25,399 research outputs found

    Sensor Sleeve: Sensing Affective Gestures

    Full text link
    We describe the use of textile sensors mounted in a garment sleeve to detect affective gestures. The `Sensor Sleeve' is part of a larger project to explore the role of affect in communications. Pressure activated, capacitive and elasto-resistive sensors are investigated and their relative merits reported on. An implemented application is outlined in which a cellphone receives messages derived from the sleeve's sensors using a Bluetooth interface, and relays the signals as text messages to the user's nominated partner

    Using Noninvasive Brain Measurement to Explore the Psychological Effects of Computer Malfunctions on Users during Human-Computer Interactions

    Full text link
    In today’s technologically driven world, there is a need to better understand the ways that common computer malfunctions affect computer users. These malfunctions may have measurable influences on computer user’s cognitive, emotional, and behavioral responses. An experiment was conducted where participants conducted a series of web search tasks while wearing functional nearinfrared spectroscopy (fNIRS) and galvanic skin response sensors. Two computer malfunctions were introduced during the sessions which had the potential to influence correlates of user trust and suspicion. Surveys were given after each session to measure user’s perceived emotional state, cognitive load, and perceived trust. Results suggest that fNIRS can be used to measure the different cognitive and emotional responses associated with computer malfunctions. These cognitive and emotional changes were correlated with users’ self-report levels of suspicion and trust, and they in turn suggest future work that further explores the capability of fNIRS for the measurement of user experience during human-computer interactions

    System Monitoring of the Emotional State of Students in High School

    Get PDF
    The resistance of skin is measured by means of special elastic bracelet which is connected to fingers and then is transmitted to measuring device. The control is based on the method of measurement impedance of students. After this, the detected signal from output of the measuring device is sent to PC. Special software treats this information and diagnoses the students. This system is basically able to: to determine the emotional status of students; to create daily archive database for each student; to make analysis accordingly to this archive

    An International Urogynecological Association (IUGA)/International Continence Society (ICS) joint report on the terminology for the conservative and nonpharmacological management of female pelvic floor dysfunction

    Get PDF
    There has been an increasing need for the terminology on the conservative management of female pelvic floor dysfunction to be collated in a clinically based consensus report.This Report combines the input of members and elected nominees of the Standardization and Terminology Committees of two International Organizations, the International Urogynecological Association (IUGA) and the International Continence Society (ICS), assisted at intervals by many external referees. An extensive process of nine rounds of internal and external review was developed to exhaustively examine each definition, with decision-making by collective opinion (consensus). Before opening up for comments on the webpages of ICS and IUGA, five experts from physiotherapy, neurology, urology, urogynecology, and nursing were invited to comment on the paper.A Terminology Report on the conservative management of female pelvic floor dysfunction, encompassing over 200 separate definitions, has been developed. It is clinically based, with the most common symptoms, signs, assessments, diagnoses, and treatments defined. Clarity and ease of use have been key aims to make it interpretable by practitioners and trainees in all the different specialty groups involved in female pelvic floor dysfunction. Ongoing review is not only anticipated, but will be required to keep the document updated and as widely acceptable as possible.A consensus-based terminology report for the conservative management of female pelvic floor dysfunction has been produced, aimed at being a significant aid to clinical practice and a stimulus for research

    MsWH: A multi-sensory hardware platform for capturing and analyzing physiological emotional signals

    Get PDF
    This paper presents a new physiological signal acquisition multi-sensory platform for emotion detection: Multi-sensor Wearable Headband (MsWH). The system is capable of recording and analyzing five different physiological signals: skin temperature, blood oxygen saturation, heart rate (and its variation), movement/position of the user (more specifically of his/her head) and electrodermal activity/bioimpedance. The measurement system is complemented by a porthole camera positioned in such a way that the viewing area remains constant. Thus, the user''s face will remain centered regardless of its position and movement, increasing the accuracy of facial expression recognition algorithms. This work specifies the technical characteristics of the developed device, paying special attention to both the hardware used (sensors, conditioning, microprocessors, connections) and the software, which is optimized for accurate and massive data acquisition. Although the information can be partially processed inside the device itself, the system is capable of sending information via Wi-Fi, with a very high data transfer rate, in case external processing is required. The most important features of the developed platform have been compared with those of a proven wearable device, namely the Empatica E4 wristband, in those measurements in which this is possible

    Development of Galvanic Skin Response Sensor System to Measure Mental Stress

    Get PDF
    Stress is a very normal reaction when a person is feel threaten or upset in some way. Generally, stress happen when a person ability is not able to meet with the situational demands. It can be either positive or negative. Stress can give a person to have high concentration to face certain circumstances as well as better reaction to handle difficult situation. On the other side, it can also cause sickness to a person if one is suffer from overstress. A person will have health issues like the risk of depression and neurological disorders like stroke if mental stress level is too high. Thus, a device is necessary to measure the stress level so that the stress level can be regulate before it is out of control. Although there are several of methods in the market that are able to measure the stress level, but there are all expensive and complicated. Thus, this project will be focusing on developing a Galvanic Skin Response Sensor that are able to measure stress level based on the skin conductivity. GSR sensor is an economical tool to measure stress level with simpler analysis. Complete methodology and findings are shown as we go through the report

    New methodology to detect the effects of emotions on different biometrics in real time

    Get PDF
    Recently, some problems have appeared among medical workers during the diagnosis of some diseases due to human errors or the lack of sufficient information for the diagnosis. In medical diagnosis, doctors always resort to separating human emotions and their impact on vital parameters. In this paper, a methodology is presented to measure vital parameters more accurately while studying the effect of different human emotions on vital signs. Two designs were implemented based on the microcontroller and National Instruments (NI) myRIO. Measurements of four different vital parameters are measured and recorded in real time. At the same time, the effects of different emotions on those vital parameters are recorded and stored for use in analysis and early diagnosis. The results proved that the proposed methodology can contribute to the prediction and diagnosis of the initial symptoms of some diseases such as the seventh nerve and Parkinson’s disease. The two proposed designs are compared with the reference device (beurer) results. The design using NI myRIO achieved more accurate results and a response time of 1.4 seconds for real-time measurements compared to its counterpart based on microcontrollers, which qualifies it to work in intensive care units
    corecore