5,035 research outputs found
Heart Rate Monitoring During Different Lung Volume Phases Using Seismocardiography
Seismocardiography (SCG) is a non-invasive method that can be used for
cardiac activity monitoring. This paper presents a new electrocardiogram (ECG)
independent approach for estimating heart rate (HR) during low and high lung
volume (LLV and HLV, respectively) phases using SCG signals. In this study,
SCG, ECG, and respiratory flow rate (RFR) signals were measured simultaneously
in 7 healthy subjects. The lung volume information was calculated from the RFR
and was used to group the SCG events into low and high lung-volume groups. LLV
and HLV SCG events were then used to estimate the subjects HR as well as the HR
during LLV and HLV in 3 different postural positions, namely supine, 45 degree
heads-up, and sitting. The performance of the proposed algorithm was tested
against the standard ECG measurements. Results showed that the HR estimations
from the SCG and ECG signals were in a good agreement (bias of 0.08 bpm). All
subjects were found to have a higher HR during HLV (HR) compared
to LLV (HR) at all postural positions. The
HR/HR ratio was 1.110.07, 1.080.05,
1.090.04, and 1.090.04 (meanSD) for supine, 45 degree-first
trial, 45 degree-second trial, and sitting positions, respectively. This heart
rate variability may be due, at least in part, to the well-known respiratory
sinus arrhythmia. HR monitoring from SCG signals might be used in different
clinical applications including wearable cardiac monitoring systems
Precision medicine and artificial intelligence : a pilot study on deep learning for hypoglycemic events detection based on ECG
Tracking the fluctuations in blood glucose levels is important for healthy subjects and crucial diabetic patients. Tight glucose monitoring reduces the risk of hypoglycemia, which can result in a series of complications, especially in diabetic patients, such as confusion, irritability, seizure and can even be fatal in specific conditions. Hypoglycemia affects the electrophysiology of the heart. However, due to strong inter-subject heterogeneity, previous studies based on a cohort of subjects failed to deploy electrocardiogram (ECG)-based hypoglycemic detection systems reliably. The current study used personalised medicine approach and Artificial Intelligence (AI) to automatically detect nocturnal hypoglycemia using a few heartbeats of raw ECG signal recorded with non-invasive, wearable devices, in healthy individuals, monitored 24 hours for 14 consecutive days. Additionally, we present a visualisation method enabling clinicians to visualise which part of the ECG signal (e.g., T-wave, ST-interval) is significantly associated with the hypoglycemic event in each subject, overcoming the intelligibility problem of deep-learning methods. These results advance the feasibility of a real-time, non-invasive hypoglycemia alarming system using short excerpts of ECG signal
Precision medicine and artificial intelligence : a pilot study on deep learning for hypoglycemic events detection based on ECG
Tracking the fluctuations in blood glucose levels is important for healthy subjects and crucial diabetic patients. Tight glucose monitoring reduces the risk of hypoglycemia, which can result in a series of complications, especially in diabetic patients, such as confusion, irritability, seizure and can even be fatal in specific conditions. Hypoglycemia affects the electrophysiology of the heart. However, due to strong inter-subject heterogeneity, previous studies based on a cohort of subjects failed to deploy electrocardiogram (ECG)-based hypoglycemic detection systems reliably. The current study used personalised medicine approach and Artificial Intelligence (AI) to automatically detect nocturnal hypoglycemia using a few heartbeats of raw ECG signal recorded with non-invasive, wearable devices, in healthy individuals, monitored 24 hours for 14 consecutive days. Additionally, we present a visualisation method enabling clinicians to visualise which part of the ECG signal (e.g., T-wave, ST-interval) is significantly associated with the hypoglycemic event in each subject, overcoming the intelligibility problem of deep-learning methods. These results advance the feasibility of a real-time, non-invasive hypoglycemia alarming system using short excerpts of ECG signal
Automated ECG Analysis for Localizing Thrombus in Culprit Artery Using Rule Based Information Fuzzy Network
Cardio-vascular diseases are one of the foremost causes of mortality in today’s world. The prognosis for cardiovascular diseases is usually done by ECG signal, which is a simple 12-lead Electrocardiogram (ECG) that gives complete information about the function of the heart including the amplitude and time interval of P-QRST-U segment. This article recommends a novel approach to identify the location of thrombus in culprit artery using the Information Fuzzy Network (IFN). Information Fuzzy Network, being a supervised machine learning technique, takes known evidences based on rules to create a predicted classification model with thrombus location obtained from the vast input ECG data. These rules are well-defined procedures for selecting hypothesis that best fits a set of observations. Results illustrate that the recommended approach yields an accurateness of 92.30%. This novel approach is shown to be a viable ECG analysis approach for identifying the culprit artery and thus localizing the thrombus
Deep learning analysis of the myocardium in coronary CT angiography for identification of patients with functionally significant coronary artery stenosis
In patients with coronary artery stenoses of intermediate severity, the
functional significance needs to be determined. Fractional flow reserve (FFR)
measurement, performed during invasive coronary angiography (ICA), is most
often used in clinical practice. To reduce the number of ICA procedures, we
present a method for automatic identification of patients with functionally
significant coronary artery stenoses, employing deep learning analysis of the
left ventricle (LV) myocardium in rest coronary CT angiography (CCTA). The
study includes consecutively acquired CCTA scans of 166 patients with FFR
measurements. To identify patients with a functionally significant coronary
artery stenosis, analysis is performed in several stages. First, the LV
myocardium is segmented using a multiscale convolutional neural network (CNN).
To characterize the segmented LV myocardium, it is subsequently encoded using
unsupervised convolutional autoencoder (CAE). Thereafter, patients are
classified according to the presence of functionally significant stenosis using
an SVM classifier based on the extracted and clustered encodings. Quantitative
evaluation of LV myocardium segmentation in 20 images resulted in an average
Dice coefficient of 0.91 and an average mean absolute distance between the
segmented and reference LV boundaries of 0.7 mm. Classification of patients was
evaluated in the remaining 126 CCTA scans in 50 10-fold cross-validation
experiments and resulted in an area under the receiver operating characteristic
curve of 0.74 +- 0.02. At sensitivity levels 0.60, 0.70 and 0.80, the
corresponding specificity was 0.77, 0.71 and 0.59, respectively. The results
demonstrate that automatic analysis of the LV myocardium in a single CCTA scan
acquired at rest, without assessment of the anatomy of the coronary arteries,
can be used to identify patients with functionally significant coronary artery
stenosis.Comment: This paper was submitted in April 2017 and accepted in November 2017
for publication in Medical Image Analysis. Please cite as: Zreik et al.,
Medical Image Analysis, 2018, vol. 44, pp. 72-8
- …