31 research outputs found

    Denoising sparse images from GRAPPA using the nullspace method

    Get PDF
    To accelerate magnetic resonance imaging using uniformly undersampled (nonrandom) parallel imaging beyond what is achievable with generalized autocalibrating partially parallel acquisitions (GRAPPA) alone, the DEnoising of Sparse Images from GRAPPA using the Nullspace method is developed. The trade-off between denoising and smoothing the GRAPPA solution is studied for different levels of acceleration. Several brain images reconstructed from uniformly undersampled k-space data using DEnoising of Sparse Images from GRAPPA using the Nullspace method are compared against reconstructions using existing methods in terms of difference images (a qualitative measure), peak-signal-to-noise ratio, and noise amplification (g-factors) as measured using the pseudo-multiple replica method. Effects of smoothing, including contrast loss, are studied in synthetic phantom data. In the experiments presented, the contrast loss and spatial resolution are competitive with existing methods. Results for several brain images demonstrate significant improvements over GRAPPA at high acceleration factors in denoising performance with limited blurring or smoothing artifacts. In addition, the measured g-factors suggest that DEnoising of Sparse Images from GRAPPA using the Nullspace method mitigates noise amplification better than both GRAPPA and L1 iterative self-consistent parallel imaging reconstruction (the latter limited here by uniform undersampling).National Science Foundation (U.S.) (CAREER Grant 0643836)National Institutes of Health (U.S.) (Grant NIH R01 EB007942)National Institutes of Health (U.S.) (Grant NIH R01 EB006847)National Center for Research Resources (U.S.) (Grant P41 RR014075)Siemens CorporationNational Science Foundation (U.S.). Graduate Research Fellowship Progra

    DAGAN: deep de-aliasing generative adversarial networks for fast compressed sensing MRI reconstruction

    Get PDF
    Compressed Sensing Magnetic Resonance Imaging (CS-MRI) enables fast acquisition, which is highly desirable for numerous clinical applications. This can not only reduce the scanning cost and ease patient burden, but also potentially reduce motion artefacts and the effect of contrast washout, thus yielding better image quality. Different from parallel imaging based fast MRI, which utilises multiple coils to simultaneously receive MR signals, CS-MRI breaks the Nyquist-Shannon sampling barrier to reconstruct MRI images with much less required raw data. This paper provides a deep learning based strategy for reconstruction of CS-MRI, and bridges a substantial gap between conventional non-learning methods working only on data from a single image, and prior knowledge from large training datasets. In particular, a novel conditional Generative Adversarial Networks-based model (DAGAN) is proposed to reconstruct CS-MRI. In our DAGAN architecture, we have designed a refinement learning method to stabilise our U-Net based generator, which provides an endto-end network to reduce aliasing artefacts. To better preserve texture and edges in the reconstruction, we have coupled the adversarial loss with an innovative content loss. In addition, we incorporate frequency domain information to enforce similarity in both the image and frequency domains. We have performed comprehensive comparison studies with both conventional CSMRI reconstruction methods and newly investigated deep learning approaches. Compared to these methods, our DAGAN method provides superior reconstruction with preserved perceptual image details. Furthermore, each image is reconstructed in about 5 ms, which is suitable for real-time processing

    Rekonstrukcija signala iz nepotpunih merenja sa primenom u ubrzanju algoritama za rekonstrukciju slike magnetne rezonance

    Get PDF
    In dissertation a problem of reconstruction of images from undersampled measurements is considered which has direct application in creation of magnetic resonance images. The topic of the research is proposition of new regularization based methods for image reconstruction which are based on statistical Markov random field models and theory of compressive sensing. With the proposed signal model which follows the statistics of images, a new regularization functions are defined and four methods for reconstruction of magnetic resonance images are derived.У докторској дисертацији разматран је проблем реконструкције сигнала слике из непотпуних мерења који има директну примену у креирању слика магнетне резнонаце. Предмет истраживања је везан за предлог нових регуларизационих метода реконструкције коришћењем статистичких модела Марковљевог случајног поља и теорије ретке репрезентације сигнала. На основу предложеног модела који на веродостојан начин репрезентује статистику сигнала слике предложене су регуларизационе функције и креирана четири алгоритма за реконструкцију слике магнетне резонанце.U doktorskoj disertaciji razmatran je problem rekonstrukcije signala slike iz nepotpunih merenja koji ima direktnu primenu u kreiranju slika magnetne reznonace. Predmet istraživanja je vezan za predlog novih regularizacionih metoda rekonstrukcije korišćenjem statističkih modela Markovljevog slučajnog polja i teorije retke reprezentacije signala. Na osnovu predloženog modela koji na verodostojan način reprezentuje statistiku signala slike predložene su regularizacione funkcije i kreirana četiri algoritma za rekonstrukciju slike magnetne rezonance

    Sparse MRI and CT Reconstruction

    Full text link
    Sparse signal reconstruction is of the utmost importance for efficient medical imaging, conducting accurate screening for security and inspection, and for non-destructive testing. The sparsity of the signal is dictated by either feasibility, or the cost and the screening time constraints of the system. In this work, two major sparse signal reconstruction systems such as compressed sensing magnetic resonance imaging (MRI) and sparse-view computed tomography (CT) are investigated. For medical CT, a limited number of views (sparse-view) is an option for whether reducing the amount of ionizing radiation or the screening time and the cost of the procedure. In applications such as non-destructive testing or inspection of large objects, like a cargo container, one angular view can take up to a few minutes for only one slice. On the other hand, some views can be unavailable due to the configuration of the system. A problem of data sufficiency and on how to estimate a tomographic image when the projection data are not ideally sufficient for precise reconstruction is one of two major objectives of this work. Three CT reconstruction methods are proposed: algebraic iterative reconstruction-reprojection (AIRR), sparse-view CT reconstruction based on curvelet and total variation regularization (CTV), and sparse-view CT reconstruction based on nonconvex L1-L2 regularization. The experimental results confirm a high performance based on subjective and objective quality metrics. Additionally, sparse-view neutron-photon tomography is studied based on Monte-Carlo modelling to demonstrate shape reconstruction, material discrimination and visualization based on the proposed 3D object reconstruction method and material discrimination signatures. One of the methods for efficient acquisition of multidimensional signals is the compressed sensing (CS). A significantly low number of measurements can be obtained in different ways, and one is undersampling, that is sampling below the Shannon-Nyquist limit. Magnetic resonance imaging (MRI) suffers inherently from its slow data acquisition. The compressed sensing MRI (CSMRI) offers significant scan time reduction with advantages for patients and health care economics. In this work, three frameworks are proposed and evaluated, i.e., CSMRI based on curvelet transform and total generalized variation (CT-TGV), CSMRI using curvelet sparsity and nonlocal total variation: CS-NLTV, CSMRI that explores shearlet sparsity and nonlocal total variation: SS-NLTV. The proposed methods are evaluated experimentally and compared to the previously reported state-of-the-art methods. Results demonstrate a significant improvement of image reconstruction quality on different medical MRI datasets

    Compressed Sensing For Functional Magnetic Resonance Imaging Data

    Get PDF
    This thesis addresses the possibility of applying the compressed sensing (CS) framework to Functional Magnetic Resonance Imaging (fMRI) acquisition. The fMRI is one of the non-invasive neuroimaging technique that allows the brain activity to be captured and analysed in a living body. One disadvantage of fMRI is the trade-off between the spatial and temporal resolution of the data. To keep the experiments within a reasonable length of time, the current acquisition technique sacrifices the spatial resolution in favour of the temporal resolution. It is possible to improve this trade-off using compressed sensing. The main contribution of this thesis is to propose a novel reconstruction method, named Referenced Compressed Sensing, which exploits the redundancy between a signal and a correlated reference by using their distance as an objective function. The compressed video sequences reconstructed using Referenced CS have at least 50% higher in terms of Peak Signal-to-Noise Ratio (PSNR) compared to state-of-the-art conventional reconstruction methods. This thesis also addresses two issues related to Referenced CS. Firstly, the relationship between the reference and the reconstruction performance is studied. To maintain the high-quality references, the Running Gaussian Average (RGA) reference estimator is proposed. The reconstructed results have at least 3dB better PSNR performance with the use of RGA references. Secondly, the Referenced CS with Least Squares is proposed. This study shows that by incorporating the correlated reference, it is possible to perform a linear reconstruction as opposed to the iterative reconstruction commonly used in CS. This approach gives at least 19% improvement in PSNR compared to the state of the art, while reduces the computation time by at most 1200 times. The proposed method is applied to the fMRI data. This study shows that, using the same amount of samples, the data reconstructed using Referenced CS has higher resolution than the conventional acquisition technique and has on average 50% higher PSNR than state-of-the-art reconstructions. Lastly, to enhance the feature of interest in the fMRI data, the baseline independent (BI) analysis is proposed. Using the BI analysis shows up to 25% improvement in the accuracy of the Referenced CS feature

    Improving the image quality in compressed sensing MRI by the exploitation of data properties

    Get PDF

    Fast Acquisition and Reconstruction Techniques in MRI

    Get PDF
    The aim of this thesis was to develop fast reconstruction and acquisition techniques for MRI that can support clinical applications where time is a limiting factor. In general, fast acquisition techniques were realized by undersampling k-space, while fast reconstruction techniques were achieved by using efficient numerical algorithms. In particular, undersampled acquisitions were processed in a CS and MRF framework. Preconditioning techniques were used to accelerate CS reconstructions, and a number of challenges encountered in MRF were addressed using appropriate post-processing techniques. European Research Council (ERC) Advanced Grant (670629 NOMA MRI)LUMC / Geneeskund
    corecore