    Dual-side and three-dimensional microelectrode arrays fabricated from ultra-thin silicon substrates

    Get PDF
    A method for fabricating planar implantable microelectrode arrays was demonstrated using a process that relied on ultra-thin silicon substrates, which ranged in thickness from 25 to 50 µm. The challenge of handling these fragile materials was met via a temporary substrate support mechanism. In order to compensate for putative electrical shielding of extracellular neuronal fields, separately addressable electrode arrays were defined on each side of the silicon device. Deep reactive ion etching was employed to create sharp implantable shafts with lengths of up to 5 mm. The devices were flip-chip bonded onto printed circuit boards (PCBs) by means of an anisotropic conductive adhesive film. This scalable assembly technique enabled three-dimensional (3D) integration through formation of stacks of multiple silicon and PCB layers. Simulations and measurements of microelectrode noise appear to suggest that low impedance surfaces, which could be formed by electrodeposition of gold or other materials, are required to ensure an optimal signal-to-noise ratio as well a low level of interchannel crosstalk

    Development of a Three Dimensional Neural Sensing Device by a Stacking Method

    Get PDF
    This study reports a new stacking method for assembling a 3-D microprobe array. To date, 3-D array structures have usually been assembled with vertical spacers, snap fasteners and a supporting platform. Such methods have achieved 3-D structures but suffer from complex assembly steps, vertical interconnection for 3-D signal transmission, low structure strength and large implantable opening. By applying the proposed stacking method, the previous techniques could be replaced by 2-D wire bonding. In this way, supporting platforms with slots and vertical spacers were no longer needed. Furthermore, ASIC chips can be substituted for the spacers in the stacked arrays to achieve system integration, design flexibility and volume usage efficiency. To avoid overflow of the adhesive fluid during assembly, an anti-overflow design which made use of capillary action force was applied in the stacking method as well. Moreover, presented stacking procedure consumes only 35 minutes in average for a 4 × 4 3-D microprobe array without requiring other specially made assembly tools. To summarize, the advantages of the proposed stacking method for 3-D array assembly include simplified assembly process, high structure strength, smaller opening area and integration ability with active circuits. This stacking assembly technique allows an alternative method to create 3-D structures from planar components

    A Multimodal, SU-8-Platinum - Polyimide Microelectrode Array for Chronic In Vivo Neurophysiology

    Get PDF
    Utilization of polymers as insulator and bulk materials of microelectrode arrays (MEAs) makes the realization of flexible, biocompatible sensors possible, which are suitable for various neurophysiological experiments such as in vivo detection of local field potential changes on the surface of the neocortex or unit activities within the brain tissue. In this paper the microfabrication of a novel, all-flexible, polymer-based MEA is presented. The device consists of a three dimensional sensor configuration with an implantable depth electrode array and brain surface electrodes, allowing the recording of electrocorticographic (ECoG) signals with laminar ones, simultaneously. In vivo recordings were performed in anesthetized rat brain to test the functionality of the device under both acute and chronic conditions. The ECoG electrodes recorded slow-wave thalamocortical oscillations, while the implanted component provided high quality depth recordings. The implants remained viable for detecting action potentials of individual neurons for at least 15 weeks

    Curvy surface conformal ultra-thin transfer printed Si optoelectronic penetrating microprobe arrays

    Get PDF
    Penetrating neural probe arrays are powerful bio-integrated devices for studying basic neuroscience and applied neurophysiology, underlying neurological disorders, and understanding and regulating animal and human behavior. This paper presents a penetrating microprobe array constructed in thin and flexible fashion, which can be seamlessly integrated with the soft curvy substances. The function of the microprobes is enabled by transfer printed ultra-thin Si optoelectronics. As a proof-of-concept device, microprobe array with Si photodetector arrays are demonstrated and their capability of mapping the photo intensity in space are illustrated. The design strategies of utilizing thin polyimide based microprobes and supporting substrate, and employing the heterogeneously integrated thin optoelectronics are keys to accomplish such a device. The experimental and theoretical investigations illustrate the materials, manufacturing, mechanical and optoelectronic aspects of the device. While this paper primarily focuses on the device platform development, the associated materials, manufacturing technologies, and device design strategy are applicable to more complex and multi-functionalities in penetrating probe array-based neural interfaces and can also find potential utilities in a wide range of bio-integrated systems

    High-resolution three-dimensional extracellular recording of neuronal activity with microfabricated electrode arrays

    Get PDF
    Microelectrode array recordings of neuronal activity present significant opportunities for studying the brain with single-cell and spike-time precision. However, challenges in device manufacturing constrain dense multisite recordings to two spatial dimensions, whereas access to the three-dimensional (3D) structure of many brain regions appears to remain a challenge. To overcome this limitation, we present two novel recording modalities of silicon-based devices aimed at establishing 3D functionality. First, we fabricated a dual-side electrode array by patterning recording sites on both the front and back of an implantable microstructure. We found that the majority of single-unit spikes could not be simultaneously detected from both sides, suggesting that in addition to providing higher spatial resolution measurements than that of single-side devices, dual-side arrays also lead to increased recording yield. Second, we obtained recordings along three principal directions with a multilayer array and demonstrated 3D spike source localization within the enclosed measurement space. The large-scale integration of such dual-side and multilayer arrays is expected to provide massively parallel recording capabilities in the brain

    Multisite monitoring of choline using biosensor microprobe arrays in combination with CMOS circuitry

    Get PDF
    A miniature device enabling parallel in vivo detection of the neurotransmitter choline in multiple brain regions of freely behaving rodents is presented. This is achieved by combining a biosensor microprobe array with a custom-developed CMOS chip. Each silicon microprobe comprises multiple platinum electrodes that are coated with an enzymatic membrane and a permselective layer for selective detection of choline. The biosensors, based on the principle of amperometric detection, exhibit a sensitivity of 157±35 µA mM-1 cm-2, a limit of detection of below 1 µM, and a response time in the range of 1 s. With on-chip digitalization and multiplexing, parallel recordings can be performed at a high signal-to-noise ratio with minimal space requirements and with substantial reduction of external signal interference. The layout of the integrated circuitry allows for versatile configuration of the current range and can, therefore, also be used for functionalization of the electrodes before use. The result is a compact, highly integrated system, very convenient for on-site measurement

    Micromachined three-dimensional electrode arrays for in-vitro and in-vivo electrogenic cellular networks

    Get PDF
    This dissertation presents an investigation of micromachined three-dimensional microelectrode arrays (3-D MEAs) targeted toward in-vitro and in-vivo biomedical applications. Current 3-D MEAs are predominantly silicon-based, fabricated in a planar fashion, and are assembled to achieve a true 3-D form: a technique that cannot be extended to micro-manufacturing. The integrated 3-D MEAs developed in this work are polymer-based and thus offer potential for large-scale, high volume manufacturing. Two different techniques are developed for microfabrication of these MEAs - laser micromachining of a conformally deposited polymer on a non-planar surface to create 3-D molds for metal electrodeposition; and metal transfer micromolding, where functional metal layers are transferred from one polymer to another during the process of micromolding thus eliminating the need for complex and non-repeatable 3-D lithography processes. In-vitro and in-vivo 3-D MEAs are microfabricated using these techniques and are packaged utilizing Printed Circuit Boards (PCB) or other low-cost manufacturing techniques. To demonstrate in-vitro applications, growth of 3-D co-cultures of neurons/astrocytes and tissue-slice electrophysiology with brain tissue of rat pups were implemented. To demonstrate in-vivo application, measurements of nerve conduction were implemented. Microelectrode impedance models, noise models and various process models were evaluated. The results confirmed biocompatibility of the polymers involved, acceptable impedance range and noise of the microelectrodes, and potential to improve upon an archaic clinical diagnostic application utilizing these 3-D MEAs.Ph.D.Committee Chair: Mark G. Allen; Committee Member: Elliot L. Chaikof; Committee Member: Ionnis (John) Papapolymerou; Committee Member: Maysam Ghovanloo; Committee Member: Oliver Bran
    corecore