120 research outputs found

    Assessing the quality of steady-state visual-evoked potentials for moving humans using a mobile electroencephalogram headset.

    Get PDF
    Recent advances in mobile electroencephalogram (EEG) systems, featuring non-prep dry electrodes and wireless telemetry, have enabled and promoted the applications of mobile brain-computer interfaces (BCIs) in our daily life. Since the brain may behave differently while people are actively situated in ecologically-valid environments versus highly-controlled laboratory environments, it remains unclear how well the current laboratory-oriented BCI demonstrations can be translated into operational BCIs for users with naturalistic movements. Understanding inherent links between natural human behaviors and brain activities is the key to ensuring the applicability and stability of mobile BCIs. This study aims to assess the quality of steady-state visual-evoked potentials (SSVEPs), which is one of promising channels for functioning BCI systems, recorded using a mobile EEG system under challenging recording conditions, e.g., walking. To systematically explore the effects of walking locomotion on the SSVEPs, this study instructed subjects to stand or walk on a treadmill running at speeds of 1, 2, and 3 mile (s) per hour (MPH) while concurrently perceiving visual flickers (11 and 12 Hz). Empirical results of this study showed that the SSVEP amplitude tended to deteriorate when subjects switched from standing to walking. Such SSVEP suppression could be attributed to the walking locomotion, leading to distinctly deteriorated SSVEP detectability from standing (84.87 ± 13.55%) to walking (1 MPH: 83.03 ± 13.24%, 2 MPH: 79.47 ± 13.53%, and 3 MPH: 75.26 ± 17.89%). These findings not only demonstrated the applicability and limitations of SSVEPs recorded from freely behaving humans in realistic environments, but also provide useful methods and techniques for boosting the translation of the BCI technology from laboratory demonstrations to practical applications

    Data Analytics in Steady-State Visual Evoked Potential-based Brain-Computer Interface: A Review

    Get PDF
    Electroencephalograph (EEG) has been widely applied for brain-computer interface (BCI) which enables paralyzed people to directly communicate with and control of external devices, due to its portability, high temporal resolution, ease of use and low cost. Of various EEG paradigms, steady-state visual evoked potential (SSVEP)-based BCI system which uses multiple visual stimuli (such as LEDs or boxes on a computer screen) flickering at different frequencies has been widely explored in the past decades due to its fast communication rate and high signal-to-noise ratio. In this paper, we review the current research in SSVEP-based BCI, focusing on the data analytics that enables continuous, accurate detection of SSVEPs and thus high information transfer rate. The main technical challenges, including signal pre-processing, spectrum analysis, signal decomposition, spatial filtering in particular canonical correlation analysis and its variations, and classification techniques are described in this paper. Research challenges and opportunities in spontaneous brain activities, mental fatigue, transfer learning as well as hybrid BCI are also discussed

    Comparison of PSDA and CCA detection methods in a SSVEP-based BCI-system

    Get PDF
    Using steady-state visually evoked potential (SSVEP) in brain-computer interface (BCI) systems is the subject of a lot of research. One of the most popular and widely used detection method is using a power spectral density analysis (PSDA). Lately there have been some new methods emerging, one of them is using canonical correlation analysis (CCA) which seems to have some promising improvements and advantages compared to traditional SSVEP detection methods, like better signal-to-noise ratio (SNR), lower inter-subject variability and the possibility to use harmonic frequencies, i.e., a serie of frequencies which have the same fundamental frequency. In this research two different SSVEP detection methods, one using PSDA and one using CCA are compared. The results show that the CCA-based detection method performs significantly better than the PSDA-based detection method. The increase of performance can in particular be seen when using harmonic frequencies. While the PSDA-based detection method has difficulties detecting harmonic frequencies, the CCA-based detection method is able to detect harmonic frequencies

    P300, Steady State Visual Evoked Potentials, And Hybrid Paradigms For A Brain Computer Interface Speller

    Get PDF
    The goal of this research was to evaluate and compare two types of brain computer interface (BCI) systems, P300 and steady state visually evoked potentials (SSVEP), as spelling paradigms and combine them as a hybrid approach. There were pilot experiments performed for designing the parameters of the SSVEP spelling paradigm including peak detection for different range of frequencies, placement of LEDs, design of the SSVEP stimulus board, and window time for the SSVEP peak detection processing. The next experiment was to evaluate the SSVEP spelling paradigm. Six subjects participated in the task. The accuracy of each frequency and average accuracy for each subject were considered. The second experiment was designed to compare the performance and accuracy of SSVEP, P300, and the combination of both paradigms as a simultaneous task. Ten subjects were considered for performing this experiment. Overall the average accuracy of the SSVEP spelling paradigm was 80.00 % and higher than the P300 spelling paradigm average accuracy which was 72.50 %, and both of the spelling paradigms have better accuracy than the hybrid paradigm with the average accuracy of 64.39 %

    Asynchronous BCI control using high-frequency SSVEP

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Steady-State Visual Evoked Potential (SSVEP) is a visual cortical response evoked by repetitive stimuli with a light source flickering at frequencies above 4 Hz and could be classified into three ranges: low (up to 12 Hz), medium (12-30) and high frequency (> 30 Hz). SSVEP-based Brain-Computer Interfaces (BCI) are principally focused on the low and medium range of frequencies whereas there are only a few projects in the high-frequency range. However, they only evaluate the performance of different methods to extract SSVEP.</p> <p>Methods</p> <p>This research proposed a high-frequency SSVEP-based asynchronous BCI in order to control the navigation of a mobile object on the screen through a scenario and to reach its final destination. This could help impaired people to navigate a robotic wheelchair. There were three different scenarios with different difficulty levels (easy, medium and difficult). The signal processing method is based on Fourier transform and three EEG measurement channels.</p> <p>Results</p> <p>The research obtained accuracies ranging in classification from 65% to 100% with Information Transfer Rate varying from 9.4 to 45 bits/min.</p> <p>Conclusions</p> <p>Our proposed method allows all subjects participating in the study to control the mobile object and to reach a final target without prior training.</p

    Brain-CAVE Interface Based on Steady-State Visual Evoked Potential

    Get PDF

    Usability of Transient VEPs in BCIs

    Get PDF

    A gaze independent brain-computer interface based on visual stimulation through closed eyelids

    Get PDF
    A classical brain-computer interface (BCI) based on visual event-related potentials (ERPs) is of limited application value for paralyzed patients with severe oculomotor impairments. In this study, we introduce a novel gaze independent BCI paradigm that can be potentially used for such end-users because visual stimuli are administered on closed eyelids. The paradigm involved verbally presented questions with 3 possible answers. Online BCI experiments were conducted with twelve healthy subjects, where they selected one option by attending to one of three different visual stimuli. It was confirmed that typical cognitive ERPs can be evidently modulated by the attention of a target stimulus in eyes-closed and gaze independent condition and further classified with high accuracy during online operation (74.58% ± 17.85 s.d.; chance level 33.33%), demonstrating the effectiveness of the proposed novel visual ERP paradigm. Also, stimulus-specific eye movements observed during stimulation were verified as reflex responses to light stimuli and they did not contribute to classification. To the best of our knowledge, this study is the first to show the possibility of using a gaze independent visual ERP paradigm in an eyes-closed condition, thereby providing another communication option for severely locked-in patients suffering from complex ocular dysfunctions.BMBF, 01GQ0850, Bernstein Fokus Neurotechnologie - Nichtinvasive Neurotechnologie für Mensch-Maschine InteraktionBMBF, 16SV5839, Maschinelles Lernen zur Optimierung der Kommunikation schwerstgelähmter Patienten per BC
    corecore