1,064 research outputs found

    Evaluating a breast tumor monitoring vest with flexible UWB antennas and realistic phantoms:a proof-of-concept study

    Get PDF
    Abstract. The introduction provides an overview of the global significance of breast cancer as a health concern and the limitations of existing breast cancer screening methods. It introduces the concept of microwave-based breast cancer monitoring and highlights the promising findings from a previous research paper. The objective of the master thesis is presented, which is to develop and evaluate a self-monitoring vest equipped with UWB antennas and channel analysis to overcome the limitations of current screening methods and enable regular breast cancer monitoring from home. The "Background and Literature Review," provides a comprehensive overview of the relevant topics related to microwave techniques for breast cancer detection. It starts by discussing the anatomy of the female breast, highlighting the importance of understanding its structure for effective tumor detection. The section then delves into the microwave properties of the human breast, elucidating the interactions between microwaves and breast tissue. The basic principle of microwave channel analysis is explained, emphasizing its significance in detecting breast tumors. Furthermore, the advantages of microwave-based tumor detection methods are explored, showcasing their potential for improved breast cancer screening. Various microwave techniques used in breast cancer detection, including microwave tomography and radar-based UWB microwave imaging, are discussed, along with different self-monitoring vests integrated with UWB antennas. This section serves as a foundation for the subsequent chapters of the thesis, providing a comprehensive background and literature review to support the research and development of the practical self-monitoring vest for early detection of small-sized breast tumors. The "Preparation of Tissue Phantoms" section in the master’s thesis explores the comprehensive methodology for creating tissue phantoms that replicate the dielectric properties of various human tissues. While the section primarily focuses on fat tissue, it also acknowledges the existence of other phantom types. The outlined approach involves careful ingredient selection, formulation development, fabrication techniques, and stability evaluation for the creation of skin, muscle, fat, tumor, and gland tissue phantoms. By following these procedures, researchers can successfully produce tissue phantoms that closely mimic the properties of real human tissues. These phantoms serve as essential tools for investigating microwave-based applications in medical diagnostics and provide a reliable and versatile platform for further research in the field. The third section discusses the assembly of heterogeneous breast phantoms used for evaluating the performance of the tumor detection vest. The phantoms consisted of outer and inner molds, with the outer molds resembling the shape of a prone human breast. Two breast density types, representing very dense and less dense breasts, were used. For the dense breast phantoms, liquid fat material was solidified in the outer molds, and a glandular liquid was poured into the inner mold, with tumors inserted and covered with additional glandular liquid. For the less dense breast phantoms, fat liquid was solidified in the outer molds, and cylindrical glandular molds were inserted. A skin layer and muscle layer were added to complete the assembly, accurately simulating the composition and structure of a breast. This realistic breast phantom assembly allowed for accurate measurements and evaluation of the vest’s performance under different breast density conditions, contributing to breast imaging research and development. The "Monitoring Vest" section discusses the antennas used in the tumor detection vest and the design of two different vest versions. Antenna1 is a UWB monopole antenna with a flexible laminate substrate, while Antenna2 is a textile-based version of Antenna1. Antenna3 has a Kapton-based substrate and larger dimensions. The combination of these antennas ensures accurate tumor detection in various breast conditions. The section also highlights the measurement and comparison of the S11 parameter for the PCB antenna in free space and when placed on the skin, emphasizing the impact of the skin on antenna performance. The section concludes by describing the design of the vests, including the arrangement of pockets and the use of RF cables for connection. The careful design and implementation of the vests and antenna placement ensure accurate measurements and reliable performance evaluation. The results section of the study shows that the presence of tumors in breast tissue leads to a noticeable decrease in channel attenuation. The higher dielectric properties of tumors cause additional reflections and diffraction, affecting signal propagation within the breast. These changes in channel characteristics are influenced by factors such as tumor size, breast density, and antenna configuration. The study demonstrates the detectability of tumors and provides valuable insights for developing effective tumor detection systems in different breast tissue scenarios. In this master thesis, a prototype of a breast tumor monitoring vest utilizing UWB flexible antennas was developed and evaluated. The research demonstrated the effectiveness of the vest in detecting breast tumors, even as small as 1cm, by leveraging the distinct characteristics of radio channels among multiple on-body antennas embedded in the vest. Higher frequencies in the 7–8 GHz range showed improved resolution and contrast in relative permittivity, enhancing the accuracy of tumor detection. The development of tissue phantoms played a crucial role, enabling reliable experiments to mimic human tissues. Integration of advanced AI algorithms and 6G technology holds promise for enhancing diagnostic capabilities and revolutionizing healthcare. Overall, the breast tumor monitoring vest shows potential for widespread implementation in breast health checks, home monitoring, and wireless healthcare systems

    Microwave Imaging for Diagnostic Application

    Get PDF
    Imaging of the human body makes a significant contribution to the diagnosis and succeeding treatment of diseases. Among the numerous medical imaging methods, microwave imaging (MWI) is an attractive approach for medical applications due to its high potential to produce images of the human body safely with cost-efficiency. A wide range of studies and research has been done with the aim of using the microwave approach for medical applications. The focus of this research is developing MWI algorithms, which is the Huygens Principle (HP) based and to validate the capability of the proposed MWI algorithm to detect skin cancer and bone lesion through phantom measurements. The probability of the HP procedure for skin cancer detection has been investigated through design, and fabrication of a heterogeneous phantom simulating the human forearm having an inclusion mimicking a skin cancer. Ultrawideband (UWB) MWI methods are then applied to the phantom. The S21 parameter measurements are collected in an anechoic chamber environment and processed via HP technique. The tumour is successfully detected after applying appropriate artefact removal procedure. The ability to successfully apply HP to detect and locate a skin cancer type inclusion in a multilayer cylindrical phantom has been verified. The feasibility study of HP-based MWI procedure for bone lesion detection has also been investigated using a dedicated phantom. Validation has been completed through measurements inside the anechoic chamber in the frequency range of 1–3 GHz using one receiving and one transmitting antennas in free space. The identification of the lesion’s presence in different bone layers has been performed on images. The quantification of the obtained images has been performed by introducing parameters such as the resolution and signal-to-clutter ratio (S/C). The impact of different frequencies and bandwidths (in the 1–3 GHz range) in lesion detection has been investigated. The findings showed that the frequency range of 1.5–2.5 GHz offered the best resolution (1.1 cm) and S/C (2.22 on a linear scale). Subtraction between S21 obtained using two slightly displaced transmitting positions has been employed to remove the artefacts; the best artefact removal has been obtained when the spatial displacement was approximately of the same magnitude as the dimension of the lesion. Subsequently, a phantom validation of a low complexity MWI device (based on HP) operating in free space in the 1-6.5 GHz frequency band using two antennas in free space has been applied. Detection has been achieved in both bone fracture lesion and bone marrow lesion scenarios using superimposition of five doublet transmitting positions after applying the rotation subtraction method to remove artefact. A resolution of 5 mm and the S/C (3.35 in linear scale) are achieved which is clearly confirming the advantage of employing multiple transmitting positions on increased detection capability. The finding of this research verifies the dedicated MWI device as a simple, safe and without any X-ray radiation, portable, and low complexity method, which is capable of been successfully used for bone lesion detection. The outcomes of this thesis may pave the way for the construction of a dedicated bone imaging system that in future could be used as a safe diagnostic device even in emergency sites

    Development of a Microwave Imaging System for Brain Injury

    Get PDF

    Microwave Imaging Approach for Breast Cancer Detection Using a Tapered Slot Antenna Loaded with Parasitic Components.

    Get PDF
    In this paper, a wideband antenna is proposed for ultra-wideband microwave imaging applications. The antenna is comprised of a tapered slot ground, a rectangular slotted patch and four star-shaped parasitic components. The added slotted patch is shown to be effective in improving the bandwidth and gain. The proposed antenna system provides a realized gain of 6 dBi, an efficiency of around 80% on the radiation bandwidth, and a wide impedance bandwidth (S11 < -10 dB) of 6.3 GHz (from 3.8 to 10.1 GHz). This supports a true wideband operation. Furthermore, the fidelity factor for face-to-face (FtF) direction is 91.6%, and for side by side (SbS) is 91.2%. This proves the excellent directionality and less signal distortion of the designed antenna. These high figures establish the potential use of the proposed antenna for imaging. A heterogeneous breast phantom with dielectric characteristics identical to actual breast tissue with the presence of tumors was constructed for experimental validation. An antenna array of the proposed antenna element was situated over an artificial breast to collect reflected and transmitted waves for tumor characterization. Finally, an imaging algorithm was used to process the retrieved data to recreate the image in order to detect the undesirable tumor object inside the breast phantom

    A Microwave Imaging Device for Detecting Contaminants in Water-based Food Products

    Get PDF
    Food and beverage industries are paying an increasing attention to the development of new technologies for non-invasive assessment of food products. In particular, there is a need of deploying tools to detect low-density plastic, rubber, wood and glass that are unlikely to be detected by X-Rays, currently used in the most powerful commercial systems. To this end, we propose a microwave-based device, exploiting the dielectric contrast between potential intrusions (e.g., plastic fragments) and the surrounding medium, represented by the food/beverage product. In particular, this work aims to numerically assess this principle of detection to water-based products that are, due to the medium losses, a challenging category at microwaves. An antennas array surrounds the object moving along the production line, to monitor the electromagnetic signal variations with respect to a reference case. The working frequency is chosen by selecting a proper trade-off between penetration depth and image resolution. Then, a procedure, based on the application of the distorted-Born approximation is applied to reconstruct a 3-D image of the contaminant position. Finally, the successful detection of a millimetric-sized plastic sphere is presented in the case of a common commercial bottle filled with water

    Development of a Real-time Ultra-wideband See Through Wall Imaging Radar System

    Get PDF
    Ultra-Wideband (UWB) See-Through-Wall (STW) technology has emerged as a musthave enabling technology by both the military and commercial sectors. As a pioneer in this area, we have led the research in addressing many of the fundamental STW questions. This dissertation is to investigate and resolve a few hurdles in advancing this technology, and produce a realizable high performance STW platform system, which will aid the STW community to find the ultimate answer through experimental and theoretical work. The architectures of a realizable STW imaging system are thoroughly examined and studied. We present both a conceptual system based on RF instruments and a standalone real-time system based on custom design, which utilize reconfigurable design architecture and allows scaling down/up to a desired UWB operating frequency with little difficulty. The systems will serve as a high performance platform for STW study and other related UWB applications. Along the way to a complete STW system, we have developed a simplified transmission line model for wall characteristic prediction; we have developed a scalable synthetic aperture array including both the RF part and the switch control/synchronization part; we have proposed a cost-effective and efficient UWB data acquisition method for real-time STW application based on equivalent-time sampling method. The measurement results reported here include static image formation and tracking moveable targets behind the wall. Even though digital signal processing to generate radar images is not the focus of this research, simple methods for image formation have been implemented and results are very encouraging

    Electromagnetic device for axillary Lymph Node diagnosis

    Get PDF
    The diagnosis of axillary lymph nodes (ALNs) is fundamental to determine breast cancer staging before making therapeutical decisions. Non-invasive medical imaging techniques are often used to diagnose ALNs, but they lack sensitivity and specificity. This thesis aims to contribute to the development of microwave imaging (MWI) prototype system to detect and diagnose ALNs. The dielectric properties of freshly excised animal lymph nodes (LNs) and human ALNs are measured (0.5-8.5GHz) with the Open-Ended Coaxial-Probe technique. The results show that the relative permittivity of healthy ALNs ranges between 30 and 50 at 4.5GHz, which contrasts well with the surrounding fat tissue, potentially enabling ALN detection with MWI. Additionally, the effects of freezing and defrosting of biological tissue dielectric properties are studied, which is motivated by the possibility of measuring previously frozen and defrosted LNs. The results suggest that measuring defrosted tissues does not affect the estimation of their dielectric properties by more than 9% at 4.5GHz, paving the way to measure previously frozen LN. The measured ALN dielectric properties are used to develop an anatomically realistic axillary phantom. The phantom derives from the segmentation of a thoracic computed-tomography scan, and it is made of polymeric containers filled with appropriate tissue mimicking liquids, representing fat and muscle. Finally, ALN microwave tomography is tested (0.5-2.5GHz) on the developed anthropomorphic phantom, using the distorted Born iterative method. The numerical results show that: (i) prior knowledge on the position of muscle tissue is fundamental for ALN detection; (ii) performing two-step measurements, with the antenna set in two different angular positions, can increase the amount of retrievable information, and enhance imaging results. Regarding experimental results, the proposed system can detect an ALN in different positions in the axillary region, which motivates further studies on ALN MWI
    corecore