460 research outputs found

    Accurate quantum transport modelling and epitaxial structure design of high-speed and high-power In0.53Ga0.47As/AlAs double-barrier resonant tunnelling diodes for 300-GHz oscillator sources

    Get PDF
    Terahertz (THz) wave technology is envisioned as an appealing and conceivable solution in the context of several potential high-impact applications, including sixth generation (6G) and beyond consumer-oriented ultra-broadband multi-gigabit wireless data-links, as well as highresolution imaging, radar, and spectroscopy apparatuses employable in biomedicine, industrial processes, security/defence, and material science. Despite the technological challenges posed by the THz gap, recent scientific advancements suggest the practical viability of THz systems. However, the development of transmitters (Tx) and receivers (Rx) based on compact semiconductor devices operating at THz frequencies is urgently demanded to meet the performance requirements calling from emerging THz applications. Although several are the promising candidates, including high-speed III-V transistors and photo-diodes, resonant tunnelling diode (RTD) technology offers a compact and high performance option in many practical scenarios. However, the main weakness of the technology is currently represented by the low output power capability of RTD THz Tx, which is mainly caused by the underdeveloped and non-optimal device, as well as circuit, design implementation approaches. Indeed, indium phosphide (InP) RTD devices can nowadays deliver only up to around 1 mW of radio-frequency (RF) power at around 300 GHz. In the context of THz wireless data-links, this severely impacts the Tx performance, limiting communication distance and data transfer capabilities which, at the current time, are of the order of few tens of gigabit per second below around 1 m. However, recent research studies suggest that several milliwatt of output power are required to achieve bit-rate capabilities of several tens of gigabits per second and beyond, and to reach several metres of communication distance in common operating conditions. Currently, the shortterm target is set to 5−10 mW of output power at around 300 GHz carrier waves, which would allow bit-rates in excess of 100 Gb/s, as well as wireless communications well above 5 m distance, in first-stage short-range scenarios. In order to reach it, maximisation of the RTD highfrequency RF power capability is of utmost importance. Despite that, reliable epitaxial structure design approaches, as well as accurate physical-based numerical simulation tools, aimed at RF power maximisation in the 300 GHz-band are lacking at the current time. This work aims at proposing practical solutions to address the aforementioned issues. First, a physical-based simulation methodology was developed to accurately and reliably simulate the static current-voltage (IV ) characteristic of indium gallium arsenide/aluminium arsenide (In-GaAs/AlAs) double-barrier RTD devices. The approach relies on the non-equilibrium Green’s function (NEGF) formalism implemented in Silvaco Atlas technology computer-aided design (TCAD) simulation package, requires low computational budget, and allows to correctly model In0.53Ga0.47As/AlAs RTD devices, which are pseudomorphically-grown on lattice-matched to InP substrates, and are commonly employed in oscillators working at around 300 GHz. By selecting the appropriate physical models, and by retrieving the correct materials parameters, together with a suitable discretisation of the associated heterostructure spatial domain through finite-elements, it is shown, by comparing simulation data with experimental results, that the developed numerical approach can reliably compute several quantities of interest that characterise the DC IV curve negative differential resistance (NDR) region, including peak current, peak voltage, and voltage swing, all of which are key parameters in RTD oscillator design. The demonstrated simulation approach was then used to study the impact of epitaxial structure design parameters, including those characterising the double-barrier quantum well, as well as emitter and collector regions, on the electrical properties of the RTD device. In particular, a comprehensive simulation analysis was conducted, and the retrieved output trends discussed based on the heterostructure band diagram, transmission coefficient energy spectrum, charge distribution, and DC current-density voltage (JV) curve. General design guidelines aimed at enhancing the RTD device maximum RF power gain capability are then deduced and discussed. To validate the proposed epitaxial design approach, an In0.53Ga0.47As/AlAs double-barrier RTD epitaxial structure providing several milliwatt of RF power was designed by employing the developed simulation methodology, and experimentally-investigated through the microfabrication of RTD devices and subsequent high-frequency characterisation up to 110 GHz. The analysis, which included fabrication optimisation, reveals an expected RF power performance of up to around 5 mW and 10 mW at 300 GHz for 25 μm2 and 49 μm2-large RTD devices, respectively, which is up to five times higher compared to the current state-of-the-art. Finally, in order to prove the practical employability of the proposed RTDs in oscillator circuits realised employing low-cost photo-lithography, both coplanar waveguide and microstrip inductive stubs are designed through a full three-dimensional electromagnetic simulation analysis. In summary, this work makes and important contribution to the rapidly evolving field of THz RTD technology, and demonstrates the practical feasibility of 300-GHz high-power RTD devices realisation, which will underpin the future development of Tx systems capable of the power levels required in the forthcoming THz applications

    Deciphering Radio Emission from Solar Coronal Mass Ejections using High-fidelity Spectropolarimetric Radio Imaging

    Full text link
    Coronal mass ejections (CMEs) are large-scale expulsions of plasma and magnetic fields from the Sun into the heliosphere and are the most important driver of space weather. The geo-effectiveness of a CME is primarily determined by its magnetic field strength and topology. Measurement of CME magnetic fields, both in the corona and heliosphere, is essential for improving space weather forecasting. Observations at radio wavelengths can provide several remote measurement tools for estimating both strength and topology of the CME magnetic fields. Among them, gyrosynchrotron (GS) emission produced by mildly-relativistic electrons trapped in CME magnetic fields is one of the promising methods to estimate magnetic field strength of CMEs at lower and middle coronal heights. However, GS emissions from some parts of the CME are much fainter than the quiet Sun emission and require high dynamic range (DR) imaging for their detection. This thesis presents a state-of-the-art calibration and imaging algorithm capable of routinely producing high DR spectropolarimetric snapshot solar radio images using data from a new technology radio telescope, the Murchison Widefield Array. This allows us to detect much fainter GS emissions from CME plasma at much higher coronal heights. For the first time, robust circular polarization measurements have been jointly used with total intensity measurements to constrain the GS model parameters, which has significantly improved the robustness of the estimated GS model parameters. A piece of observational evidence is also found that routinely used homogeneous and isotropic GS models may not always be sufficient to model the observations. In the future, with upcoming sensitive telescopes and physics-based forward models, it should be possible to relax some of these assumptions and make this method more robust for estimating CME plasma parameters at coronal heights.Comment: 297 pages, 100 figures, 9 tables. Submitted at Tata Institute of Fundamental Research, Mumbai, India, Ph.D Thesi

    Autonomous Radar-based Gait Monitoring System

    Get PDF
    Features related to gait are fundamental metrics of human motion [1]. Human gait has been shown to be a valuable and feasible clinical marker to determine the risk of physical and mental functional decline [2], [3]. Technologies that detect changes in people’s gait patterns, especially older adults, could support the detection, evaluation, and monitoring of parameters related to changes in mobility, cognition, and frailty. Gait assessment has the potential to be leveraged as a clinical measurement as it is not limited to a specific health care discipline and is a consistent and sensitive test [4]. A wireless technology that uses electromagnetic waves (i.e., radar) to continually measure gait parameters at home or in a hospital without a clinician’s participation has been proposed as a suitable solution [3], [5]. This approach is based on the interaction between electromagnetic waves with humans and how their bodies impact the surrounding and scattered wireless signals. Since this approach uses wireless waves, people do not need to wear or carry a device on their bodies. Additionally, an electromagnetic wave wireless sensor has no privacy issues because there is no video-based camera. This thesis presents the design and testing of a radar-based contactless system that can monitor people’s gait patterns and recognize their activities in a range of indoor environments frequently and accurately. In this thesis, the use of commercially available radars for gait monitoring is investigated, which offers opportunities to implement unobtrusive and contactless gait monitoring and activity recognition. A novel fast and easy-to-implement gait extraction algorithm that enables an individual’s spatiotemporal gait parameter extraction at each gait cycle using a single FMCW (Frequency Modulated Continuous Wave) radar is proposed. The proposed system detects changes in gait that may be the signs of changes in mobility, cognition, and frailty, particularly for older adults in individual’s homes, retirement homes and long-term care facilities retirement homes. One of the straightforward applications for gait monitoring using radars is in corridors and hallways, which are commonly available in most residential homes, retirement, and long-term care homes. However, walls in the hallway have a strong “clutter” impact, creating multipath due to the wide beam of commercially available radar antennas. The multipath reflections could result in an inaccurate gait measurement because gait extraction algorithms employ the assumption that the maximum reflected signals come from the torso of the walking person (rather than indirect reflections or multipath) [6]. To address the challenges of hallway gait monitoring, two approaches were used: (1) a novel signal processing method and (2) modifying the radar antenna using a hyperbolic lens. For the first approach, a novel algorithm based on radar signal processing, unsupervised learning, and a subject detection, association and tracking method is proposed. This proposed algorithm could be paired with any type of multiple-input multiple-output (MIMO) or single-input multiple-output (SIMO) FMCW radar to capture human gait in a highly cluttered environment without needing radar antenna alteration. The algorithm functionality was validated by capturing spatiotemporal gait values (e.g., speed, step points, step time, step length, and step count) of people walking in a hallway. The preliminary results demonstrate the promising potential of the algorithm to accurately monitor gait in hallways, which increases opportunities for its applications in institutional and home environments. For the second approach, an in-package hyperbola-based lens antenna was designed that can be integrated with a radar module package empowered by the fast and easy-to-implement gait extraction method. The system functionality was successfully validated by capturing the spatiotemporal gait values of people walking in a hallway filled with metallic cabinets. The results achieved in this work pave the way to explore the use of stand-alone radar-based sensors in long hallways for day-to-day long-term monitoring of gait parameters of older adults or other populations. The possibility of the coexistence of multiple walking subjects is high, especially in long-term care facilities where other people, including older adults, might need assistance during walking. GaitRite and wearables are not able to assess multiple people’s gait at the same time using only one device [7], [8]. In this thesis, a novel radar-based algorithm is proposed that is capable of tracking multiple people or extracting walking speed of a participant with the coexistence of other people. To address the problem of tracking and monitoring multiple walking people in a cluttered environment, a novel iterative framework based on unsupervised learning and advanced signal processing was developed and tested to analyze the reflected radio signals and extract walking movements and trajectories in a hallway environment. Advanced algorithms were developed to remove multipath effects or ghosts created due to the interaction between walking subjects and stationary objects, to identify and separate reflected signals of two participants walking at a close distance, and to track multiple subjects over time. This method allows the extraction of walking speed in multiple closely-spaced subjects simultaneously, which is distinct from previous approaches where the speed of only one subject was obtained. The proposed multiple-people gait monitoring was assessed with 22 participants who participated in a bedrest (BR) study conducted at McGill University Health Centre (MUHC). The system functionality also was assessed for in-home applications. In this regard, a cloud-based system is proposed for non-contact, real-time recognition and monitoring of physical activities and walking periods within a domestic environment. The proposed system employs standalone Internet of Things (IoT)-based millimeter wave radar devices and deep learning models to enable autonomous, free-living activity recognition and gait analysis. Range-Doppler maps generated from a dataset of real-life in-home activities are used to train deep learning models. The performance of several deep learning models was evaluated based on accuracy and prediction time, with the gated recurrent network (GRU) model selected for real-time deployment due to its balance of speed and accuracy compared to 2D Convolutional Neural Network Long Short-Term Memory (2D-CNNLSTM) and Long Short-Term Memory (LSTM) models. In addition to recognizing and differentiating various activities and walking periods, the system also records the subject’s activity level over time, washroom use frequency, sleep/sedentary/active/out-of-home durations, current state, and gait parameters. Importantly, the system maintains privacy by not requiring the subject to wear or carry any additional devices

    SuperCDMS HVeV Run 2 Low-Mass Dark Matter Search, Highly Multiplexed Phonon-Mediated Particle Detector with Kinetic Inductance Detector, and the Blackbody Radiation in Cryogenic Experiments

    Get PDF
    There is ample evidence of dark matter (DM), a phenomenon responsible for ≈ 85% of the matter content of the Universe that cannot be explained by the Standard Model (SM). One of the most compelling hypotheses is that DM consists of beyond-SM particle(s) that are nonluminous and nonbaryonic. So far, numerous efforts have been made to search for particle DM, and yet none has yielded an unambiguous observation of DM particles. We present in Chapter 2 the SuperCDMS HVeV Run 2 experiment, where we search for DM in the mass ranges of 0.5--10⁴ MeV/c² for the electron-recoil DM and 1.2--50 eV/c² for the dark photon and the Axion-like particle (ALP). SuperCDMS utilizes cryogenic crystals as detectors to search for DM interaction with the crystal atoms. The interaction is detected in the form of recoil energy mediated by phonons. In the HVeV project, we look for electron recoil, where we enhance the signal by the Neganov-Trofimov-Luke effect under high-voltage biases. The technique enabled us to detect quantized e⁻h⁺ creation at a 3% ionization energy resolution. Our work is the first DM search analysis considering charge trapping and impact ionization effects for solid-state detectors. We report our results as upper limits for the assumed particle models as functions of DM mass. Our results exclude the DM-electron scattering cross section, the dark photon kinetic mixing parameter, and the ALP axioelectric coupling above 8.4 x 10⁻³⁴ cm², 3.3 x 10⁻¹⁴, and 1.0 x 10⁻⁹, respectively. Currently every SuperCDMS detector is equipped with a few phonon sensors based on the transition-edge sensor (TES) technology. In order to improve phonon-mediated particle detectors' background rejection performance, we are developing highly multiplexed detectors utilizing kinetic inductance detectors (KIDs) as phonon sensors. This work is detailed in chapter 3 and chapter 4. We have improved our previous KID and readout line designs, which enabled us to produce our first ø3" detector with 80 phonon sensors. The detector yielded a frequency placement accuracy of 0.07%, indicating our capability of implementing hundreds of phonon sensors in a typical SuperCDMS-style detector. We detail our fabrication technique for simultaneously employing Al and Nb for the KID circuit. We explain our signal model that includes extracting the RF signal, calibrating the RF signal into pair-breaking energy, and then the pulse detection. We summarize our noise condition and develop models for different noise sources. We combine the signal and the noise models to be an energy resolution model for KID-based phonon-mediated detectors. From this model, we propose strategies to further improve future detectors' energy resolution and introduce our ongoing implementations. Blackbody (BB) radiation is one of the plausible background sources responsible for the low-energy background currently preventing low-threshold DM experiments to search for lower DM mass ranges. In Chapter 5, we present our study for such background for cryogenic experiments. We have developed physical models and, based on the models, simulation tools for BB radiation propagation as photons or waves. We have also developed a theoretical model for BB photons' interaction with semiconductor impurities, which is one of the possible channels for generating the leakage current background in SuperCDMS-style detectors. We have planned for an experiment to calibrate our simulation and leakage current generation model. For the experiment, we have developed a specialized ``mesh TES'' photon detector inspired by cosmic microwave background experiments. We present its sensitivity model, the radiation source developed for the calibration, and the general plan of the experiment.</p

    Spin Detection, Amplification, and Microwave Squeezing with Kinetic Inductance Parametric Amplifiers

    Full text link
    Superconducting parametric amplifiers operating at microwave frequencies have become an essential component in circuit quantum electrodynamics experiments. They are used to amplify signals at the single-photon level, while adding only the minimum amount of noise required by quantum mechanics. To achieve gain, energy is transferred from a pump to the signal through a non-linear interaction. A common strategy to enhance this process is to place the non-linearity inside a high quality factor resonator, but so far, quantum limited amplifiers of this type have only been demonstrated from designs that utilize Josephson junctions. Here we demonstrate the Kinetic Inductance Parametric Amplifier (KIPA), a three-wave mixing resonant parametric amplifier that exploits the kinetic inductance intrinsic to thin films of disordered superconductors. We then utilize the KIPA for measurements of 209Bi spin ensembles in Si. First, we show that a KIPA can serve simultaneously as a high quality factor resonator for pulsed electron spin resonance measurements and as a low-noise parametric amplifier. Using this dual-functionality, we enhance the signal to noise ratio of our measurements by more than a factor of seven and ultimately achieve a measurement sensitivity of 2.4 x 10^3 spins. Then we show that pushed to the high-gain limit, KIPAs can serve as a `click'-detector for microwave wave packets by utilizing a hysteretic transition to a self-oscillating state. We calibrate the detector's sensitivity to be 3.7 zJ and then apply it to measurements of electron spin resonance. Finally, we demonstrate the suitability of the KIPA for generating squeezed vacuum states. Using a cryogenic noise source, we first confirm the KIPAs in our experiment to be quantum limited amplifiers. Then, using two KIPAs arranged in series, we make direct measurements of vacuum noise squeezing, where we generate itinerant squeezed states with minimum uncertainty more than 7 dB below the standard quantum limit. High quality factor resonators have also recently been used to achieve strong coupling between the spins of single electrons in gate-defined quantum dots and microwave photons. We present our efforts to achieve the equivalent goal for the 31P flip-flop qubit. In doing so, we confirm previous predictions that the superconducting material MoRe would produce magnetic field-resilient resonators and demonstrate that it has kinetic inductance equivalent to the popular material NbTiN

    Nanoscale Single-Photon Detectors

    Get PDF
    Photodetectors are universal sensors employed in telecommunication technologies, telescopes for astronomy, optical imaging, environmental monitoring, and spectroscopy. The Avalanche Photodiode (APD) is widely used in these areas due to its CMOS integration and high sensitivities in linear operation. Demand for higher sensitivity detectors has steadily increased as technology has improved, with many fields requiring low light and single photon detection levels, such as quantum communications. APDs can achieve single photon sensitivities. However they require very high bias (100 -300 V) to operate. In lab environments and special use equipment superconducting single photon nanowire detectors have been employed for their high detection efficiencies, though their cryogenic cooling makes them bulky and inconvenient. A new CMOS compatible detector based on the cycling excitation process (CEP) has demonstrated improved performance from APDs with 30 dB of photocurrent gain and excess noise factors (ENF) of 2 at room temperature operations. Fabrication process flows are developed and employed to create CEP detectors that demonstrate a responsivity greater than 1 in linear operation at 14 V operating bias and gain equivalent to previous works in both DC and AC operation. Low light and single photon signals suffer disproportionately from optical losses, where losses from reflected light, unabsorbed light, and non-ideal absorption make up a significant proportion of detection events. Solar cell technology has developed several approaches to achieve high optical efficiencies, such as antireflection coatings, photonic crystals (PC) and plasmonics. PCs have high flexibility in their design parameters and are easily configurable to desired wavelengths, making them an appealing solution. In this work, we propose and simulate different photonic crystal (PC) structures to enhance the optical efficiency of CEP detectors and develop fabrication process flows to realise them

    7° Jornadas ITEE 2023

    Get PDF
    En esta publicación se reúnen los trabajos y resúmenes extendidos presentados en las VII Jornadas de Investigación, Transferencia, Extensión y Enseñanza (ITEE), de la Facultad de Ingeniería de la Universidad Nacional de La Plata, organizadas por la Secretaría de Investigación y Transferencia de dicha facultad, que tuvieron lugar entre el 25 y el 27 de abril de 2023.Facultad de Ingenierí

    Concepts in low-cost and flow NMR

    Get PDF

    Electronic and photonic integrated circuits for millimeter wave-over-fiber

    No full text
    corecore