    Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review.

    Get PDF
    Breathing rate (BR) is a key physiological parameter used in a range of clinical settings. Despite its diagnostic and prognostic value, it is still widely measured by counting breaths manually. A plethora of algorithms have been proposed to estimate BR from the electrocardiogram (ECG) and pulse oximetry (photoplethysmogram, PPG) signals. These BR algorithms provide opportunity for automated, electronic, and unobtrusive measurement of BR in both healthcare and fitness monitoring. This paper presents a review of the literature on BR estimation from the ECG and PPG. First, the structure of BR algorithms and the mathematical techniques used at each stage are described. Second, the experimental methodologies that have been used to assess the performance of BR algorithms are reviewed, and a methodological framework for the assessment of BR algorithms is presented. Third, we outline the most pressing directions for future research, including the steps required to use BR algorithms in wearable sensors, remote video monitoring, and clinical practice

    Wearable in-ear pulse oximetry: theory and applications

    Get PDF
    Wearable health technology, most commonly in the form of the smart watch, is employed by millions of users worldwide. These devices generally exploit photoplethysmography (PPG), the non-invasive use of light to measure blood volume, in order to track physiological metrics such as pulse and respiration. Moreover, PPG is commonly used in hospitals in the form of pulse oximetry, which measures light absorbance by the blood at different wavelengths of light to estimate blood oxygen levels (SpO2). This thesis aims to demonstrate that despite its widespread usage over many decades, this sensor still possesses a wealth of untapped value. Through a combination of advanced signal processing and harnessing the ear as a location for wearable sensing, this thesis introduces several novel high impact applications of in-ear pulse oximetry and photoplethysmography. The aims of this thesis are accomplished through a three pronged approach: rapid detection of hypoxia, tracking of cognitive workload and fatigue, and detection of respiratory disease. By means of the simultaneous recording of in-ear and finger pulse oximetry at rest and during breath hold tests, it was found that in-ear SpO2 responds on average 12.4 seconds faster than the finger SpO2. This is likely due in part to the ear being in close proximity to the brain, making it a priority for oxygenation and thus making wearable in-ear SpO2 a good proxy for core blood oxygen. Next, the low latency of in-ear SpO2 was further exploited in the novel application of classifying cognitive workload. It was found that in-ear pulse oximetry was able to robustly detect tiny decreases in blood oxygen during increased cognitive workload, likely caused by increased brain metabolism. This thesis demonstrates that in-ear SpO2 can be used to accurately distinguish between different levels of an N-back memory task, representing different levels of mental effort. This concept was further validated through its application to gaming and then extended to the detection of driver related fatigue. It was found that features derived from SpO2 and PPG were predictive of absolute steering wheel angle, which acts as a proxy for fatigue. The strength of in-ear PPG for the monitoring of respiration was investigated with respect to the finger, with the conclusion that in-ear PPG exhibits far stronger respiration induced intensity variations and pulse amplitude variations than the finger. All three respiratory modes were harnessed through multivariate empirical mode decomposition (MEMD) to produce spirometry-like respiratory waveforms from PPG. It was discovered that these PPG derived respiratory waveforms can be used to detect obstruction to breathing, both through a novel apparatus for the simulation of breathing disorders and through the classification of chronic obstructive pulmonary disease (COPD) in the real world. This thesis establishes in-ear pulse oximetry as a wearable technology with the potential for immense societal impact, with applications from the classification of cognitive workload and the prediction of driver fatigue, through to the detection of chronic obstructive pulmonary disease. The experiments and analysis in this thesis conclusively demonstrate that widely used pulse oximetry and photoplethysmography possess a wealth of untapped value, in essence teaching the old PPG sensor new tricks.Open Acces

    Rapid Extraction of Respiratory Waveforms from Photoplethysmography: A Deep Encoder Approach

    Full text link
    Much of the information of breathing is contained within the photoplethysmography (PPG) signal, through changes in venous blood flow, heart rate and stroke volume. We aim to leverage this fact, by employing a novel deep learning framework which is a based on a repurposed convolutional autoencoder. Our model aims to encode all of the relevant respiratory information contained within photoplethysmography waveform, and decode it into a waveform that is similar to a gold standard respiratory reference. The model is employed on two photoplethysmography data sets, namely Capnobase and BIDMC. We show that the model is capable of producing respiratory waveforms that approach the gold standard, while in turn producing state of the art respiratory rate estimates. We also show that when it comes to capturing more advanced respiratory waveform characteristics such as duty cycle, our model is for the most part unsuccessful. A suggested reason for this, in light of a previous study on in-ear PPG, is that the respiratory variations in finger-PPG are far weaker compared with other recording locations. Importantly, our model can perform these waveform estimates in a fraction of a millisecond, giving it the capacity to produce over 6 hours of respiratory waveforms in a single second. Moreover, we attempt to interpret the behaviour of the kernel weights within the model, showing that in part our model intuitively selects different breathing frequencies. The model proposed in this work could help to improve the usefulness of consumer PPG-based wearables for medical applications, where detailed respiratory information is required

    Wearable in-ear PPG: detailed respiratory variations enable classification of COPD

    Get PDF
    An ability to extract detailed spirometry-like breath-ing waveforms from wearable sensors promises to greatly improve respiratory health monitoring. Photoplethysmography (PPG) has been researched in depth for estimation of respiration rate, given that it varies with respiration through overall intensity, pulse amplitude and pulse interval. We compare and contrast the extraction of these three respiratory modes from both the ear canal and finger and show a marked improvement in the respiratory power for respiration induced intensity variations and pulse amplitude variations when recording from the ear canal. We next employ a data driven multi-scale method, noise assisted multivariate empirical mode decomposition (NA-MEMD), which allows for simultaneous analysis of all three respiratory modes to extract detailed respiratory waveforms from in-ear PPG. For rigour, we considered in-ear PPG recordings from healthy subjects, both older and young, patients with chronic obstructive pulmonary disease (COPD) and idiopathic pulmonary fibrosis (IPF) and healthy subjects with artificially obstructed breathing. Specific in-ear PPG waveform changes are observed for COPD, such as a decreased inspiratory duty cycle and an increased inspiratory magnitude, when compared with expiratory magnitude. These differences are used to classify COPD from healthy and IPF waveforms with a sensitivity of 87% and an overall accuracy of 92%. Our findings indicate the promise of in-ear PPG for COPD screening and unobtrusive respiratory monitoring in ambulatory scenarios and in consumer wearables

    Development of Respiratory Rate Estimation Technique Using Electrocardiogram and Photoplethysmogram for Continuous Health Monitoring

    Get PDF
    Abnormal vital signs often predict a serious condition of acutely ill hospital patients in 24 hours. The notable fluctuations of respiratory rate (RR) are highly predictive of deteriorations among the vital signs measured. Traditional methods of detecting RR are performed by directly measuring the air flow in or out of the lungs or indirectly measuring the changes of the chest volume. These methods require the use of cumbersome devices, which may interfere with natural breathing, are uncomfortable, have frequently moving artifacts, and are extremely expensive. This study aims to estimate the RR from electrocardiogram (ECG) and photoplethysmogram (PPG) signals, which consist of passive and non-invasive acquisition modules. Algorithms have been validated by using PhysioNet’s Multiparameter Intelligent Monitoring in Intensive Care II (MIMIC-II)’s patient datasets. RR estimation provides the value of mean absolute error (MAE) for ECG as 1.25 bpm (MIMIC-II) and 1.05 bpm for the acquired data. MAE for PPG is 1.15 bpm (MIMIC-II) and 0.90 bpm for the acquired data. By using 1-minute windows, this method reveals that the filtering method efficiently extracted respiratory information from the ECG and PPG signals. Smaller MAE for PPG signals results from fewer artifacts due to easy sensor attachment for the PPG because PPG recording requires only one-finger pulse oximeter sensor placement. However, ECG recording requires at least three electrode placements at three positions on the subject’s body surface for a single lead (lead II), thereby increasing the artifacts. A reliable technique has been proposed for RR estimation

    Comparison Of Two Methods For Demodulation Of Pulse Signals - Application In Case Of Central Sleep Apnea

    Get PDF
    In the field of 24/7 human health monitoring, pervasive computing makes possible the continuous analysis of physiological parameters from an ambulatory device with a great acceptability. This paper presents two methods for obtaining cardiac and respiratory rates from a single arterial pressure signal: AM-FM demodulation and Singular Spectrum Analysis (SSA). With the aim to monitor sleep apnea, two simulated central sleep apnea were performed and recorded with Biopac reference system. The results showed a good evaluation of the cardiac rate with Singular Spectrum Analysis and bad results with AM-FM demodulation. For the respiration rate, some other signals were tested with average results for both methods. Further experiments will deal with real sleep apnea cases and algorithm improvements