34 research outputs found

    POLYMERIC IMPULSIVE ACTUATION MECHANISMS: DEVELOPMENT, CHARACTERIZATION, AND MODELING

    Get PDF
    Recent advances in the field of biomedical and life-sciences are increasingly demanding more life-like actuation with higher degrees of freedom in motion at small scales. Many researchers have developed various solutions to satisfy these emerging requirements. In many cases, new solutions are made possible with the development of novel polymeric actuators. Advances in polymeric actuation not only addressed problems concerning low degree of freedom in motion, large system size, and bio-incompatibility associated with conventional actuators, but also led to the discovery of novel applications, which were previously unattainable with conventional engineered systems. This dissertation focuses on developing novel actuation mechanisms for soft polymeric gel systems with easily adjustable mechanochemical properties and applicability to various environmental conditions. Inspired by stunning examples in nature which exhibit extremely fast motion in a repeatable manner, termed impulsive motion, we have developed polymeric gel actuators applicable for small-scale, self-contained impulsive systems. In particular, we focused on the effect of geometry and the mechanics of surface-mediated stresses on the dynamic shape-change of polymer gel actuators. We found new opportunities from observation of transient deformations which occur during swelling, or deswelling, of asymmetric gels. We described the development of time-dependent three-dimensional deformation mechanism (4D fabrication) by the utilization of transient inhomogeneous swelling state of the asymmetric polymer gel. We discussed the mechanism and the application of the new deformations mechanism for the development of a novel functionality: chemical gradient sensor. In addition, we developed a high-rate and large-strain reversible actuation mechanism for sub-micrometer scale polymeric gel actuators by utilizing balanced effects of two surface-mediated phenomena, surface diffusion and interfacial-tension, and elasticity of soft and small-scale hydrogels. These new findings were harnessed for developing autonomously controlled power amplified polymeric gel devices. Utilizing deswelling induced transient deformation of gel, we developed design principles for generating meta-stable structures and inducing self-regulating transition forces for repeated snap-through buckling transition of polymeric gel devices. In parallel, we deconvoluted the effect of material properties and geometry on dynamic deformations by establishing simulation models and conducting analyses on the performances of actual synthetic systems. The systematic approach will serve to broaden the application spectrum and manufacturing possibilities of polymeric actuator systems

    A microgripper for single cell manipulation

    Get PDF
    This thesis presents the development of an electrothermally actuated microgripper for the manipulation of cells and other biological particles. The microgripper has been fabricated using a combination of surface and bulk micromachining techniques in a three mask process. All of the fabrication details have been chosen to enable a tri-layer, polymer (SU8) - metal (Au) - polymer (SU8), membrane to be released from the substrate stress free and without the need for sacrificial layers. An actuator design, which completely eliminates the parasitic resistance of the cold arm, is presented. When compared to standard U-shaped actuators, it improves the thermal efficiency threefold. This enables larger displacements at lower voltages and temperatures. The microgripper is demonstrated in three different configurations: normally open mode, normally closed mode, and normally open/closed mode. It has-been modelled using two coupled analytical models - electrothermal and thermomechanical - which have been custom developed for this application. Unlike previously reported models, the electrothermal model presented here includes the heat exchange between hot and cold arms of the actuators that are separated by a small air gap. A detailed electrothermomechanical characterisation of selected devices has permitted the validation of the models (also performed using finite element analysis) and the assessment of device performance. The device testing includes electrical, deflection, and temperature measurements using infrared (IR) thermography, its use in polymeric actuators reported here for the first time. Successful manipulation experiments have been conducted in both air and liquid environments. Manipulation of live cells (mice oocytes) in a standard biomanipulation station has validated the microgripper as a complementary and unique tool for the single cell experiments that are to be conducted by future generations of biologists in the areas of human reproduction and stem cell research

    Electronically integrated microcatheters based on self-assembling polymer films

    Get PDF
    Existing electronically integrated catheters rely on the manual assembly of separate components to integrate sensing and actuation capabilities. This strongly impedes their miniaturization and further integration. Here, we report an electronically integrated self-assembled microcatheter. Electronic components for sensing and actuation are embedded into the catheter wall through the self-assembly of photolithographically processed polymer thin films. With a diameter of only about 0.1 mm, the catheter integrates actuated digits for manipulation and a magnetic sensor for navigation and is capable of targeted delivery of liquids. Fundamental functionalities are demonstrated and evaluated with artificial model environments and ex vivo tissue. Using the integrated magnetic sensor, we develop a strategy for the magnetic tracking of medical tools that facilitates basic navigation with a high resolution below 0.1 mm. These highly flexible and microsized integrated catheters might expand the boundary of minimally invasive surgery and lead to new biomedical applications. Copyright © 2021 The Authors, some rights reserved

    Design and fabrication of a multipurpose compliant nanopositioning architecture

    Get PDF
    Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2013.This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.Cataloged from student-submitted PDF version of thesis.Includes bibliographical references (p. 227-241).This research focused on generating the knowledge required to design and fabricate a high-speed application flexible, low average cost multipurpose compliant nanopositioner architecture with high performance integrated sensing. Customized nanopositioner designs can be created in ~~1 week, for 30x increase in sensing dynamic range over comparable state-of-the-art compliant nanopositioners. These improvements will remove one of the main hurdles to practical non-IC nanomanufacturing, which could enable advances in a range of fields including personalized medication, computing and data storage, and energy generation/storage through the manufacture of metamaterials. Advances were made in two avenues: flexibility and affordability. The fundamental advance in flexibility is the use of a new approach to modeling the nanopositioner and sensors as combined mechanical/electronic systems. This enabled the discovery of the operational regimes and design rules needed to maximize performance, making it possible to rapidly redesign nanopositioner architecture for varying functional requirements such as range, resolution and force. The fundamental advance to increase affordability is the invention of Non-Lithographically-Based Microfabrication (NLBM), a hybrid macro-/micro-fabrication process chain that can produce MEMS with integrated sensing in a flexible manner, at small volumes and with low per-device costs. This will allow for low-cost customizable nanopositioning architectures with integrated position sensing to be created for a range of micro-/nano- manufacturing and metrology applications. A Hexflex 6DOF nanopositioner with titanium flexures and integrated siliconpiezoresistive sensing was fabricated using NLBM. This device was designed with a metal mechanical structure in order to improve its robustness for general handling and operation. Single crystalline silicon piezoresistors were patterned from bulk silicon wafers and transferred to the mechanical structure via thin-film patterning and transfer. This work demonstrates that it is now feasible to design and create a customized positioner for each nanomanufacturing/metrology application. The Hexflex architecture can be significantly varied to adjust range, resolution, force scale, stiffness, and DOF all as needed. The NLBM process was shown to enable alignment of device components on the scale of 10's of microns. 150ÎĽm piezoresistor arm widths were demonstrated, with suggestions made for how to reach the expected lower bound of 25[mu]m. Flexures of 150[mu]m and 600[mu]m were demonstrated on 4 the mechanical structure, with a lower bound of ~~50[mu]m expected for the process. Electrical traces of 800[mu]m width were used to ensure low resistance, with a lower bound of ~~100[mu]m expected for the process. The integrated piezoresistive sensing was designed to have a gage factor of about 125, but was reduced to about 70 due to lower substrate temperatures during soldering, as predicted by design theory. The sensors were measured to have a full noise dynamic range of about 59dB over a 10kHz sensor bandwidth, limited by the Schottky barrier noise. Several simple methods are suggested for boosting the performance to ~~135dB over a 10kHz sensor bandwidth, about a <1AĚŠ resolution over the 200[mu]m range of the case study device. This sensor performance is generally in excess of presently available kHz-bandwidth analog-to-digital converters.by Robert M. Panas.Ph.D
    corecore