4,768 research outputs found

    Distance Sensing with Dynamic Speckles

    Get PDF

    A Survey of Positioning Systems Using Visible LED Lights

    Get PDF
    © 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.As Global Positioning System (GPS) cannot provide satisfying performance in indoor environments, indoor positioning technology, which utilizes indoor wireless signals instead of GPS signals, has grown rapidly in recent years. Meanwhile, visible light communication (VLC) using light devices such as light emitting diodes (LEDs) has been deemed to be a promising candidate in the heterogeneous wireless networks that may collaborate with radio frequencies (RF) wireless networks. In particular, light-fidelity has a great potential for deployment in future indoor environments because of its high throughput and security advantages. This paper provides a comprehensive study of a novel positioning technology based on visible white LED lights, which has attracted much attention from both academia and industry. The essential characteristics and principles of this system are deeply discussed, and relevant positioning algorithms and designs are classified and elaborated. This paper undertakes a thorough investigation into current LED-based indoor positioning systems and compares their performance through many aspects, such as test environment, accuracy, and cost. It presents indoor hybrid positioning systems among VLC and other systems (e.g., inertial sensors and RF systems). We also review and classify outdoor VLC positioning applications for the first time. Finally, this paper surveys major advances as well as open issues, challenges, and future research directions in VLC positioning systems.Peer reviewe

    Applications of Silicon Retinas: from Neuroscience to Computer Vision

    Full text link
    Traditional visual sensor technology is firmly rooted in the concept of sequences of image frames. The sequence of stroboscopic images in these "frame cameras" is very different compared to the information running from the retina to the visual cortex. While conventional cameras have improved in the direction of smaller pixels and higher frame rates, the basics of image acquisition have remained the same. Event-based vision sensors were originally known as "silicon retinas" but are now widely called "event cameras." They are a new type of vision sensors that take inspiration from the mechanisms developed by nature for the mammalian retina and suggest a different way of perceiving the world. As in the neural system, the sensed information is encoded in a train of spikes, or so-called events, comparable to the action potential generated in the nerve. Event-based sensors produce sparse and asynchronous output that represents in- formative changes in the scene. These sensors have advantages in terms of fast response, low latency, high dynamic range, and sparse output. All these char- acteristics are appealing for computer vision and robotic applications, increasing the interest in this kind of sensor. However, since the sensor’s output is very dif- ferent, algorithms applied for frames need to be rethought and re-adapted. This thesis focuses on several applications of event cameras in scientific scenarios. It aims to identify where they can make the difference compared to frame cam- eras. The presented applications use the Dynamic Vision Sensor (event camera developed by the Sensors Group of the Institute of Neuroinformatics, University of Zurich and ETH). To explore some applications in more extreme situations, the first chapters of the thesis focus on the characterization of several advanced versions of the standard DVS. The low light condition represents a challenging situation for every vision sensor. Taking inspiration from standard Complementary Metal Oxide Semiconductor (CMOS) technology, the DVS pixel performances in a low light scenario can be improved, increasing sensitivity and quantum efficiency, by using back-side illumination. This thesis characterizes the so-called Back Side Illumination DAVIS (BSI DAVIS) camera and shows results from its application in calcium imaging of neural activity. The BSI DAVIS has shown better performance in the low light scene due to its high Quantum Efficiency (QE) of 93% and proved to be the best type of technology for microscopy application. The BSI DAVIS allows detecting fast dynamic changes in neural fluorescent imaging using the green fluorescent calcium indicator GCaMP6f. Event camera advances have pushed the exploration of event-based cameras in computer vision tasks. Chapters of this thesis focus on two of the most active research areas in computer vision: human pose estimation and hand gesture classification. Both chapters report the datasets collected to achieve the task, fulfilling the continuous need for data for this kind of new technology. The Dynamic Vision Sensor Human Pose dataset (DHP19) is an extensive collection of 33 whole-body human actions from 17 subjects. The chapter presents the first benchmark neural network model for 3D pose estimation using DHP19. The network archives a mean error of less than 8 mm in the 3D space, which is comparable with frame-based Human Pose Estimation (HPE) methods using frames. The gesture classification chapter reports an application running on a mobile device and explores future developments in the direction of embedded portable low power devices for online processing. The sparse output from the sensor suggests using a small model with a reduced number of parameters and low power consumption. The thesis also describes pilot results from two other scientific imaging applica- tions for raindrop size measurement and laser speckle analysis presented in the appendices

    Smart cmos image sensor for 3d measurement

    Get PDF
    3D measurements are concerned with extracting visual information from the geometry of visible surfaces and interpreting the 3D coordinate data thus obtained, to detect or track the position or reconstruct the profile of an object, often in real time. These systems necessitate image sensors with high accuracy of position estimation and high frame rate of data processing for handling large volumes of data. A standard imager cannot address the requirements of fast image acquisition and processing, which are the two figures of merit for 3D measurements. Hence, dedicated VLSI imager architectures are indispensable for designing these high performance sensors. CMOS imaging technology provides potential to integrate image processing algorithms on the focal plane of the device, resulting in smart image sensors, capable of achieving better processing features in handling massive image data. The objective of this thesis is to present a new architecture of smart CMOS image sensor for real time 3D measurement using the sheet-beam projection methods based on active triangulation. Proposing the vision sensor as an ensemble of linear sensor arrays, all working in parallel and processing the entire image in slices, the complexity of the image-processing task shifts from O (N 2 ) to O (N). Inherent also in the design is the high level of parallelism to achieve massive parallel processing at high frame rate, required in 3D computation problems. This work demonstrates a prototype of the smart linear sensor incorporating full testability features to test and debug both at device and system levels. The salient features of this work are the asynchronous position to pulse stream conversion, multiple images binarization, high parallelism and modular architecture resulting in frame rate and sub-pixel resolution suitable for real time 3D measurements

    Magnetocardiography with a modular spin-exchange relaxation free atomic magnetometer array

    Full text link
    We present a portable four-channel atomic magnetometer array operating in the spin exchange relaxation-free regime. The magnetometer array has several design features intended to maximize its suitability for biomagnetic measurement, specifically foetal magnetocardiography, such as a compact modular design, and fibre coupled lasers. The modular design allows the independent positioning and orientation of each magnetometer, in principle allowing for non-planar array geometries. Using this array in a magnetically shielded room, we acquire adult magnetocadiograms. These measurements were taken with a 6-11 fT Hz^(-1/2) single-channel baseline sensitivity that is consistent with the independently measured noise level of the magnetically shielded room.Comment: 15 pages, 5 figure

    A flexible sensor technology for the distributed measurement of interaction pressure

    Get PDF
    We present a sensor technology for the measure of the physical human-robot interaction pressure developed in the last years at Scuola Superiore Sant'Anna. The system is composed of flexible matrices of opto-electronic sensors covered by a soft silicone cover. This sensory system is completely modular and scalable, allowing one to cover areas of any sizes and shapes, and to measure different pressure ranges. In this work we present the main application areas for this technology. A first generation of the system was used to monitor human-robot interaction in upper- (NEUROExos; Scuola Superiore Sant'Anna) and lower-limb (LOPES; University of Twente) exoskeletons for rehabilitation. A second generation, with increased resolution and wireless connection, was used to develop a pressure-sensitive foot insole and an improved human-robot interaction measurement systems. The experimental characterization of the latter system along with its validation on three healthy subjects is presented here for the first time. A perspective on future uses and development of the technology is finally drafted

    Mass transfer enhancement produced by laser induced cavitation

    No full text
    A microelectrode is used to measure the mass transfer perturbation and characteristics during the growth and subsequent collapse of a single bubble (which, following its initial expansion, achieved a maximum radius, Rm, of not, vert, similar500–1000 ?m). This mass transfer enhancement was associated with the forced convection, driven by bubble motion, as the result of a single cavitation event generated by a laser pulse beneath a 25 ?m diameter Au microelectrode. Evidence for bubble growth and rebound is gained from the electrochemical and acoustic measurements. This is supported with high-speed video footage of the events generated. A threshold for the formation of large cavitation bubbles in electrolyte solutions is suggested

    Optical diffraction for measurements of nano-mechanical bending

    Get PDF
    Micromechanical transducers such as cantilevers for AFM often rely on optical readout methods that require illumination of a specific region of the microstructure. Here we explore and exploit the diffraction effects that have been previously neglected when modeling cantilever bending measurement techniques. The illumination of a cantilever end causes an asymmetric diffraction pattern at the photodetector that significantly affects the calibration of the signal in the popular optical beam deflection technique (OBDT). Conditions for optimized linear signals that avoid detection artifacts conflict with small numerical aperture illumination and narrow cantilevers which are softer and therefore more sensitive. Embracing diffraction patterns as a physical measurable allows a richer detection technique that decouples measurements of tilt and curvature and simultaneously relaxes the requirements on the alignment of illumination and detector. We show analytical results, numerical simulations and physiologically relevant experimental data demonstrating the usefulness of these diffraction features. We offer experimental design guidelines and identify and quantify possible sources of systematic error of up to 10% in OBDT. We demonstrate a new nanometre resolution detection method that can replace OBDT, where Frauenhofer and Bragg diffraction effects from finite sized and patterned cantilevers are exploited. Such effects are readily generalized to arrays, and allow transmission detection of mechanical curvature, enabling in-line instruments. In particular, a cantilever with a periodic array of slots produces Bragg peaks which can be analyzed to deduce the cantilever curvature. We highlight the comparative advantages over OBDT by detecting molecular activity of antibiotic Vancomycin, with an RMS noise equivalent to less than 2.5ÎĽM2.5 \mu M (1.5 nm), as example of possible multi-maker bio-assays.Comment: 9 pages, 8 figure
    • …
    corecore