549 research outputs found

    Robust sliding mode‐based extremum‐seeking controller for reaction systems via uncertainty estimation approach

    Get PDF
    "This paper deals with the design of a robust sliding mode‐based extremum‐seeking controller aimed at the online optimization of a class of uncertain reaction systems. The design methodology is based on an input–output linearizing method with variable‐structure feedback, such that the closed‐loop system converges to a neighborhood of the optimal set point with sliding mode motion. In contrast with previous extremum‐seeking control algorithms, the control scheme includes a dynamic modelling‐error estimator to compensate for unknown terms related with model uncertainties and unmeasured disturbances. The proposed online optimization scheme does not make use of a dither signal or a gradient‐based optimization algorithm. Practical stabilizability for the closed‐loop system around to the unknown optimal set point is analyzed. Numerical experiments for two nonlinear processes illustrate the effectiveness of the proposed robust control scheme.

    A survey on fractional order control techniques for unmanned aerial and ground vehicles

    Get PDF
    In recent years, numerous applications of science and engineering for modeling and control of unmanned aerial vehicles (UAVs) and unmanned ground vehicles (UGVs) systems based on fractional calculus have been realized. The extra fractional order derivative terms allow to optimizing the performance of the systems. The review presented in this paper focuses on the control problems of the UAVs and UGVs that have been addressed by the fractional order techniques over the last decade

    Multi-Parametric Extremum Seeking-based Auto-Tuning for Robust Input-Output Linearization Control

    Full text link
    We study in this paper the problem of iterative feedback gains tuning for a class of nonlinear systems. We consider Input-Output linearizable nonlinear systems with additive uncertainties. We first design a nominal Input-Output linearization-based controller that ensures global uniform boundedness of the output tracking error dynamics. Then, we complement the robust controller with a model-free multi-parametric extremum seeking (MES) control to iteratively auto-tune the feedback gains. We analyze the stability of the whole controller, i.e. robust nonlinear controller plus model-free learning algorithm. We use numerical tests to demonstrate the performance of this method on a mechatronics example.Comment: To appear at the IEEE CDC 201

    A review of optimization approaches for controlling water-cooled central cooling systems

    Get PDF
    Buildings consume a large amount of energy across all sectors of society, and a large proportion of building energy is used by HVAC systems to provide a comfortable and healthy indoor environment. In medium and large-size buildings, the central cooling system accounts for a major share of the energy consumption of the HVAC system. Improving the cooling system efficiency has gained much attention as the reduction of cooling system energy use can effectively contribute to environmental sustainability. The control and operation play an important role in central cooling system energy efficiency under dynamic working conditions. It has been proven that optimization of the control of the central cooling system can notably reduce the energy consumption of the system and mitigate greenhouse gas emissions. In recent years, numerous studies focus on this topic to improve the performance of optimal control in different aspects (e.g., energy efficiency, stability, robustness, and computation efficiency). This paper provides an up-to-date overview of the research and development of optimization approaches for controlling water-cooled central cooling systems, helping readers to understand the new significant trends and achievements in this area. The optimization approaches have been classified as system-model-based and data-based. In this paper, the optimization methodology is introduced first by summarizing the key decision variables, objective function, constraints, and optimization algorithms. The principle and performance of various optimization approaches are then summarized and compared according to their classification. Finally, the challenges and development trends for optimal control of water-cooled central cooling systems are discussed

    Reliability Enhancing Control Algorithms for Two-Stage Grid-Tied Inverters

    Get PDF
    In the photovoltaic (PV) generation system, two types of grid-tied inverter systems are usually deployed: the single-stage grid-tied inverter system and the two-stage grid-tied inverter system. In the single-stage grid-tied inverter system, the input of the inverter is directly connected to the PV arrays, while an additional dc-dc stage is inserted between the PV arrays and the dc-ac inverter in the two-stage design. The additional dc-dc stage could provide a stable dc-link voltage to the inverter, which also enables new design possibilities, including the multi-MPPT operation and solar-plus-storage application. Thus, the two-stage grid-tied inverter has been widely used in the PV generation system.As the core component of the PV generation system, the reliability of the grid-tied inverter determines the overall robustness of the system. The two-stage grid-tied inverter system includes three parts: the dc-dc stage, dc-link capacitor, and dc-ac inverter. Thus, the reliability of the two-stage grid-tied inverter relies on the reliability of each part. The dc-dc stage is used to provide a stable dc-link voltage to the inverter. However, when the inverter stage provides constant power to the grid, the load of the dc-dc stage becomes the constant power load (CPL), which will deteriorate the stability of the dc-dc stage. The dc-link capacitor is used to attenuate the voltage ripple on the dc-link and balance the transient power mismatch between the dc-dc stage and the dc-ac stage. However, during the operation of the inverter system, the degradation of the capacitor will reduce the converter reliability, and even result in system failure. The inverter stage is connected to the grid through the output filter, and the LCL type filter has been commonly used due to its superior performance. The resonance of the LCL filter must be properly damped to enhance the inverter stability. However, the grid-side impedance will lead to the resonant frequency drifting of the LCL filter, which will worsen the stability margin of the inverter. Thus, the control design of the two-stage grid-tied inverter system must consider those reliability challenges. In this work, three control algorithms are proposed to solve the reliability challenges. For the dc-dc stage, an uncertainty and disturbance estimator (UDE) based robust voltage control scheme is proposed. The proposed voltage control scheme can actively estimate and compensate for the disturbance of the dc-dc stage. Both the disturbance rejection performance and the stability margin of the dc-dc stage, especially under the CPL, could be enhanced. For the dc-link capacitor, a high-frequency (HF) signal injection based capacitance estimation scheme is proposed. The proposed estimation scheme can monitor the actual dc-link capacitance in real-time. For the inverter stage, an adaptive extremum seeking control (AESC) based LCL filter resonant frequency estimation scheme is proposed. The AESC-based estimation scheme can estimate the resonant frequency of the LCL filter online. All the proposed reliability enhancing control algorithms could enhance the reliability of the two-stage grid-tied inverter system. Detailed theoretical analysis, simulation studies, and comprehensive experimental studies have been performed to validate the effectiveness

    Reliability Enhancing Control Algorithms for Two-Stage Grid-Tied Inverters

    Get PDF
    In the photovoltaic (PV) generation system, two types of grid-tied inverter systems are usually deployed: the single-stage grid-tied inverter system and the two-stage grid-tied inverter system. In the single-stage grid-tied inverter system, the input of the inverter is directly connected to the PV arrays, while an additional dc-dc stage is inserted between the PV arrays and the dc-ac inverter in the two-stage design. The additional dc-dc stage could provide a stable dc-link voltage to the inverter, which also enables new design possibilities, including the multi-MPPT operation and solar-plus-storage application. Thus, the two-stage grid-tied inverter has been widely used in the PV generation system.As the core component of the PV generation system, the reliability of the grid-tied inverter determines the overall robustness of the system. The two-stage grid-tied inverter system includes three parts: the dc-dc stage, dc-link capacitor, and dc-ac inverter. Thus, the reliability of the two-stage grid-tied inverter relies on the reliability of each part. The dc-dc stage is used to provide a stable dc-link voltage to the inverter. However, when the inverter stage provides constant power to the grid, the load of the dc-dc stage becomes the constant power load (CPL), which will deteriorate the stability of the dc-dc stage. The dc-link capacitor is used to attenuate the voltage ripple on the dc-link and balance the transient power mismatch between the dc-dc stage and the dc-ac stage. However, during the operation of the inverter system, the degradation of the capacitor will reduce the converter reliability, and even result in system failure. The inverter stage is connected to the grid through the output filter, and the LCL type filter has been commonly used due to its superior performance. The resonance of the LCL filter must be properly damped to enhance the inverter stability. However, the grid-side impedance will lead to the resonant frequency drifting of the LCL filter, which will worsen the stability margin of the inverter. Thus, the control design of the two-stage grid-tied inverter system must consider those reliability challenges. In this work, three control algorithms are proposed to solve the reliability challenges. For the dc-dc stage, an uncertainty and disturbance estimator (UDE) based robust voltage control scheme is proposed. The proposed voltage control scheme can actively estimate and compensate for the disturbance of the dc-dc stage. Both the disturbance rejection performance and the stability margin of the dc-dc stage, especially under the CPL, could be enhanced. For the dc-link capacitor, a high-frequency (HF) signal injection based capacitance estimation scheme is proposed. The proposed estimation scheme can monitor the actual dc-link capacitance in real-time. For the inverter stage, an adaptive extremum seeking control (AESC) based LCL filter resonant frequency estimation scheme is proposed. The AESC-based estimation scheme can estimate the resonant frequency of the LCL filter online. All the proposed reliability enhancing control algorithms could enhance the reliability of the two-stage grid-tied inverter system. Detailed theoretical analysis, simulation studies, and comprehensive experimental studies have been performed to validate the effectiveness
    • 

    corecore