58 research outputs found

    Digital Background Self-Calibration Technique for Compensating Transition Offsets in Reference-less Flash ADCs

    Get PDF
    This Dissertation focusses on proving that background calibration using adaptive algorithms are low-cost, stable and effective methods for obtaining high accuracy in flash A/D converters. An integrated reference-less 3-bit flash ADC circuit has been successfully designed and taped out in UMC 180 nm CMOS technology in order to prove the efficiency of our proposed background calibration. References for ADC transitions have been virtually implemented built-in in the comparators dynamic-latch topology by a controlled mismatch added to each comparator input front-end. An external very simple DAC block (calibration bank) allows control the quantity of mismatch added in each comparator front-end and, therefore, compensate the offset of its effective transition with respect to the nominal value. In order to assist to the estimation of the offset of the prototype comparators, an auxiliary A/D converter with higher resolution and lower conversion speed than the flash ADC is used: a 6-bit capacitive-DAC SAR type. Special care in synchronization of analogue sampling instant in both ADCs has been taken into account. In this thesis, a criterion to identify the optimum parameters of the flash ADC design with adaptive background calibration has been set. With this criterion, the best choice for dynamic latch architecture, calibration bank resolution and flash ADC resolution are selected. The performance of the calibration algorithm have been tested, providing great programmability to the digital processor that implements the algorithm, allowing to choose the algorithm limits, accuracy and quantization errors in the arithmetic. Further, systematic controlled offset can be forced in the comparators of the flash ADC in order to have a more exhaustive test of calibration

    A power efficient delta-sigma ADC with series-bilinear switch capacitor voltage-controlled oscillator

    Get PDF
    In low-power VLSI design applications non-linearity and harmonics are a major dominant factor which affects the performance of the ADC. To avoid this, the new architecture of voltage-controlled oscillator (VCO) was required to solve the non-linearity issues and harmonic distortion. In this work, a 12-bit, 200MS/s low power delta-sigma analog to digital converter (ADC) VCO based quantizer was designed using switched capacitor technique. The proposed technique uses frequency to current conversion technique as a linearization method to reduce the non-linearity issue. Simulation result show that the proposed 12-bit delta-sigma ADC consumes the power of 2.68 mW and a total area of 0.09 mm² in 90 nm CMOS process

    A 16-b 10Msample/s Split-Interleaved Analog to Digital Converter

    Get PDF
    This work describes the integrated circuit design of a 16-bit, 10Msample/sec, combination ‘split’ interleaved analog to digital converter. Time interleaving of analog to digital converters has been used successfully for many years as a technique to achieve faster speeds using multiple identical converters. However, efforts to achieve higher resolutions with this technique have been difficult due to the precise matching required of the converter channels. The most troublesome errors in these types of converters are gain, offset and timing differences between channels. The ‘split ADC’ is a new concept that allows the use of a deterministic, digital, self calibrating algorithm. In this approach, an ADC is split into two paths, producing two output codes from the same input sample. The difference of these two codes is used as the calibration signal for an LMS error estimation algorithm that drives the difference error to zero. The ADC is calibrated when the codes are equal and the output is taken as the average of the two codes. The ‘split’ ADC concept and interleaved architecture are combined in this IC design to form the core of a high speed, high resolution, and self-calibrating ADC system. The dual outputs are used to drive a digital calibration engine to correct for the channel mismatch errors. This system has the speed benefits of interleaving while maintaining high resolution. The hardware for the algorithm as well as the ADC can be implemented in a standard 0.25um CMOS process, resulting in a relatively inexpensive solution. This work is supported by grants from Analog Devices Incorporated (ADI) and the National Science Foundation (NSF)

    Energy Efficient Pipeline ADCs Using Ring Amplifiers

    Full text link
    Pipeline ADCs require accurate amplification. Traditionally, an operational transconductance amplifier (OTA) configured as a switched-capacitor (SC) amplifier performs such amplification. However, traditional OTAs limit the power efficiency of ADCs since they require high quiescent current for slewing and bandwidth. In addition, it is difficult to design low-voltage OTAs in modern, scaled CMOS. The ring amplifier is an energy efficient and high output swing alternative to an OTA for SC circuits which is basically a three-stage inverter amplifier stabilized in a feedback configuration. However, the conventional ring amplifier requires external biases, which makes the ring amplifier less practical when we consider process, supply voltage, and temperature (PVT) variation. In this dissertation, three types of innovative ring amplifiers are presented and verified with state-of-the-art energy efficient pipeline ADCs. These new ring amplifiers overcome the limitations of the conventional ring amplifier and further improve energy efficiency. The first topic of this dissertation is a self-biased ring amplifier that makes the ring amplifier more practical and power efficient, while maintaining the benefits of efficient slew-based charging and an almost rail-to-rail output swing. In addition, the ring amplifiers are also used as comparators in the 1.5b sub-ADCs by utilizing the unique characteristics of the ring amplifier. This removes the need for dedicated comparators in sub-ADCs, thus further reducing the power consumption of the ADC. The prototype 10.5b 100 MS/s comparator-less pipeline ADC with the self-biased ring amplifiers has measured SNDR, SNR and SFDR of 56.6 dB (9.11b), 57.5 dB and 64.7 dB, respectively, and consumes 2.46 mW, which results in Walden Figure-of-Merit (FoM) of 46.1 fJ/ conversion∙step. The second topic is a fully-differential ring amplifier, which solves the problems of single-ended ring amplifiers while maintaining the benefits of the single-ended ring amplifiers. This differential ring-amplifier is applied in a 13b 50 MS/s SAR-assisted pipeline ADC. Furthermore, an improved capacitive DAC switching method for the first stage SAR reduces the DAC linearity errors and switching energy. The prototype ADC achieves measured SNDR, SNR and SFDR of 70.9 dB (11.5b), 71.3 dB and 84.6 dB, respectively, and consumes 1 mW. This measured performance is equivalent to Walden and Schreier FoMs of 6.9 fJ/conversion∙step and 174.9 dB, respectively. Finally, a four-stage fully-differential ring amplifier improves the small-signal gain to over 90 dB without compromising speed. In addition, a new auto-zero noise filtering method reduces noise without consuming additional power. This is more area efficient than the conventional auto-zero noise folding reduction technique. A systematic mismatch free SAR CDAC layout method is also presented. The prototype 15b 100 MS/s calibration-free SAR-assisted pipeline ADC using the four-stage ring amplifier achieves 73.2 dB SNDR (11.9b) and 90.4 dB SFDR with a 1.1 V supply. It consumes 2.3 mW resulting in Schreier FoM of 176.6 dB.PHDElectrical EngineeringUniversity of Michigan, Horace H. Rackham School of Graduate Studieshttps://deepblue.lib.umich.edu/bitstream/2027.42/138759/1/yonglim_1.pd

    Analysis and design of low-power data converters

    Get PDF
    In a large number of applications the signal processing is done exploiting both analog and digital signal processing techniques. In the past digital and analog circuits were made on separate chip in order to limit the interference and other side effects, but the actual trend is to realize the whole elaboration chain on a single System on Chip (SoC). This choice is driven by different reasons such as the reduction of power consumption, less silicon area occupation on the chip and also reliability and repeatability. Commonly a large area in a SoC is occupied by digital circuits, then, usually a CMOS short-channel technological processes optimized to realize digital circuits is chosen to maximize the performance of the Digital Signal Proccessor (DSP). Opposite, the short-channel technology nodes do not represent the best choice for analog circuits. But in a large number of applications, the signals which are treated have analog nature (microphone, speaker, antenna, accelerometers, biopotential, etc.), then the input and output interfaces of the processing chip are analog/mixed-signal conversion circuits. Therefore in a single integrated circuit (IC) both digital and analog circuits can be found. This gives advantages in term of total size, cost and power consumption of the SoC. The specific characteristics of CMOS short-channel processes such as: • Low breakdown voltage (BV) gives a power supply limit (about 1.2 V). • High threshold voltage VTH (compared with the available voltage supply) fixed in order to limit the leakage power consumption in digital applications (of the order of 0.35 / 0.4V), puts a limit on the voltage dynamic, and creates many problems with the stacked topologies. • Threshold voltage dependent on the channel length VTH = f(L) (short channel effects). • Low value of the output resistance of the MOS (r0) and gm limited by speed saturation, both causes contribute to achieving a low intrinsic gain gmr0 = 20 to 26dB. • Mismatch which brings offset effects on analog circuits. make the design of high performance analog circuits very difficult. Realizing lowpower circuits is fundamental in different contexts, and for different reasons: lowering the power dissipation gives the capability to reduce the batteries size in mobile devices (laptops, smartphones, cameras, measuring instruments, etc.), increase the life of remote sensing devices, satellites, space probes, also allows the reduction of the size and weight of the heat sink. The reduction of power dissipation allows the realization of implantable biomedical devices that do not damage biological tissue. For this reason, the analysis and design of low power and high precision analog circuits is important in order to obtain high performance in technological processes that are not optimized for such applications. Different ways can be taken to reduce the effect of the problems related to the technology: • Circuital level: a circuit-level intervention is possible to solve a specific problem of the circuit (i.e. Techniques for bandwidth expansion, increase the gain, power reduction, etc.). • Digital calibration: it is the highest level to intervene, and generally going to correct the non-ideal structure through a digital processing, these aims are based on models of specific errors of the structure. • Definition of new paradigms. This work has focused the attention on a very useful mixed-signal circuit: the pipeline ADC. The pipeline ADCs are widely used for their energy efficiency in high-precision applications where a resolution of about 10-16 bits and sampling rates above hundreds of Mega-samples per second (telecommunication, radar, etc.) are needed. An introduction on the theory of pipeline ADC, its state of the art and the principal non-idealities that affect the energy efficiency and the accuracy of this kind of data converters are reported in Chapter 1. Special consideration is put on low-voltage low-power ADCs. In particular, for ADCs implemented in deep submicron technology nodes side effects called short channel effects exist opposed to older technology nodes where undesired effects are not present. An overview of the short channel effects and their consequences on design, and also power consuption reduction techniques, with particular emphasis on the specific techniques adopted in pipelined ADC are reported in Chapter 2. Moreover, another way may be undertaken to increase the accuracy and the efficiency of an ADC, this way is the digital calibration. In Chapter 3 an overview on digital calibration techniques, and furthermore a new calibration technique based on Volterra kernels are reported. In some specific applications, such as software defined radios or micropower sensor, some circuits should be reconfigurable to be suitable for different radio standard or process signals with different charateristics. One of this building blocks is the ADC that should be able to reconfigure the resolution and conversion frequency. A reconfigurable voltage-scalable ADC pipeline capable to adapt its voltage supply starting from the required conversion frequency was developed, and the results are reported in Chapter 4. In Chapter 5, a pipeline ADC based on a novel paradigm for the feedback loop and its theory is described

    Design of a Cost-Efficient Reconfigurable Pipeline ADC

    Get PDF
    Power budget is very critical in the design of battery-powered implantable biomedical instruments. High speed, high resolution and low power usually cannot be achieved at the same time. Therefore, a tradeoff must be made to compromise every aspect of those features. As the main component of the bioinstrument, high conversion rate, high resolution ADC consumes most of the power. Fortunately, based on the operation modes of the bioinstrument, a reconfigurable ADC can be used to solve this problem. The reconfigurable ADC will operate at 10-bit 40 MSPS for the diagnosis mode and at 8-bit 2.5 MSPS for the monitor mode. The ADC will be completely turned off if no active signal comes from sensors or if an off command is received from the antenna. By turning off the sample hold stage and the first two stages of the pipeline ADC, a significant power saving is achieved. However, the reconfigurable ADC suffers from two drawbacks. First, the leakage signals through the extra off-state switches in the third stage degrade the performance of the data converter. This situation tends to be even worse for high speed and high-resolution applications. An interference elimination technique has been proposed in this work to solve this problem. Simulation results show a significant attenuation of the spurious tones. Moreover, the transistors in the OTA tend to operate in weak inversion region due to the scaling of the bias current. The transistor in subthreshold is very slow due to the small transit frequency. In order to get a better tradeoff between the transconductance efficiency and the transit frequency, reconfigurable OTAs and scalable bias technique are devised to adjust the operating point from weak inversion to moderate inversion. The figure of merit of the reconfigurable ADC is comparable to the previously published conventional pipeline ADCs. For the 10-bit, 40 MSPS mode, the ADC attains a 56.9 dB SNDR for 35.4 mW power consumption. For the 8-bit 2.5 MSPS mode, the ADC attains a 49.2 dB SNDR for 7.9 mW power consumption. The area for the core layout is 1.9 mm2 for a 0.35 micrometer process

    A Low-Power, Reconfigurable, Pipelined ADC with Automatic Adaptation for Implantable Bioimpedance Applications

    Get PDF
    Biomedical monitoring systems that observe various physiological parameters or electrochemical reactions typically cannot expect signals with fixed amplitude or frequency as signal properties can vary greatly even among similar biosignals. Furthermore, advancements in biomedical research have resulted in more elaborate biosignal monitoring schemes which allow the continuous acquisition of important patient information. Conventional ADCs with a fixed resolution and sampling rate are not able to adapt to signals with a wide range of variation. As a result, reconfigurable analog-to-digital converters (ADC) have become increasingly more attractive for implantable biosensor systems. These converters are able to change their operable resolution, sampling rate, or both in order convert changing signals with increased power efficiency. Traditionally, biomedical sensing applications were limited to low frequencies. Therefore, much of the research on ADCs for biomedical applications focused on minimizing power consumption with smaller bias currents resulting in low sampling rates. However, recently bioimpedance monitoring has become more popular because of its healthcare possibilities. Bioimpedance monitoring involves injecting an AC current into a biosample and measuring the corresponding voltage drop. The frequency of the injected current greatly affects the amplitude and phase of the voltage drop as biological tissue is comprised of resistive and capacitive elements. For this reason, a full spectrum of measurements from 100 Hz to 10-100 MHz is required to gain a full understanding of the impedance. For this type of implantable biomedical application, the typical low power, low sampling rate analog-to-digital converter is insufficient. A different optimization of power and performance must be achieved. Since SAR ADC power consumption scales heavily with sampling rate, the converters that sample fast enough to be attractive for bioimpedance monitoring do not have a figure-of-merit that is comparable to the slower converters. Therefore, an auto-adapting, reconfigurable pipelined analog-to-digital converter is proposed. The converter can operate with either 8 or 10 bits of resolution and with a sampling rate of 0.1 or 20 MS/s. Additionally, the resolution and sampling rate are automatically determined by the converter itself based on the input signal. This way, power efficiency is increased for input signals of varying frequency and amplitude
    • …
    corecore