145 research outputs found
Extraction of Blood Vessels Geometric Shape Features with Catheter Localization and Geodesic Distance Transform for Right Coronary Artery Detection.
X-ray angiography is considered the standard imaging sensory system for diagnosing coronary artery diseases. For automated, accurate diagnosis of such diseases, coronary vessels’ detection from the captured low quality and noisy angiography images is challenging. It is essential to detect the main branch of the coronary artery, to resolve such limitations along with the problems due to the sudden changes in the lumen diameter, and the abrupt changes in local artery direction. Accordingly, this paper solved these limitations by proposing a computer-aided detection system for the right coronary artery (RCA) extraction, where geometric shape features with catheter localization and geodesic distance transform in the angiography images through two parts. In part 1, the captured image was initially preprocessed for contrast enhancement using singular value decomposition-based contrast adjustment, followed by generating the vesselness map using Jerman filter, and for further segmentation the K-means was introduced. Afterward, in part 2, the geometric shape features of the RCA, as well as the skeleton gradient transform, and the start/end points were determined to extract the main blood vessel of the RCA. The analysis of the skeletonize image was performed using Geodesic distance transform to examine all branches starting from the predetermined start point and cover the branching till the predefined end points. A ranking matrix, and the inverse of skeletonization were finally carried out to get the actual main branch. The performance of the proposed system was then evaluated using different evaluation metrics on the angiography images...
Towards a Digital Twin of Coronary Stenting: A Suitable and Validated Image-Based Approach for Mimicking Patient-Specific Coronary Arteries
Considering the field of application involving stent deployment simulations, the exploitation of a digital twin of coronary stenting that can reliably mimic the patient-specific clinical reality could lead to improvements in individual treatments. A starting step to pursue this goal is the development of simple, but at the same time, robust and effective computational methods to obtain a good compromise between the accuracy of the description of physical phenomena and computational costs. Specifically, this work proposes an approach for the development of a patient-specific artery model to be used in stenting simulations. The finite element model was generated through a 3D reconstruction based on the clinical imaging (coronary Optical Coherence Tomography (OCT) and angiography) acquired on the pre-treatment patient. From a mechanical point of view, the coronary wall was described with a suitable phenomenological model, which is consistent with more complex constitutive approaches and accounts for the in vivo pressurization and axial pre-stretch. The effectiveness of this artery modeling method was tested by reproducing in silico the stenting procedures of two clinical cases and comparing the computational results with the in vivo lumen area of the stented vessel
Medical image registration by neural networks: a regression-based registration approach
This thesis focuses on the development and evaluation of a registration-by-regression approach for the 3D/2D registration of coronary Computed Tomography Angiography (CTA) and X-ray angiography. This regression-based method relates image features of 2D projection images to the transformation parameters of the 3D image by a nonlinear regression. It treats registration as a regression problem, as an alternative for the traditional iterative approach that often comes with high computational costs and limited capture range.
First we presented a survey of the methods with a regression-based registration approach for medical applications, as well as a summary of their main characteristics (Chapter 2). Second, we studied the registration methodology, addressing the input features and the choice of regression model (Chapter 3 and Chapter 4). For that purpose, we evaluated different options using simulated X-ray images generated from coronary artery tree models derived from 3D CTA scans. We also compared the registration-by-regression results with a method based on iterative optimization. Different image features of 2D projections and seven regression techniques were considered. The regression approach for simulated X-rays was shown to be slightly less accurate, but much more robust than the method based on an iterative optimization approach. Neural Networks obtained accurate results and showed to be robust to large initial misalignment.
Third, we evaluated the registration-by-regression method using clinical data, integrating the 3D preoperative CTA of the coronary arteries with intraoperative 2D X-ray angiography images (Chapter 5). For the evaluation of the image registration, a gold standard registration was established using an exhaustive search followed by a multi-observer visual scoring procedure. The influence of preprocessing options for the simulated images and the real X-rays was studied. Several image features were also compared. The coronary registration–by-regression results were not satisfactory, resembling manual initialization accuracy.
Therefore, the proposed method for this concrete problem and in its current configuration is not sufficiently accurate to be used in the clinical practice. The framework developed enables us to better understand the dependency of the proposed method on the differences between simulated and real images. The main difficulty lies in the substantial differences in appearance between the images used for training (simulated X-rays from 3D coronary models) and the actual images obtained during the intervention (real X-ray angiography). We suggest alternative solutions and recommend to evaluate the registration-by-regression approach in other applications where training data is available that has similar appearance to the eventual test data
Computer Vision Techniques for Transcatheter Intervention
Minimally invasive transcatheter technologies have demonstrated substantial promise for the diagnosis and treatment of cardiovascular diseases. For example, TAVI is an alternative to AVR for the treatment of severe aortic stenosis and TAFA is widely used for the treatment and cure of atrial fibrillation. In addition, catheter-based IVUS and OCT imaging of coronary arteries provides important information about the coronary lumen, wall and plaque characteristics. Qualitative and quantitative analysis of these cross-sectional image data will be beneficial for the evaluation and treatment of coronary artery diseases such as atherosclerosis. In all the phases (preoperative, intraoperative, and postoperative) during the transcatheter intervention procedure, computer vision techniques (e.g., image segmentation, motion tracking) have been largely applied in the field to accomplish tasks like annulus measurement, valve selection, catheter placement control, and vessel centerline extraction. This provides beneficial guidance for the clinicians in surgical planning, disease diagnosis, and treatment assessment. In this paper, we present a systematical review on these state-of-the-art methods.We aim to give a comprehensive overview for researchers in the area of computer vision on the subject of transcatheter intervention. Research in medical computing is multi-disciplinary due to its nature, and hence it is important to understand the application domain, clinical background, and imaging modality so that methods and quantitative measurements derived from analyzing the imaging data are appropriate and meaningful. We thus provide an overview on background information of transcatheter intervention procedures, as well as a review of the computer vision techniques and methodologies applied in this area
Automatic Spatiotemporal Analysis of Cardiac Image Series
RÉSUMÉ
Ă€ ce jour, les maladies cardiovasculaires demeurent au premier rang des principales causes de
décès en Amérique du Nord. Chez l’adulte et au sein de populations de plus en plus jeunes,
la soi-disant épidémie d’obésité entraînée par certaines habitudes de vie tels que la mauvaise
alimentation, le manque d’exercice et le tabagisme est lourde de conséquences pour les personnes
affectées, mais aussi sur le système de santé. La principale cause de morbidité et de
mortalité chez ces patients est l’athérosclérose, une accumulation de plaque à l’intérieur des
vaisseaux sanguins à hautes pressions telles que les artères coronaires. Les lésions athérosclérotiques
peuvent entraîner l’ischémie en bloquant la circulation sanguine et/ou en provoquant
une thrombose. Cela mène souvent à de graves conséquences telles qu’un infarctus. Outre les
problèmes liés à la sténose, les parois artérielles des régions criblées de plaque augmentent la
rigidité des parois vasculaires, ce qui peut aggraver la condition du patient. Dans la population
pédiatrique, la pathologie cardiovasculaire acquise la plus fréquente est la maladie de
Kawasaki. Il s’agit d’une vasculite aigüe pouvant affecter l’intégrité structurale des parois des
artères coronaires et mener à la formation d’anévrismes. Dans certains cas, ceux-ci entravent
l’hémodynamie artérielle en engendrant une perfusion myocardique insuffisante et en activant
la formation de thromboses.
Le diagnostic de ces deux maladies coronariennes sont traditionnellement effectués à l’aide
d’angiographies par fluoroscopie. Pendant ces examens paracliniques, plusieurs centaines de
projections radiographiques sont acquises en séries suite à l’infusion artérielle d’un agent de
contraste. Ces images révèlent la lumière des vaisseaux sanguins et la présence de lésions
potentiellement pathologiques, s’il y a lieu. Parce que les séries acquises contiennent de l’information
très dynamique en termes de mouvement du patient volontaire et involontaire (ex.
battements cardiaques, respiration et déplacement d’organes), le clinicien base généralement
son interprétation sur une seule image angiographique où des mesures géométriques sont effectuées
manuellement ou semi-automatiquement par un technicien en radiologie. Bien que
l’angiographie par fluoroscopie soit fréquemment utilisé partout dans le monde et souvent
considéré comme l’outil de diagnostic “gold-standard” pour de nombreuses maladies vasculaires,
la nature bidimensionnelle de cette modalité d’imagerie est malheureusement très
limitante en termes de spécification géométrique des différentes régions pathologiques. En effet,
la structure tridimensionnelle des sténoses et des anévrismes ne peut pas être pleinement
appréciée en 2D car les caractéristiques observées varient selon la configuration angulaire de
l’imageur. De plus, la présence de lésions affectant les artères coronaires peut ne pas refléter
la véritable santé du myocarde, car des mécanismes compensatoires naturels (ex. vaisseaux----------ABSTRACT
Cardiovascular disease continues to be the leading cause of death in North America. In adult
and, alarmingly, ever younger populations, the so-called obesity epidemic largely driven by
lifestyle factors that include poor diet, lack of exercise and smoking, incurs enormous stresses
on the healthcare system. The primary cause of serious morbidity and mortality for these
patients is atherosclerosis, the build up of plaque inside high pressure vessels like the coronary
arteries. These lesions can lead to ischemic disease and may progress to precarious blood
flow blockage or thrombosis, often with infarction or other severe consequences. Besides
the stenosis-related outcomes, the arterial walls of plaque-ridden regions manifest increased
stiffness, which may exacerbate negative patient prognosis. In pediatric populations, the
most prevalent acquired cardiovascular pathology is Kawasaki disease. This acute vasculitis
may affect the structural integrity of coronary artery walls and progress to aneurysmal lesions.
These can hinder the blood flow’s hemodynamics, leading to inadequate downstream
perfusion, and may activate thrombus formation which may lead to precarious prognosis.
Diagnosing these two prominent coronary artery diseases is traditionally performed using
fluoroscopic angiography. Several hundred serial x-ray projections are acquired during selective
arterial infusion of a radiodense contrast agent, which reveals the vessels’ luminal
area and possible pathological lesions. The acquired series contain highly dynamic information
on voluntary and involuntary patient movement: respiration, organ displacement and
heartbeat, for example. Current clinical analysis is largely limited to a single angiographic
image where geometrical measures will be performed manually or semi-automatically by a
radiological technician. Although widely used around the world and generally considered
the gold-standard diagnosis tool for many vascular diseases, the two-dimensional nature of
this imaging modality is limiting in terms of specifying the geometry of various pathological
regions. Indeed, the 3D structures of stenotic or aneurysmal lesions may not be fully appreciated
in 2D because their observable features are dependent on the angular configuration of
the imaging gantry. Furthermore, the presence of lesions in the coronary arteries may not
reflect the true health of the myocardium, as natural compensatory mechanisms may obviate
the need for further intervention. In light of this, cardiac magnetic resonance perfusion
imaging is increasingly gaining attention and clinical implementation, as it offers a direct
assessment of myocardial tissue viability following infarction or suspected coronary artery
disease. This type of modality is plagued, however, by motion similar to that present in fluoroscopic
imaging. This issue predisposes clinicians to laborious manual intervention in order
to align anatomical structures in sequential perfusion frames, thus hindering automation o
Recommended from our members
Blood Vessel Segmentation and shape analysis for quantification of Coronary Artery Stenosis in CT Angiography
This thesis presents an automated framework for quantitative vascular shape analysis of the coronary arteries, which constitutes an important and fundamental component of an automated image-based diagnostic system. Firstly, an automated vessel segmentation algorithm is developed to extract the coronary arteries based on the framework of active contours. Both global and local intensity statistics are utilised in the energy functional calculation, which allows for dealing with non-uniform brightness conditions, while evolving the contour towards to the desired boundaries without being trapped in local minima. To suppress kissing vessel artifacts, a slice-by-slice correction scheme, based on multiple regions competition, is proposed to identify and track the kissing vessels throughout the transaxial images of the CTA data. Based on the resulting segmentation, we then present a dedicated algorithm to estimate the geometric parameters of the extracted arteries, with focus on vessel bifurcations. In particular, the centreline and associated reference surface of the coronary arteries, in the vicinity of arterial bifurcations, are determined by registering an elliptical cross sectional tube to the desired constituent branch. The registration problem is solved by a hybrid optimisation method, combining local greedy search and dynamic programming, which ensures the global optimality of the solution and permits the incorporation of any hard constraints posed to the tube model within a natural and direct framework. In contrast with conventional volume domain methods, this technique works directly on the mesh domain, thus alleviating the need for image upsampling. The performance of the proposed framework, in terms of efficiency and accuracy, is demonstrated on both synthetic and clinical image data. Experimental results have shown that our techniques are capable of extracting the major branches of the coronary arteries and estimating the related geometric parameters (i.e., the centreline and the reference surface) with a high degree of agreement to those obtained through manual delineation. Particularly, all of the major branches of coronary arteries are successfully detected by the proposed technique, with a voxel-wise error at 0.73 voxels to the manually delineated ground truth data. Through the application of the slice-by-slice correction scheme, the false positive metric, for those coronary segments affected by kissing vessel artifacts, reduces from 294% to 22.5%. In terms of the capability of the presented framework in defining the location of centrelines across vessel bifurcations, the mean square errors (MSE) of the resulting centreline, with respect to the ground truth data, is reduced by an average of 62.3%, when compared with initial estimation obtained using a topological thinning based algorithm
Automatic Spatiotemporal Analysis of Cardiac Image Series
RÉSUMÉ
Ă€ ce jour, les maladies cardiovasculaires demeurent au premier rang des principales causes de
décès en Amérique du Nord. Chez l’adulte et au sein de populations de plus en plus jeunes,
la soi-disant épidémie d’obésité entraînée par certaines habitudes de vie tels que la mauvaise
alimentation, le manque d’exercice et le tabagisme est lourde de conséquences pour les personnes
affectées, mais aussi sur le système de santé. La principale cause de morbidité et de
mortalité chez ces patients est l’athérosclérose, une accumulation de plaque à l’intérieur des
vaisseaux sanguins à hautes pressions telles que les artères coronaires. Les lésions athérosclérotiques
peuvent entraîner l’ischémie en bloquant la circulation sanguine et/ou en provoquant
une thrombose. Cela mène souvent à de graves conséquences telles qu’un infarctus. Outre les
problèmes liés à la sténose, les parois artérielles des régions criblées de plaque augmentent la
rigidité des parois vasculaires, ce qui peut aggraver la condition du patient. Dans la population
pédiatrique, la pathologie cardiovasculaire acquise la plus fréquente est la maladie de
Kawasaki. Il s’agit d’une vasculite aigüe pouvant affecter l’intégrité structurale des parois des
artères coronaires et mener à la formation d’anévrismes. Dans certains cas, ceux-ci entravent
l’hémodynamie artérielle en engendrant une perfusion myocardique insuffisante et en activant
la formation de thromboses.
Le diagnostic de ces deux maladies coronariennes sont traditionnellement effectués à l’aide
d’angiographies par fluoroscopie. Pendant ces examens paracliniques, plusieurs centaines de
projections radiographiques sont acquises en séries suite à l’infusion artérielle d’un agent de
contraste. Ces images révèlent la lumière des vaisseaux sanguins et la présence de lésions
potentiellement pathologiques, s’il y a lieu. Parce que les séries acquises contiennent de l’information
très dynamique en termes de mouvement du patient volontaire et involontaire (ex.
battements cardiaques, respiration et déplacement d’organes), le clinicien base généralement
son interprétation sur une seule image angiographique où des mesures géométriques sont effectuées
manuellement ou semi-automatiquement par un technicien en radiologie. Bien que
l’angiographie par fluoroscopie soit fréquemment utilisé partout dans le monde et souvent
considéré comme l’outil de diagnostic “gold-standard” pour de nombreuses maladies vasculaires,
la nature bidimensionnelle de cette modalité d’imagerie est malheureusement très
limitante en termes de spécification géométrique des différentes régions pathologiques. En effet,
la structure tridimensionnelle des sténoses et des anévrismes ne peut pas être pleinement
appréciée en 2D car les caractéristiques observées varient selon la configuration angulaire de
l’imageur. De plus, la présence de lésions affectant les artères coronaires peut ne pas refléter
la véritable santé du myocarde, car des mécanismes compensatoires naturels (ex. vaisseaux----------ABSTRACT
Cardiovascular disease continues to be the leading cause of death in North America. In adult
and, alarmingly, ever younger populations, the so-called obesity epidemic largely driven by
lifestyle factors that include poor diet, lack of exercise and smoking, incurs enormous stresses
on the healthcare system. The primary cause of serious morbidity and mortality for these
patients is atherosclerosis, the build up of plaque inside high pressure vessels like the coronary
arteries. These lesions can lead to ischemic disease and may progress to precarious blood
flow blockage or thrombosis, often with infarction or other severe consequences. Besides
the stenosis-related outcomes, the arterial walls of plaque-ridden regions manifest increased
stiffness, which may exacerbate negative patient prognosis. In pediatric populations, the
most prevalent acquired cardiovascular pathology is Kawasaki disease. This acute vasculitis
may affect the structural integrity of coronary artery walls and progress to aneurysmal lesions.
These can hinder the blood flow’s hemodynamics, leading to inadequate downstream
perfusion, and may activate thrombus formation which may lead to precarious prognosis.
Diagnosing these two prominent coronary artery diseases is traditionally performed using
fluoroscopic angiography. Several hundred serial x-ray projections are acquired during selective
arterial infusion of a radiodense contrast agent, which reveals the vessels’ luminal
area and possible pathological lesions. The acquired series contain highly dynamic information
on voluntary and involuntary patient movement: respiration, organ displacement and
heartbeat, for example. Current clinical analysis is largely limited to a single angiographic
image where geometrical measures will be performed manually or semi-automatically by a
radiological technician. Although widely used around the world and generally considered
the gold-standard diagnosis tool for many vascular diseases, the two-dimensional nature of
this imaging modality is limiting in terms of specifying the geometry of various pathological
regions. Indeed, the 3D structures of stenotic or aneurysmal lesions may not be fully appreciated
in 2D because their observable features are dependent on the angular configuration of
the imaging gantry. Furthermore, the presence of lesions in the coronary arteries may not
reflect the true health of the myocardium, as natural compensatory mechanisms may obviate
the need for further intervention. In light of this, cardiac magnetic resonance perfusion
imaging is increasingly gaining attention and clinical implementation, as it offers a direct
assessment of myocardial tissue viability following infarction or suspected coronary artery
disease. This type of modality is plagued, however, by motion similar to that present in fluoroscopic
imaging. This issue predisposes clinicians to laborious manual intervention in order
to align anatomical structures in sequential perfusion frames, thus hindering automation o
- …