3,796 research outputs found

    A Review of EMG Techniques for Detection of Gait Disorders

    Get PDF
    Electromyography (EMG) is a commonly used technique to record myoelectric signals, i.e., motor neuron signals that originate from the central nervous system (CNS) and synergistically activate groups of muscles resulting in movement. EMG patterns underlying movement, recorded using surface or needle electrodes, can be used to detect movement and gait abnormalities. In this review article, we examine EMG signal processing techniques that have been applied for diagnosing gait disorders. These techniques span from traditional statistical tests to complex machine learning algorithms. We particularly emphasize those techniques are promising for clinical applications. This study is pertinent to both medical and engineering research communities and is potentially helpful in advancing diagnostics and designing rehabilitation devices

    A morphology-based feature set for automated Amyotrophic Lateral Sclerosis diagnosis on surface electromyography

    Get PDF
    Funding Information: This work was supported by national funds from FCT Foundation for Science and Technology, Portugal , I.P. through the protect HomeSenseALS: Home-based monitoring of functional disability in amyotrophic lateral sclerosis with mobile sensing with reference PTDC/MEC-NEU/6855/2020 and research unit UIDB/FIS/04559/2020 (LIBPhys-UNL). Publisher Copyright: © 2022Amyotrophic Lateral Sclerosis (ALS) is a fast-progressing disease with no cure. Nowadays, needle electromyography (nEMG) is the standard practice for electrodiagnosis of ALS. Surface electromyography (sEMG) is emerging as a more practical and less painful alternative to nEMG but still has analytical and technical challenges. The objective of this work was to study the feasibility of using a set of morphological features extracted from sEMG to support a machine learning pipeline for ALS diagnosis. We developed a novel feature set to characterize sEMG based on quantitative measurements to surface representation of Motor Unit Action Potentials. We conducted several experiments to study the relevance of the proposed feature set either individually or combined with conventional feature sets from temporal, statistical, spectral, and fractal domains. We validated the proposed machine learning pipeline on a dataset with sEMG upper limb muscle data from 17 ALS patients and 24 control subjects. The results support the utility of the proposed feature set, achieving an F1 score of (81.9 ± 5.7) for the onset classification approach and (83.6 ± 6.9) for the subject classification approach, solely relying on features extracted from the proposed feature set in the right first dorsal interosseous muscle. We concluded that introducing the proposed feature set is relevant for automated ALS diagnosis since it increased the classifier performance during our experiments. The proposed feature set might also help design more interpretable classifiers as the features give additional information related to the nature of the disease, being inspired by the clinical interpretation of sEMG.publishersversionpublishe

    Review of medical data analysis based on spiking neural networks

    Full text link
    Medical data mainly includes various types of biomedical signals and medical images, which can be used by professional doctors to make judgments on patients' health conditions. However, the interpretation of medical data requires a lot of human cost and there may be misjudgments, so many scholars use neural networks and deep learning to classify and study medical data, which can improve the efficiency and accuracy of doctors and detect diseases early for early diagnosis, etc. Therefore, it has a wide range of application prospects. However, traditional neural networks have disadvantages such as high energy consumption and high latency (slow computation speed). This paper presents recent research on signal classification and disease diagnosis based on a third-generation neural network, the spiking neuron network, using medical data including EEG signals, ECG signals, EMG signals and MRI images. The advantages and disadvantages of pulsed neural networks compared with traditional networks are summarized and its development orientation in the future is prospected

    Upper Limb Movement Recognition utilising EEG and EMG Signals for Rehabilitative Robotics

    Full text link
    Upper limb movement classification, which maps input signals to the target activities, is a key building block in the control of rehabilitative robotics. Classifiers are trained for the rehabilitative system to comprehend the desires of the patient whose upper limbs do not function properly. Electromyography (EMG) signals and Electroencephalography (EEG) signals are used widely for upper limb movement classification. By analysing the classification results of the real-time EEG and EMG signals, the system can understand the intention of the user and predict the events that one would like to carry out. Accordingly, it will provide external help to the user. However, the noise in the real-time EEG and EMG data collection process contaminates the effectiveness of the data, which undermines classification performance. Moreover, not all patients process strong EMG signals due to muscle damage and neuromuscular disorder. To address these issues, this paper explores different feature extraction techniques and machine learning and deep learning models for EEG and EMG signals classification and proposes a novel decision-level multisensor fusion technique to integrate EEG signals with EMG signals. This system retrieves effective information from both sources to understand and predict the desire of the user, and thus aid. By testing out the proposed technique on a publicly available WAY-EEG-GAL dataset, which contains EEG and EMG signals that were recorded simultaneously, we manage to conclude the feasibility and effectiveness of the novel system.Comment: 20 pages, 11 figures, 2 tables; Thesis for Undergraduate Research Project in Computing, NUS; Accepted by Future of Information and Communication Conference 2023, San Francisc

    Biosignal‐based human–machine interfaces for assistance and rehabilitation : a survey

    Get PDF
    As a definition, Human–Machine Interface (HMI) enables a person to interact with a device. Starting from elementary equipment, the recent development of novel techniques and unobtrusive devices for biosignals monitoring paved the way for a new class of HMIs, which take such biosignals as inputs to control various applications. The current survey aims to review the large literature of the last two decades regarding biosignal‐based HMIs for assistance and rehabilitation to outline state‐of‐the‐art and identify emerging technologies and potential future research trends. PubMed and other databases were surveyed by using specific keywords. The found studies were further screened in three levels (title, abstract, full‐text), and eventually, 144 journal papers and 37 conference papers were included. Four macrocategories were considered to classify the different biosignals used for HMI control: biopotential, muscle mechanical motion, body motion, and their combinations (hybrid systems). The HMIs were also classified according to their target application by considering six categories: prosthetic control, robotic control, virtual reality control, gesture recognition, communication, and smart environment control. An ever‐growing number of publications has been observed over the last years. Most of the studies (about 67%) pertain to the assistive field, while 20% relate to rehabilitation and 13% to assistance and rehabilitation. A moderate increase can be observed in studies focusing on robotic control, prosthetic control, and gesture recognition in the last decade. In contrast, studies on the other targets experienced only a small increase. Biopotentials are no longer the leading control signals, and the use of muscle mechanical motion signals has experienced a considerable rise, especially in prosthetic control. Hybrid technologies are promising, as they could lead to higher performances. However, they also increase HMIs’ complex-ity, so their usefulness should be carefully evaluated for the specific application

    Support vector machines to detect physiological patterns for EEG and EMG-based human-computer interaction:a review

    Get PDF
    Support vector machines (SVMs) are widely used classifiers for detecting physiological patterns in human-computer interaction (HCI). Their success is due to their versatility, robustness and large availability of free dedicated toolboxes. Frequently in the literature, insufficient details about the SVM implementation and/or parameters selection are reported, making it impossible to reproduce study analysis and results. In order to perform an optimized classification and report a proper description of the results, it is necessary to have a comprehensive critical overview of the applications of SVM. The aim of this paper is to provide a review of the usage of SVM in the determination of brain and muscle patterns for HCI, by focusing on electroencephalography (EEG) and electromyography (EMG) techniques. In particular, an overview of the basic principles of SVM theory is outlined, together with a description of several relevant literature implementations. Furthermore, details concerning reviewed papers are listed in tables and statistics of SVM use in the literature are presented. Suitability of SVM for HCI is discussed and critical comparisons with other classifiers are reported

    The status of textile-based dry EEG electrodes

    Get PDF
    Electroencephalogram (EEG) is the biopotential recording of electrical signals generated by brain activity. It is useful for monitoring sleep quality and alertness, clinical applications, diagnosis, and treatment of patients with epilepsy, disease of Parkinson and other neurological disorders, as well as continuous monitoring of tiredness/ alertness in the field. We provide a review of textile-based EEG. Most of the developed textile-based EEGs remain on shelves only as published research results due to a limitation of flexibility, stickability, and washability, although the respective authors of the works reported that signals were obtained comparable to standard EEG. In addition, nearly all published works were not quantitatively compared and contrasted with conventional wet electrodes to prove feasibility for the actual application. This scenario would probably continue to give a publication credit, but does not add to the growth of the specific field, unless otherwise new integration approaches and new conductive polymer composites are evolved to make the application of textile-based EEG happen for bio-potential monitoring

    Surface Electromyography and Artificial Intelligence for Human Activity Recognition - A Systematic Review on Methods, Emerging Trends Applications, Challenges, and Future Implementation

    Get PDF
    Human activity recognition (HAR) has become increasingly popular in recent years due to its potential to meet the growing needs of various industries. Electromyography (EMG) is essential in various clinical and biological settings. It is a metric that helps doctors diagnose conditions that affect muscle activation patterns and monitor patients’ progress in rehabilitation, disease diagnosis, motion intention recognition, etc. This review summarizes the various research papers based on HAR with EMG. Over recent years, the integration of Artificial Intelligence (AI) has catalyzed remarkable advancements in the classification of biomedical signals, with a particular focus on EMG data. Firstly, this review meticulously curates a wide array of research papers that have contributed significantly to the evolution of EMG-based activity recognition. By surveying the existing literature, we provide an insightful overview of the key findings and innovations that have propelled this field forward. It explore the various approaches utilized for preprocessing EMG signals, including noise reduction, baseline correction, filtering, and normalization, ensure that the EMG data is suitably prepared for subsequent analysis. In addition, we unravel the multitude of techniques employed to extract meaningful features from raw EMG data, encompassing both time-domain and frequency-domain features. These techniques are fundamental to achieving a comprehensive characterization of muscle activity patterns. Furthermore, we provide an extensive overview of both Machine Learning (ML) and Deep Learning (DL) classification methods, showcasing their respective strengths, limitations, and real-world applications in recognizing diverse human activities from EMG signals. In examining the hardware infrastructure for HAR with EMG, the synergy between hardware and software is underscored as paramount for enabling real-time monitoring. Finally, we also discovered open issues and future research direction that may point to new lines of inquiry for ongoing research toward EMG-based detection.publishedVersio
    • 

    corecore