264 research outputs found

    Models and Analysis of Vocal Emissions for Biomedical Applications

    Get PDF
    The MAVEBA Workshop proceedings, held on a biannual basis, collect the scientific papers presented both as oral and poster contributions, during the conference. The main subjects are: development of theoretical and mechanical models as an aid to the study of main phonatory dysfunctions, as well as the biomedical engineering methods for the analysis of voice signals and images, as a support to clinical diagnosis and classification of vocal pathologies

    Models and Analysis of Vocal Emissions for Biomedical Applications

    Get PDF
    The MAVEBA Workshop proceedings, held on a biannual basis, collect the scientific papers presented both as oral and poster contributions, during the conference. The main subjects are: development of theoretical and mechanical models as an aid to the study of main phonatory dysfunctions, as well as the biomedical engineering methods for the analysis of voice signals and images, as a support to clinical diagnosis and classification of vocal pathologies

    Advancements and Breakthroughs in Ultrasound Imaging

    Get PDF
    Ultrasonic imaging is a powerful diagnostic tool available to medical practitioners, engineers and researchers today. Due to the relative safety, and the non-invasive nature, ultrasonic imaging has become one of the most rapidly advancing technologies. These rapid advances are directly related to the parallel advancements in electronics, computing, and transducer technology together with sophisticated signal processing techniques. This book focuses on state of the art developments in ultrasonic imaging applications and underlying technologies presented by leading practitioners and researchers from many parts of the world

    Measurement and analysis of breath sounds

    Get PDF
    Existing breath sound measurement systems and possible new methods have been critically investigated. The frequency response of each part of the measurement system has been studied. Emphasis has been placed on frequency response of acoustic sensors; especially, a method to study a diaphragm type air-coupler in contact use has been proposed. Two new methods of breath sounds measurement have been studied: laser Doppler vibrometer and mobile phones. It has been shown that these two methods can find applications in breath sounds measurement, however there are some restrictions. A reliable automatic wheeze detection algorithm based on auditory modelling has been developed. That is the human’s auditory system is modelled as a bank of band pass filters, in which the bandwidths are frequency dependent. Wheezes are treated as signals additive to normal breath sounds (masker). Thus wheeze is detectable when it is above the masking threshold. This new algorithm has been validated using simulated and real data. It is superior to previous algorithms, being more reliable to detect wheezes and less prone to mistakes. Simulation of cardiorespiratory sounds and wheeze audibility tests have been developed. Simulated breath sounds can be used as a training tool, as well as an evaluation method. These simulations have shown that, under certain circumstance, there are wheezes but they are inaudible. It is postulated that this could also happen in real measurements. It has been shown that simulated sounds with predefined characteristics can be used as an objective method to evaluate automatic algorithms. Finally, the efficiency and necessity of heart sounds reduction procedures has been investigated. Based on wavelet decomposition and selective synthesis, heart sounds can be reduced with a cost of unnatural breath sounds. Heart sound reduction is shown not to be necessary if a time-frequency representation is used, as heart sounds have a fixed pattern in the time-frequency plane

    Automatic Pain Assessment by Learning from Multiple Biopotentials

    Get PDF
    Kivun täsmällinen arviointi on tärkeää kivunhallinnassa, erityisesti sairaan- hoitoa vaativille ipupotilaille. Kipu on subjektiivista, sillä se ei ole pelkästään aistituntemus, vaan siihen saattaa liittyä myös tunnekokemuksia. Tällöin itsearviointiin perustuvat kipuasteikot ovat tärkein työkalu, niin auan kun potilas pystyy kokemuksensa arvioimaan. Arviointi on kuitenkin haasteellista potilailla, jotka eivät itse pysty kertomaan kivustaan. Kliinisessä hoito- työssä kipua pyritään objektiivisesti arvioimaan esimerkiksi havainnoimalla fysiologisia muuttujia kuten sykettä ja käyttäytymistä esimerkiksi potilaan kasvonilmeiden perusteella. Tutkimuksen päätavoitteena on automatisoida arviointiprosessi hyödyntämällä koneoppimismenetelmiä yhdessä biosignaalien prosessointnin kanssa. Tavoitteen saavuttamiseksi mitattiin autonomista keskushermoston toimintaa kuvastavia biopotentiaaleja: sydänsähkökäyrää, galvaanista ihoreaktiota ja kasvolihasliikkeitä mittaavaa lihassähkökäyrää. Mittaukset tehtiin terveillä vapaaehtoisilla, joille aiheutettiin kokeellista kipuärsykettä. Järestelmän kehittämiseen tarvittavaa tietokantaa varten rakennettiin biopotentiaaleja keräävä Internet of Things -pohjainen tallennusjärjestelmä. Koostetun tietokannan avulla kehitettiin biosignaaleille prosessointimenetelmä jatku- vaan kivun arviointiin. Signaaleista eroteltiin piirteitä sekuntitasoon mukautetuilla aikaikkunoilla. Piirteet visualisoitiin ja tarkasteltiin eri luokittelijoilla kivun ja kiputason tunnistamiseksi. Parhailla luokittelumenetelmillä saavutettiin kivuntunnistukseen 90% herkkyyskyky (sensitivity) ja 84% erottelukyky (specificity) ja kivun voimakkuuden arviointiin 62,5% tarkkuus (accuracy). Tulokset vahvistavat kyseisen käsittelytavan käyttökelpoisuuden erityis- esti tunnistettaessa kipua yksittäisessä arviointi-ikkunassa. Tutkimus vahvistaa biopotentiaalien avulla kehitettävän automatisoidun kivun arvioinnin toteutettavuuden kokeellisella kivulla, rohkaisten etenemään todellisen kivun tutkimiseen samoilla menetelmillä. Menetelmää kehitettäessä suoritettiin lisäksi vertailua ja yhteenvetoa automaattiseen kivuntunnistukseen kehitettyjen eri tutkimusten välisistä samankaltaisuuksista ja eroista. Tarkastelussa löytyi signaalien eroavaisuuksien lisäksi tutkimusmuotojen aiheuttamaa eroa arviointitavoitteisiin, mikä hankaloitti tutkimusten vertailua. Lisäksi pohdit- tiin mitkä perinteisten prosessointitapojen osiot rajoittavat tai edistävät ennustekykyä ja miten, sekä tuoko optimointi läpimurtoa järjestelmän näkökulmasta.Accurate pain assessment plays an important role in proper pain management, especially among hospitalized people experience acute pain. Pain is subjective in nature which is not only a sensory feeling but could also combine affective factors. Therefore self-report pain scales are the main assessment tools as long as patients are able to self-report. However, it remains a challenge to assess the pain from the patients who cannot self-report. In clinical practice, physiological parameters like heart rate and pain behaviors including facial expressions are observed as empirical references to infer pain objectively. The main aim of this study is to automate such process by leveraging machine learning methods and biosignal processing. To achieve this goal, biopotentials reflecting autonomic nervous system activities including electrocardiogram and galvanic skin response, and facial expressions measured with facial electromyograms were recorded from healthy volunteers undergoing experimental pain stimulus. IoT-enabled biopotential acquisition systems were developed to build the database aiming at providing compact and wearable solutions. Using the database, a biosignal processing flow was developed for continuous pain estimation. Signal features were extracted with customized time window lengths and updated every second. The extracted features were visualized and fed into multiple classifiers trained to estimate the presence of pain and pain intensity separately. Among the tested classifiers, the best pain presence estimating sensitivity achieved was 90% (specificity 84%) and the best pain intensity estimation accuracy achieved was 62.5%. The results show the validity of the proposed processing flow, especially in pain presence estimation at window level. This study adds one more piece of evidence on the feasibility of developing an automatic pain assessment tool from biopotentials, thus providing the confidence to move forward to real pain cases. In addition to the method development, the similarities and differences between automatic pain assessment studies were compared and summarized. It was found that in addition to the diversity of signals, the estimation goals also differed as a result of different study designs which made cross dataset comparison challenging. We also tried to discuss which parts in the classical processing flow would limit or boost the prediction performance and whether optimization can bring a breakthrough from the system’s perspective

    An integrated approach to whole-body vibration

    Get PDF
    Obiettivo di questa tesi è la determinazione e quantificazione degli effetti della whole-body vibration al corpo umano, in termini di consumo energetico, tramite un approccio globale e integrato. L’obiettivo è ottenuto considerando il corpo umano come una struttura organica complessa. Allo scopo di comprendere come questo risponda alle vibrazioni verticali, il consumo energetico del corpo umano è stato misurato per mezzo della variazione della temperatura superficiale con tecniche di misurazione a termografia infrarossa. Lo spostamento dei muscoli invece con il sistema di analisi di movimento Vicon MX. Infine, per quanto riguarda il consumo di ossigeno con il sistema telemetrico Cosmed K4. Il primo passo è stato l’istituzione di un protocollo appropriato che soddisfi l’obiettivo di questo studio. Infatti, la mancanza di coerenza nei protocollo di whole-body vibration che si trovano allo stato dell’arte, ha reso essenziale l’istituzione di un apposito protocollo, ed a questo scopo è stata definita la struttura dell’esperimento. Di conseguenza, è stata avviata una serie di prove per esaminare la risposta del corpo umano alle vibrazioni verticali, cambiando la durata e la frequenza della vibrazione, nonché la durata del periodo di riposo. In totale, quattro persone in piedi sono state sottoposte a vibrazioni verticali, in una pedana vibrante, a frequenze da 20 a 50 Hz. Dopo l’instaurazione del protocollo finale, sono stati avviate una serie di prove di laboratorio. In particolare, sono state scelte tre frequenze per le vibrazioni: 20, 30 e 45 Hz. I risultati ottenuti più interessanti di questo studio, riguardano il consumo di ossigeno, la temperatura superficiale e i coefficienti di trasmissibilità dell’accelerazione.The objective of this thesis is to determine and quantify the effects of whole-body vibration to the human body in terms of energy expenditure, by means of a global and integrated approach. This objective is attained by considering the human body as a complex organic structure. In order to understand how it responds to vertical vibrations, the energy expenditure of the human body was measured by means of the variation in superficial temperature with the aid of infrared thermography, the displacement of the muscles with the aid of the Vicon MX motion analysis system and the oxygen uptake with the aid of the Cosmed K4 telemetric system. The establishment of an appropriate protocol which satisfies the aim of this study was the first goal. The lack of consistency in whole-body vibration protocols in the current published studies makes the establishment of an appropriate protocol essential, and in this sense, an experiment setup was implemented. Therefore, a series of experiments was conducted to examine the response of the human body to vertical vibrations, changing the duration and the frequency of vertical vibration, and the duration of rest period. A number of four persons were subjected to vertical vibrations on a vibrating table in a standing position at a frequency ranging from 20 to 50 Hz. After the establishment of the final protocol, a series of laboratory experiments took place. Three different vibration frequencies were chosen: 20, 30 and 45 Hz corresponding to three different tests. The most interesting findings regard the oxygen consumption, the superficial temperature evolution, and the transmissibility coefficients for the acceleration

    Proceedings, MSVSCC 2018

    Get PDF
    Proceedings of the 12th Annual Modeling, Simulation & Visualization Student Capstone Conference held on April 19, 2018 at VMASC in Suffolk, Virginia. 155 pp

    Aerospace medicine and biology: A continuing bibliography with indexes, supplement 218, April 1981

    Get PDF
    This bibliography lists 161 reports, articles, and other documents introduced into the NASA scientific and technical information system in March 1981

    Control of Indoor Airflows for Reduction of Human Exposure to Aerosol Contaminants

    Get PDF
    corecore