442 research outputs found

    Is the timed-up and go test feasible in mobile devices? A systematic review

    Get PDF
    The number of older adults is increasing worldwide, and it is expected that by 2050 over 2 billion individuals will be more than 60 years old. Older adults are exposed to numerous pathological problems such as Parkinson’s disease, amyotrophic lateral sclerosis, post-stroke, and orthopedic disturbances. Several physiotherapy methods that involve measurement of movements, such as the Timed-Up and Go test, can be done to support efficient and effective evaluation of pathological symptoms and promotion of health and well-being. In this systematic review, the authors aim to determine how the inertial sensors embedded in mobile devices are employed for the measurement of the different parameters involved in the Timed-Up and Go test. The main contribution of this paper consists of the identification of the different studies that utilize the sensors available in mobile devices for the measurement of the results of the Timed-Up and Go test. The results show that mobile devices embedded motion sensors can be used for these types of studies and the most commonly used sensors are the magnetometer, accelerometer, and gyroscope available in off-the-shelf smartphones. The features analyzed in this paper are categorized as quantitative, quantitative + statistic, dynamic balance, gait properties, state transitions, and raw statistics. These features utilize the accelerometer and gyroscope sensors and facilitate recognition of daily activities, accidents such as falling, some diseases, as well as the measurement of the subject's performance during the test execution.info:eu-repo/semantics/publishedVersio

    A Wireless Flexible Sensorized Insole for Gait Analysis

    Get PDF
    This paper introduces the design and development of a novel pressure-sensitive foot insole for real-time monitoring of plantar pressure distribution during walking. The device consists of a flexible insole with 64 pressure-sensitive elements and an integrated electronic board for high-frequency data acquisition, pre-filtering, and wireless transmission to a remote data computing/storing unit. The pressure-sensitive technology is based on an optoelectronic technology developed at Scuola Superiore Sant'Anna. The insole is a low-cost and low-power battery-powered device. The design and development of the device is presented along with its experimental characterization and validation with healthy subjects performing a task of walking at different speeds, and benchmarked against an instrumented force platform

    Optimal locations and computational frameworks of FSR and IMU sensors for measuring gait abnormalities

    Get PDF
    Neuromuscular diseases cause abnormal joint movements and drastically alter gait patterns in patients. The analysis of abnormal gait patterns can provide clinicians with an in-depth insight into implementing appropriate rehabilitation therapies. Wearable sensors are used to measure the gait patterns of neuromuscular patients due to their non-invasive and cost-efficient characteristics. FSR and IMU sensors are the most popular and efficient options. When assessing abnormal gait patterns, it is important to determine the optimal locations of FSRs and IMUs on the human body, along with their computational framework. The gait abnormalities of different types and the gait analysis systems based on IMUs and FSRs have therefore been investigated. After studying a variety of research articles, the optimal locations of the FSR and IMU sensors were determined by analysing the main pressure points under the feet and prime anatomical locations on the human body. A total of seven locations (the big toe, heel, first, third, and fifth metatarsals, as well as two close to the medial arch) can be used to measure gate cycles for normal and flat feet. It has been found that IMU sensors can be placed in four standard anatomical locations (the feet, shank, thigh, and pelvis). A section on computational analysis is included to illustrate how data from the FSR and IMU sensors are processed. Sensor data is typically sampled at 100 Hz, and wireless systems use a range of microcontrollers to capture and transmit the signals. The findings reported in this article are expected to help develop efficient and cost-effective gait analysis systems by using an optimal number of FSRs and IMUs

    Development of a self-powered piezo-resistive smart insole equipped with low-power BLE connectivity for remote gait monitoring

    Get PDF
    The evolution of low power electronics and the availability of new smart materials are opening new frontiers to develop wearable systems for medical applications, lifestyle monitoring, and performance detection. This paper presents the development and realization of a novel smart insole for monitoring the plantar pressure distribution and gait parameters; indeed, it includes a piezoresistive sensing matrix based on a Velostat layer for transducing applied pressure into an electric signal. At first, an accurate and complete characterization of Velostat-based pressure sensors is reported as a function of sizes, support material, and pressure trend. The realization and testing of a low-cost and reliable piezoresistive sensing matrix based on a sandwich structure are discussed. This last is interfaced with a low power conditioning and processing section based on an Arduino Lilypad board and an analog multiplexer for acquiring the pressure data. The insole includes a 3- axis capacitive accelerometer for detecting the gait parameters (swing time and stance phase time) featuring the walking. A Bluetooth Low Energy (BLE) 5.0 module is included for transmitting in real-time the acquired data toward a PC, tablet or smartphone, for displaying and processing them using a custom Processing¼ application. Moreover, the smart insole is equipped with a piezoelectric harvesting section for scavenging energy from walking. The onfield tests indicate that for a walking speed higher than 1 ms−1, the device’s power requirements (i.e., P = 5.84 mW ) was fulfilled. However, more than 9 days of autonomy are guaranteed by the integrated 380-mAh Lipo battery in the total absence of energy contributions from the harvesting section

    TRIBOELECTRIC NANOGENERATORS (TENG): FACTORS AFFECTING ITS EFFICIENCY AND APPLICATIONS

    Get PDF
    The demand for energy is increasing tremendously with modernization of the technology and requires new sources of renewable energy. The triboelectric nanogenerators (TENG) are capable of harvesting ambient energy and converting it into electricity with the process of triboelectrification and electrostatic-induction. TENG can convert mechanical energy available in the form of vibrations, rotation, wind and human motions etc., into electrical energy there by developing a great scope for scavenging large scale energy. In this review paper, we have discussed various modes of operation of TENG along with the various factors contributing towards its efficiency and applications in wearable electronics

    Physical Behavior in Older Persons during Daily Life: Insights from Instrumented Shoes.

    Get PDF
    Activity level and gait parameters during daily life are important indicators for clinicians because they can provide critical insights into modifications of mobility and function over time. Wearable activity monitoring has been gaining momentum in daily life health assessment. Consequently, this study seeks to validate an algorithm for the classification of daily life activities and to provide a detailed gait analysis in older adults. A system consisting of an inertial sensor combined with a pressure sensing insole has been developed. Using an algorithm that we previously validated during a semi structured protocol, activities in 10 healthy elderly participants were recorded and compared to a wearable reference system over a 4 h recording period at home. Detailed gait parameters were calculated from inertial sensors. Dynamics of physical behavior were characterized using barcodes that express the measure of behavioral complexity. Activity classification based on the algorithm led to a 93% accuracy in classifying basic activities of daily life, i.e., sitting, standing, and walking. Gait analysis emphasizes the importance of metrics such as foot clearance in daily life assessment. Results also underline that measures of physical behavior and gait performance are complementary, especially since gait parameters were not correlated to complexity. Participants gave positive feedback regarding the use of the instrumented shoes. These results extend previous observations in showing the concurrent validity of the instrumented shoes compared to a body-worn reference system for daily-life physical behavior monitoring in older adults

    Simultaneous Bayesian recognition of locomotion and gait phases with wearable sensors

    Get PDF
    Recognition of movement is a crucial process to assist humans in activities of daily living, such as walking. In this work, a high-level method for the simultaneous recognition of locomotion and gait phases using wearable sensors is presented. A Bayesian formulation is employed to iteratively accumulate evidence to reduce uncertainty, and to improve the recognition accuracy. This process uses a sequential analysis method to autonomously make decisions, whenever the recognition system perceives that there is enough evidence accumulated. We use data from three wearable sensors, attached to the thigh, shank, and foot of healthy humans. Level-ground walking, ramp ascent and descent activities are used for data collection and recognition. In addition, an approach for segmentation of the gait cycle for recognition of stance and swing phases is presented. Validation results show that the simultaneous Bayesian recognition method is capable to recognize walking activities and gait phases with mean accuracies of 99.87% and 99.20%. This process requires a mean of 25 and 13 sensor samples to make a decision for locomotion mode and gait phases, respectively. The recognition process is analyzed using different levels of confidence to show that our method is highly accurate, fast, and adaptable to specific requirements of accuracy and speed. Overall, the simultaneous Bayesian recognition method demonstrates its benefits for recognition using wearable sensors, which can be employed to provide reliable assistance to humans in their walking activities

    Wearable Sensors and Smart Devices to Monitor Rehabilitation Parameters and Sports Performance: An Overview

    Get PDF
    A quantitative evaluation of kinetic parameters, the joint’s range of motion, heart rate, and breathing rate, can be employed in sports performance tracking and rehabilitation monitoring following injuries or surgical operations. However, many of the current detection systems are expensive and designed for clinical use, requiring the presence of a physician and medical staff to assist users in the device’s positioning and measurements. The goal of wearable sensors is to overcome the limitations of current devices, enabling the acquisition of a user’s vital signs directly from the body in an accurate and non–invasive way. In sports activities, wearable sensors allow athletes to monitor performance and body movements objectively, going beyond the coach’s subjective evaluation limits. The main goal of this review paper is to provide a comprehensive overview of wearable technologies and sensing systems to detect and monitor the physiological parameters of patients during post–operative rehabilitation and athletes’ training, and to present evidence that supports the efïŹcacy of this technology for healthcare applications. First, a classiïŹcation of the human physiological parameters acquired from the human body by sensors attached to sensitive skin locations or worn as a part of garments is introduced, carrying important feedback on the user’s health status. Then, a detailed description of the electromechanical transduction mechanisms allows a comparison of the technologies used in wearable applications to monitor sports and rehabilitation activities. This paves the way for an analysis of wearable technologies, providing a comprehensive comparison of the current state of the art of available sensors and systems. Comparative and statistical analyses are provided to point out useful insights for deïŹning the best technologies and solutions for monitoring body movements. Lastly, the presented review is compared with similar ones reported in the literature to highlight its strengths and novelties
    • 

    corecore