33 research outputs found

    Corticomuscular co-activation based hybrid brain-computer interface for motor recovery monitoring

    Get PDF
    The effect of corticomuscular coactivation based hybrid brain-computer interface (h-BCI) on post-stroke neurorehabilitation has not been explored yet. A major challenge in this area is to find an appropriate corticomuscular feature which can not only drive an h-BCI but also serve as a biomarker for motor recovery monitoring. Our previous study established the feasibility of a new method of measuring corticomuscular co-activation called correlation of band-limited power time-courses (CBPT) of EEG and EMG signals, outperforming the traditional EEG-EMG coherence in terms of accurately controlling a robotic hand exoskeleton device by the stroke patients. In this paper, we have evaluated the neurophysiological significance of CBPT for motor recovery monitoring by conducting a 5-week long longitudinal pilot trial on 4 chronic hemiparetic stroke patients. Results show that the CBPT variations correlated significantly (p-value< 0.05) with the dynamic changes in motor outcome measures during the therapy for all the patients. As the bandpower based biomarkers are popular in literature, a comparison with such biomarkers has also been made to cross-verify whether the changes in CBPT are indeed neurophysiological. Thus the study concludes that CBPT can serve as a biomarker for motor recovery monitoring while serving as a corticomuscular co-activation feature for h-BCI based neurorehabilitation. Despite an observed significant positive change between pre- and post-intervention motor outcomes, the question of the clinical effectiveness of CBPT is subject to further controlled trial on a larger cohort

    An EEG-EMG Correlation-based Brain-Computer Interface for Hand Orthosis Supported Neuro-Rehabilitation

    Get PDF
    Background Corticomuscular coupling has been investigated for long, to find out the underlying mechanisms behind cortical drives to produce different motor tasks. Although important in rehabilitation perspective, the use of corticomuscular coupling for driving brain-computer interface (BCI)-based neurorehabilitation is much ignored. This is primarily due to the fact that the EEG-EMG coherence popularly used to compute corticomuscular coupling, fails to produce sufficient accuracy in single-trial based prediction of motor tasks in a BCI system. New Method In this study, we have introduced a new corticomuscular feature extraction method based on the correlation between band-limited power time-courses (CBPT) associated with EEG and EMG. 16 healthy individuals and 8 hemiplegic patients participated in a BCI-based hand orthosis triggering task, to test the performance of the CBPT method. The healthy population was equally divided into two groups; one experimental group for CBPT-based BCI experiment and another control group for EEG-EMG coherence based BCI experiment. Results The classification accuracy of the CBPT-based BCI system was found to be 92.81±2.09% for the healthy experimental group and 84.53±4.58% for the patients’ group. Comparison with existing method The CBPT method significantly (p−value < 0.05) outperformed the conventional EEG-EMG coherence method in terms of classification accuracy. Conclusions The experimental results clearly indicate that the EEG-EMG CBPT is a better alternative as a corticomuscular feature to drive a BCI system. Additionally, it is also feasible to use the proposed method to design BCI-based robotic neurorehabilitation paradigms

    Brain-Computer Interface Robotics for Hand Rehabilitation After Stroke: A Systematic Review

    Get PDF
    Background Hand rehabilitation is core to helping stroke survivors regain activities of daily living. Recent studies have suggested that the use of electroencephalography-based brain-computer interfaces (BCI) can promote this process. Here, we report the first systematic examination of the literature on the use of BCI-robot systems for the rehabilitation of fine motor skills associated with hand movement and profile these systems from a technical and clinical perspective. Methods A search for January 2010–October 2019 articles using Ovid MEDLINE, Embase, PEDro, PsycINFO, IEEE Xplore and Cochrane Library databases was performed. The selection criteria included BCI-hand robotic systems for rehabilitation at different stages of development involving tests on healthy participants or people who have had a stroke. Data fields include those related to study design, participant characteristics, technical specifications of the system, and clinical outcome measures. Results 30 studies were identified as eligible for qualitative review and among these, 11 studies involved testing a BCI-hand robot on chronic and subacute stroke patients. Statistically significant improvements in motor assessment scores relative to controls were observed for three BCI-hand robot interventions. The degree of robot control for the majority of studies was limited to triggering the device to perform grasping or pinching movements using motor imagery. Most employed a combination of kinaesthetic and visual response via the robotic device and display screen, respectively, to match feedback to motor imagery. Conclusion 19 out of 30 studies on BCI-robotic systems for hand rehabilitation report systems at prototype or pre-clinical stages of development. We identified large heterogeneity in reporting and emphasise the need to develop a standard protocol for assessing technical and clinical outcomes so that the necessary evidence base on efficiency and efficacy can be developed

    The Use of Functional Electrical Stimulation on the Upper Limb and Interscapular Muscles of Patients with Stroke for the Improvement of Reaching Movements: A Feasibility Study

    Get PDF
    Introduction: Reaching movements in stroke patients are characterized by decreased amplitudes at the shoulder and elbow joints and greater displacements of the trunk, compared to healthy subjects. The importance of an appropriate and specific contraction of the interscapular and upper limb (UL) muscles is crucial to achieving proper reaching movements. Functional electrical stimulation (FES) is used to activate the paretic muscles using short-duration electrical pulses. Objective: To evaluate whether the application of FES in the UL and interscapular muscles of stroke patients with motor impairments of the UL modifies patients’ reaching patterns, measured using instrumental movement analysis systems. Design: A cross-sectional study was carried out. Setting: The VICON Motion System® was used to conduct motion analysis. Participants: Twenty-one patients with chronic stroke. Intervention: The Compex® electric stimulator was used to provide muscle stimulation during two conditions: a placebo condition and a FES condition. Main outcome measures: We analyzed the joint kinematics (trunk, shoulder, and elbow) from the starting position until the affected hand reached the glass. Results: Participants receiving FES carried out the movement with less trunk flexion, while shoulder flexion elbow extension was increased, compared to placebo conditions. Conclusion: The application of FES to the UL and interscapular muscles of stroke patients with motor impairment of the UL has improved reaching movements.This research has been supported by Spanish Ministry of Science project HYPER PROJECT (CONSOLIDER-INGENIO 2010) Hybrid Neuroprosthetic and Neurorobotic Devices for Functional Compensation and Rehabilitation of Motor Disorders. HYPER-CSD2009-00067

    EEG and ECoG features for Brain Computer Interface in Stroke Rehabilitation

    Get PDF
    The ability of non-invasive Brain-Computer Interface (BCI) to control an exoskeleton was used for motor rehabilitation in stroke patients or as an assistive device for the paralyzed. However, there is still a need to create a more reliable BCI that could be used to control several degrees of Freedom (DoFs) that could improve rehabilitation results. Decoding different movements from the same limb, high accuracy and reliability are some of the main difficulties when using conventional EEG-based BCIs and the challenges we tackled in this thesis. In this PhD thesis, we investigated that the classification of several functional hand reaching movements from the same limb using EEG is possible with acceptable accuracy. Moreover, we investigated how the recalibration could affect the classification results. For this reason, we tested the recalibration in each multi-class decoding for within session, recalibrated between-sessions, and between sessions. It was shown the great influence of recalibrating the generated classifier with data from the current session to improve stability and reliability of the decoding. Moreover, we used a multiclass extension of the Filter Bank Common Spatial Patterns (FBCSP) to improve the decoding accuracy based on features and compared it to our previous study using CSP. Sensorimotor-rhythm-based BCI systems have been used within the same frequency ranges as a way to influence brain plasticity or controlling external devices. However, neural oscillations have shown to synchronize activity according to motor and cognitive functions. For this reason, the existence of cross-frequency interactions produces oscillations with different frequencies in neural networks. In this PhD, we investigated for the first time the existence of cross-frequency coupling during rest and movement using ECoG in chronic stroke patients. We found that there is an exaggerated phase-amplitude coupling between the phase of alpha frequency and the amplitude of gamma frequency, which can be used as feature or target for neurofeedback interventions using BCIs. This coupling has been also reported in another neurological disorder affecting motor function (Parkinson and dystonia) but, to date, it has not been investigated in stroke patients. This finding might change the future design of assistive or therapeuthic BCI systems for motor restoration in stroke patients

    A brain-computer interface integrated with virtual reality and robotic exoskeletons for enhanced visual and kinaesthetic stimuli

    Get PDF
    Brain-computer interfaces (BCI) allow the direct control of robotic devices for neurorehabilitation and measure brain activity patterns following the user’s intent. In the past two decades, the use of non-invasive techniques such as electroencephalography and motor imagery in BCI has gained traction. However, many of the mechanisms that drive the proficiency of humans in eliciting discernible signals for BCI remains unestablished. The main objective of this thesis is to explore and assess what improvements can be made for an integrated BCI-robotic system for hand rehabilitation. Chapter 2 presents a systematic review of BCI-hand robot systems developed from 2010 to late 2019 in terms of their technical and clinical reports. Around 30 studies were identified as eligible for review and among these, 19 were still in their prototype or pre-clinical stages of development. A degree of inferiority was observed from these systems in providing the necessary visual and kinaesthetic stimuli during motor imagery BCI training. Chapter 3 discusses the theoretical background to arrive at a hypothesis that an enhanced visual and kinaesthetic stimulus, through a virtual reality (VR) game environment and a robotic hand exoskeleton, will improve motor imagery BCI performance in terms of online classification accuracy, class prediction probabilities, and electroencephalography signals. Chapters 4 and 5 focus on designing, developing, integrating, and testing a BCI-VR-robot prototype to address the research aims. Chapter 6 tests the hypothesis by performing a motor imagery BCI paradigm self-experiment with an enhanced visual and kinaesthetic stimulus against a control. A significant increase (p = 0.0422) in classification accuracies is reported among groups with enhanced visual stimulus through VR versus those without. Six out of eight sessions among the VR groups have a median of class probability values exceeding a pre-set threshold value of 0.6. Finally, the thesis concludes in Chapter 7 with a general discussion on how these findings could suggest the role of new and emerging technologies such as VR and robotics in advancing BCI-robotic systems and how the contributions of this work may help improve the usability and accessibility of such systems, not only in rehabilitation but also in skills learning and education

    Enhancement of Robot-Assisted Rehabilitation Outcomes of Post-Stroke Patients Using Movement-Related Cortical Potential

    Get PDF
    Post-stroke rehabilitation is essential for stroke survivors to help them regain independence and to improve their quality of life. Among various rehabilitation strategies, robot-assisted rehabilitation is an efficient method that is utilized more and more in clinical practice for motor recovery of post-stroke patients. However, excessive assistance from robotic devices during rehabilitation sessions can make patients perform motor training passively with minimal outcome. Towards the development of an efficient rehabilitation strategy, it is necessary to ensure the active participation of subjects during training sessions. This thesis uses the Electroencephalography (EEG) signal to extract the Movement-Related Cortical Potential (MRCP) pattern to be used as an indicator of the active engagement of stroke patients during rehabilitation training sessions. The MRCP pattern is also utilized in designing an adaptive rehabilitation training strategy that maximizes patients’ engagement. This project focuses on the hand motor recovery of post-stroke patients using the AMADEO rehabilitation device (Tyromotion GmbH, Austria). AMADEO is specifically developed for patients with fingers and hand motor deficits. The variations in brain activity are analyzed by extracting the MRCP pattern from the acquired EEG data during training sessions. Whereas, physical improvement in hand motor abilities is determined by two methods. One is clinical tests namely Fugl-Meyer Assessment (FMA) and Motor Assessment Scale (MAS) which include FMA-wrist, FMA-hand, MAS-hand movements, and MAS-advanced hand movements’ tests. The other method is the measurement of hand-kinematic parameters using the AMADEO assessment tool which contains hand strength measurements during flexion (force-flexion), and extension (force-extension), and Hand Range of Movement (HROM)

    Computational Intelligence in Electromyography Analysis

    Get PDF
    Electromyography (EMG) is a technique for evaluating and recording the electrical activity produced by skeletal muscles. EMG may be used clinically for the diagnosis of neuromuscular problems and for assessing biomechanical and motor control deficits and other functional disorders. Furthermore, it can be used as a control signal for interfacing with orthotic and/or prosthetic devices or other rehabilitation assists. This book presents an updated overview of signal processing applications and recent developments in EMG from a number of diverse aspects and various applications in clinical and experimental research. It will provide readers with a detailed introduction to EMG signal processing techniques and applications, while presenting several new results and explanation of existing algorithms. This book is organized into 18 chapters, covering the current theoretical and practical approaches of EMG research
    corecore