6 research outputs found

    Advances in Solid State Circuit Technologies

    Get PDF
    This book brings together contributions from experts in the fields to describe the current status of important topics in solid-state circuit technologies. It consists of 20 chapters which are grouped under the following categories: general information, circuits and devices, materials, and characterization techniques. These chapters have been written by renowned experts in the respective fields making this book valuable to the integrated circuits and materials science communities. It is intended for a diverse readership including electrical engineers and material scientists in the industry and academic institutions. Readers will be able to familiarize themselves with the latest technologies in the various fields

    Neurostimulateur hautement intégré et nouvelle stratégie de stimulation pour améliorer la miction chez les paraplégiques

    Get PDF
    RÉSUMÉ Une lésion de la moelle épinière est un problème dévastateur médicalement et socialement. Pour la population des États-Unis seulement, il y a près de 10 000 nouveaux cas chaque année. A cause des nombreux types de lésions possibles, divers degrés de dysfonctionnement du bas appareil urinaire peuvent en découler. Une lésion est dite complète lors d’une perte totale des fonctions sensorielles et motrices volontaires en dessous du niveau de la lésion. Une lésion incomplète implique que certaines activités sensorielles et/ou motrices soient encore présentes. Si la lésion se produit au dessus du cône médullaire, la vessie développera une hyperréflexie qui se manifeste par des contractions réflexes non-inhibées. Ces contractions peuvent être accompagnées d’une augmentation de l’activité du sphincter externe. Par conséquent, cela mène à un état d’obstruction fonctionnelle de la vessie, qui induit une forte pression intravésicale à chacune des contractions réflexes et qui peut potentiellement endommager le haut appareil urinaire. Dans ce contexte, la neurostimulation est l'une des techniques les plus prometteuses pour la réhabilitation de la vessie chez les patients ayant subi une lésion de la moelle épinière. Le seul neurostimulateur implantable commercialisé, ciblant l'amélioration de la miction et ayant obtenu des résultats satisfaisants, nécessite une rhizotomie (section de certains nerfs) afin de réduire la dyssynergie entre la vessie et le sphincter. Cependant, la rhizotomie est irréversible et peut abolir les réflexes sexuels, de défécation ainsi que les sensations sacrales si encore présents dans le cas de lésions incomplètes. Afin d'éviter la rhizotomie, nous proposons une nouvelle stratégie de stimulation multi-site appliquée aux racines sacrées, et basée sur le blocage de la conduction des nerfs à l'aide d'une stimulation à haute fréquence comme alternative à la rhizotomie. Cette approche permettrait une meilleure miction en augmentant sélectivement la contraction de la vessie et en diminuant la dyssynergie. Huit expériences en phase aigüe ont étés menées sur des chiens pour vérifier la réponse de la vessie et du sphincter urétral externe à la stratégie de stimulation proposée. Le blocage à haute-fréquence (1 kHz) combiné à la stimulation basse-fréquence (30 Hz), a augmenté la différence de pression intra-vésicale/intra-urétrale moyenne jusqu'à 53 cmH2O et a réduit la pression intra-urétrale moyenne jusqu'à hauteur de 86 % relativement au niveau de référence. Dans l’objectif de tester la stratégie de neurostimulation proposée avec des expériences animales en phase chronique, un dispositif de neurostimulation implantable est requis. Un prototype discret implémentant cette stratégie de stimulation a été réalisé en utilisant uniquement des composants discrets disponibles commercialement. Ce prototype est capable de générer des impulsions à une fréquence aussi basse que 18 Hz tout en générant simultanément une forme d’onde alternative à une fréquence aussi haute que 8.6 kHz, et ce sur de multiples canaux. Lorsque tous les étages de stimulation et leurs différentes sorties sont activés avec des fréquences d’impulsions (2 mA, 217 μs) et de sinusoïdes de 30 Hz et 1 kHz respectivement, la consommation de puissance totale est autour de 4.5 mA (rms). Avec 50 mW de puissance inductive disponible par exemple et 4.5 mA de consommation de courant, le régulateur haute-tension peut être réglé à 10 V permettant ainsi une stimulation de 2 mA avec une impédance nerf-électrode de 4.4 kΩ. Le nombre effectif de sorties activées et le maximum réalisable des paramètres de stimulation sont limités par l’énergie disponible fournie par le lien inductif et l’impédance des interfaces nerf-électrode. Cependant, une plus grande intégration du neurostimulateur devient de plus en plus nécessaire à des fins de miniaturisation, de réduction de consommation de puissance, et d’augmentation du nombre de canaux de stimulation. Comme première étape vers une intégration totale, nous présentons la conception d’un neurostimulateur hautement intégré et qui peut être assemblé sur un circuit imprimé de 21 mm de diamètre. Le prototype est basé sur trois circuits intégrés, dédiés et fabriqués en technologie CMOS haute-tension, ainsi qu’un FPGA miniature à faible puissance et disponible commercialement. En utilisant une approche basée sur un abaisseur de tension, où la tension induite est laissée libre jusqu’à 20 V, l’étage d’entrée de récupération de puissance inductive et de données est totalement intégré.----------ABSTRACT Spinal cord injury (SCI) is a devastating condition medically and socially. For the population of USA only, the incidence is around 10 000 new cases per year. SCI leads to different degrees of dysfunction of the lower urinary tract due to a large variety of possible lesions. With a complete lesion, there is a complete loss of sensory and motor control below the level of lesion. An incomplete lesion implies that some sensory and/or motor activity is still present. Most patients with suprasacral SCI suffer from detrusor over-activity (DO) and detrusor sphincter dyssynergia (DSD). DSD leads to high intravesical pressure, high residual urine, urinary tract infection, and deterioration of the upper urinary tract. In this context, neurostimulation is one of the most promising techniques for bladder rehabilitation in SCI patients. The only commercialized implantable neurostimulator aiming for improved micturition and having obtained satisfactory results requires rhizotomy to reduce DSD. However, rhizotomy is irreversible and may abolish sexual and defecation reflexes as well as sacral sensations, if still present in case of incomplete SCI. In order to avoid rhizotomy, we propose a new multisite stimulation strategy applied to sacral roots, and based on nerve conduction blockade using high-frequency stimulation as an alternative to rhizotomy. This approach would allow a better micturition by increasing bladder contraction selectively and decreasing dyssynergia. Eight acute dog experiments were carried out to verify the bladder and the external urethral sphincter responses to the proposed stimulation strategy. High-frequency blockade (1 kHz) combined with low-frequency stimulation (30 Hz) increased the average intravesical-intraurethral pressure difference up to 53 cmH2O and reduced the average intraurethral pressure with respect to baseline by up to 86 %. To test the proposed neurostimulation strategy during chronic animal experiments, an implantable neurostimulateur is required. A discrete prototype implementing the proposed stimulation strategy has been designed using commercially available discrete components. This prototype is capable of generating a low frequency pulse waveform as low as 18 Hz with a simultaneous high frequency alternating waveform as high as 8.6 kHz, and that over different and multiple channels

    Study and design of topologies and components for high power density DC-DC converters

    Get PDF
    Size reduction of low power electronic DC–DC converters is a topic of major interest for power electronics which requires the study and design of circuits and components working under redefined requirements. For this purpose, novel circuital topologies provide advantages in terms of power density increment, especially where a single chip design is feasible. These concepts have been applied to design and implement an integrated high step-down multiphase buck converter and to study the miniaturization of a stackable fiflyback architecture. Particular attention has been dedicated to power inductors, focusing on the modeling and measurement of magnetic materials’ hysteresis and core losses

    ENABLING HARDWARE TECHNOLOGIES FOR AUTONOMY IN TINY ROBOTS: CONTROL, INTEGRATION, ACTUATION

    Get PDF
    The last two decades have seen many exciting examples of tiny robots from a few cm3 to less than one cm3. Although individually limited, a large group of these robots has the potential to work cooperatively and accomplish complex tasks. Two examples from nature that exhibit this type of cooperation are ant and bee colonies. They have the potential to assist in applications like search and rescue, military scouting, infrastructure and equipment monitoring, nano-manufacture, and possibly medicine. Most of these applications require the high level of autonomy that has been demonstrated by large robotic platforms, such as the iRobot and Honda ASIMO. However, when robot size shrinks down, current approaches to achieve the necessary functions are no longer valid. This work focused on challenges associated with the electronics and fabrication. We addressed three major technical hurdles inherent to current approaches: 1) difficulty of compact integration; 2) need for real-time and power-efficient computations; 3) unavailability of commercial tiny actuators and motion mechanisms. The aim of this work was to provide enabling hardware technologies to achieve autonomy in tiny robots. We proposed a decentralized application-specific integrated circuit (ASIC) where each component is responsible for its own operation and autonomy to the greatest extent possible. The ASIC consists of electronics modules for the fundamental functions required to fulfill the desired autonomy: actuation, control, power supply, and sensing. The actuators and mechanisms could potentially be post-fabricated on the ASIC directly. This design makes for a modular architecture. The following components were shown to work in physical implementations or simulations: 1) a tunable motion controller for ultralow frequency actuation; 2) a nonvolatile memory and programming circuit to achieve automatic and one-time programming; 3) a high-voltage circuit with the highest reported breakdown voltage in standard 0.5 ÎĽm CMOS; 4) thermal actuators fabricated using CMOS compatible process; 5) a low-power mixed-signal computational architecture for robotic dynamics simulator; 6) a frequency-boost technique to achieve low jitter in ring oscillators. These contributions will be generally enabling for other systems with strict size and power constraints such as wireless sensor nodes
    corecore