436 research outputs found

    Organic electrolytic photocapacitors for stimulation of the mouse somatosensory cortex

    Get PDF
    Objective. For decades electrical stimulation has been used in neuroscience to investigate brain networks and been deployed clinically as a mode of therapy. Classically, all methods of electrical stimulation require implanted electrodes to be connected in some manner to an apparatus which provides power for the stimulation itself. Approach. We show the use of novel organic electronic devices, specifically organic electrolytic photocapacitors (OEPCs), which can be activated when illuminated with deep-red wavelengths of light and correspondingly do not require connections with external wires or power supplies when implanted at various depths in vivo. Main results. We stimulated cortical brain tissue of mice with devices implanted subcutaneously, as well as beneath both the skin and skull to demonstrate a wireless stimulation of the whisker motor cortex. Devices induced both a behavior response (whisker movement) and a sensory response in the corresponding sensory cortex. Additionally, we showed that coating OEPCs with a thin layer of a conducting polymer formulation (PEDOT:PSS) significantly increases their charge storage capacity, and can be used to further optimize the applied photoelectrical stimulation. Significance. Overall, this new technology can provide an on-demand electrical stimulation by simply using an OEPC and a deep-red wavelength illumination. Wires and interconnects to provide power to implanted neurostimulation electrodes are often problematic in freely-moving animal research and with implanted electrodes for long-term therapy in patients. Our wireless brain stimulation opens new perspectives for wireless electrical stimulation for applications in fundamental neurostimulation and in chronic therapy

    Stepper microactuators driven by ultrasonic power transfer

    No full text
    Advances in miniature devices for biomedical applications are creating ever-increasing requirements for their continuous, long lasting, and reliable energy supply, particularly for implanted devices. As an alternative to bulky and cost inefficient batteries that require occasional recharging and replacement, energy harvesting and wireless power delivery are receiving increased attention. While the former is generally only suited for low-power diagnostic microdevices, the latter has greater potential to extend the functionality to include more energy demanding therapeutic actuation such as drug release, implant mechanical adjustment or microsurgery. This thesis presents a novel approach to delivering wireless power to remote medical microdevices with the aim of satisfying higher energy budgets required for therapeutic functions. The method is based on ultrasonic power delivery, the novelty being that actuation is powered by ultrasound directly rather than via piezoelectric conversion. The thesis describes a coupled mechanical system remotely excited by ultrasound and providing conversion of acoustic energy into motion of a MEMS mechanism using a receiving membrane coupled to a discrete oscillator. This motion is then converted into useful stepwise actuation through oblique mechanical impact. The problem of acoustic and mechanical impedance mismatch is addressed. Several analytical and numerical models of ultrasonic power delivery into the human body are developed. Major design challenges that have to be solved in order to obtain acceptable performance under specified operating conditions and with minimum wave reflections are discussed. A novel microfabrication process is described, and the resulting proof-of-concept devices are successfully characterized.Open Acces

    Towards respiratory muscle-protective mechanical ventilation in the critically ill: technology to monitor and assist physiology

    Get PDF
    Inadequate delivery of ventilatory assist and unphysiological respiratory drive may severely worsen respiratory muscle function in mechanically ventilated critically ill patients. Diaphragm weakness in these patients is exceedingly common (>60% of patients) and associated with poor clinical outcomes, including difficult ventilator liberation, increased risks of intensive care unit (ICU) and hospital readmission, and mortality. The underlying mechanisms of diaphragm dysfunction were extensively discussed in this thesis. Pathways primarily include the development of diaphragm disuse atrophy due to muscle inactivity or low respiratory drive (strong clinical evidence), and diaphragm injury as a result of excessive breathing effort due to insufficient ventilator assist or excessive respiratory drive (moderate evidence, mostly from experimental work). Excessive breathing effort may also worsen lung injury through pathways that include high lung stress and strain, pendelluft, increased lung perfusion, and patient-ventilator dyssynchrony. Relatively little attention has been paid to the effects of critical illness and mechanical ventilation on the expiratory muscles; however, dysfunction of these muscles has been linked to inadequate central airway clearance and extubation failure. The motivation for performing the work presented in this thesis was the hypothesis that maintaining physiological levels of respiratory muscle activity under mechanical ventilation could prevent or attenuate the development respiratory muscle weakness, and hence, improve patient outcomes. This strategy, integrated with lung-protective ventilation, was recently proposed by international experts from different professional societies (this thesis), and is referred to as a combined lung and diaphragm-protective ventilation approach. Today, an important barrier for implementing and evaluating such an approach is the lack of feasible, reliable and well-understood modalities to assess breathing effort at the bedside, as well as strategies for assisting and restoring respiratory muscle function during mechanical ventilation. Furthermore, monitoring breathing effort is crucial to identify potential relationships between patient management and detrimental respiratory (muscle) function that can be targeted to improve clinical outcomes. In this thesis we identified and improved monitoring modalities for the diaphragm (Part I), we investigated the impact of mechanical ventilation on the respiratory pump, especially the diaphragm (Part II), and we evaluated a novel strategy for maintaining expiratory muscle activity under mechanical ventilation (Part III)

    Aerospace medicine and biology: A continuing bibliography with indexes (supplement 335)

    Get PDF
    This bibliography lists 143 reports, articles and other documents introduced into the NASA Scientific and Technical Information System during March, 1990. Subject coverage includes: aerospace medicine and psychology, life support systems and controlled environments, safety equipment, exobiology and extraterrestrial life, and flight crew behavior and performance

    CIR-Myo News: Proceedings of the 2014 Spring Padua Muscle Days

    Get PDF
    Not available

    Biosignal‐based human–machine interfaces for assistance and rehabilitation : a survey

    Get PDF
    As a definition, Human–Machine Interface (HMI) enables a person to interact with a device. Starting from elementary equipment, the recent development of novel techniques and unobtrusive devices for biosignals monitoring paved the way for a new class of HMIs, which take such biosignals as inputs to control various applications. The current survey aims to review the large literature of the last two decades regarding biosignal‐based HMIs for assistance and rehabilitation to outline state‐of‐the‐art and identify emerging technologies and potential future research trends. PubMed and other databases were surveyed by using specific keywords. The found studies were further screened in three levels (title, abstract, full‐text), and eventually, 144 journal papers and 37 conference papers were included. Four macrocategories were considered to classify the different biosignals used for HMI control: biopotential, muscle mechanical motion, body motion, and their combinations (hybrid systems). The HMIs were also classified according to their target application by considering six categories: prosthetic control, robotic control, virtual reality control, gesture recognition, communication, and smart environment control. An ever‐growing number of publications has been observed over the last years. Most of the studies (about 67%) pertain to the assistive field, while 20% relate to rehabilitation and 13% to assistance and rehabilitation. A moderate increase can be observed in studies focusing on robotic control, prosthetic control, and gesture recognition in the last decade. In contrast, studies on the other targets experienced only a small increase. Biopotentials are no longer the leading control signals, and the use of muscle mechanical motion signals has experienced a considerable rise, especially in prosthetic control. Hybrid technologies are promising, as they could lead to higher performances. However, they also increase HMIs’ complex-ity, so their usefulness should be carefully evaluated for the specific application

    A cumulative index to the 1976 issues of a continuing bibliography on Aerospace Medicine and Biology

    Get PDF
    This publication is a cumulative index to the abstracts contained in Supplements 151 through 162 of Aerospace Medicine and Biology: A continuing bibliography. It includes three indexes - subject, personal author, and corporate source
    • 

    corecore