultrasónica (TU), que es una técnica en desarrollo que presenta dos modalidades principales: la reflexión (proporciona mapas cualitativos de la concentración de dispersores en el tejido) y la transmisión (proporciona mapas cuantitativos de la velocidad y atenuación del sonido en el tejido). Los mapas del modo transmisión han sido propuestos como una eficiente alternativa, libre de radiación, para la detección del CM, ya que proporcionan alto contraste y especificidad [Mast, 2000, Duric et al., 2009]...Depto. de Estructura de la Materia, Física Térmica y ElectrónicaFac. de Ciencias FísicasTRUEunpu
- …