456 research outputs found
Noncontact Vital Signs Detection
Human health condition can be accessed by measurement of vital signs, i.e., respiratory rate (RR), heart rate (HR), blood oxygen level, temperature and blood pressure. Due to drawbacks of contact sensors in measurement, non-contact sensors such as imaging photoplethysmogram (IPPG) and Doppler radar system have been proposed for cardiorespiratory rates detection by researchers.The UWB pulse Doppler radars provide high resolution range-time-frequency information. It is bestowed with advantages of low transmitted power, through-wall capabilities, and high resolution in localization. However, the poor signal to noise ratio (SNR) makes it challenging for UWB radar systems to accurately detect the heartbeat of a subject. To solve the problem, phased-methods have been proposed to extract the phase variations in the reflected pulses modulated by human tiny thorax motions. Advance signal processing method, i.e., state space method, can not only be used to enhance SNR of human vital signs detection, but also enable the micro-Doppler trajectories extraction of walking subject from UWB radar data.Stepped Frequency Continuous Wave (SFCW) radar is an alternative technique useful to remotely monitor human subject activities. Compared with UWB pulse radar, it relieves the stress on requirement of high sampling rate analog-to-digital converter (ADC) and possesses higher signal-to-noise-ratio (SNR) in vital signs detection. However, conventional SFCW radar suffers from long data acquisition time to step over many frequencies. To solve this problem, multi-channel SFCW radar has been proposed to step through different frequency bandwidths simultaneously. Compressed sensing (CS) can further reduce the data acquisition time by randomly stepping through 20% of the original frequency steps.In this work, SFCW system is implemented with low cost, off-the-shelf surface mount components to make the radar sensors portable. Experimental results collected from both pulse and SFCW radar systems have been validated with commercial contact sensors and satisfactory results are shown
Measurement Matrix Design for Compressive Sensing Based MIMO Radar
In colocated multiple-input multiple-output (MIMO) radar using compressive
sensing (CS), a receive node compresses its received signal via a linear
transformation, referred to as measurement matrix. The samples are subsequently
forwarded to a fusion center, where an L1-optimization problem is formulated
and solved for target information. CS-based MIMO radar exploits the target
sparsity in the angle-Doppler-range space and thus achieves the high
localization performance of traditional MIMO radar but with many fewer
measurements. The measurement matrix is vital for CS recovery performance. This
paper considers the design of measurement matrices that achieve an optimality
criterion that depends on the coherence of the sensing matrix (CSM) and/or
signal-to-interference ratio (SIR). The first approach minimizes a performance
penalty that is a linear combination of CSM and the inverse SIR. The second one
imposes a structure on the measurement matrix and determines the parameters
involved so that the SIR is enhanced. Depending on the transmit waveforms, the
second approach can significantly improve SIR, while maintaining CSM comparable
to that of the Gaussian random measurement matrix (GRMM). Simulations indicate
that the proposed measurement matrices can improve detection accuracy as
compared to a GRMM
Cognitive Sub-Nyquist Hardware Prototype of a Collocated MIMO Radar
We present the design and hardware implementation of a radar prototype that
demonstrates the principle of a sub-Nyquist collocated multiple-input
multiple-output (MIMO) radar. The setup allows sampling in both spatial and
spectral domains at rates much lower than dictated by the Nyquist sampling
theorem. Our prototype realizes an X-band MIMO radar that can be configured to
have a maximum of 8 transmit and 10 receive antenna elements. We use frequency
division multiplexing (FDM) to achieve the orthogonality of MIMO waveforms and
apply the Xampling framework for signal recovery. The prototype also implements
a cognitive transmission scheme where each transmit waveform is restricted to
those pre-determined subbands of the full signal bandwidth that the receiver
samples and processes. Real-time experiments show reasonable recovery
performance while operating as a 4x5 thinned random array wherein the combined
spatial and spectral sampling factor reduction is 87.5% of that of a filled
8x10 array.Comment: 5 pages, Compressed Sensing Theory and its Applications to Radar,
Sonar and Remote Sensing (CoSeRa) 201
- …