5,346 research outputs found

    IEEE Access Special Section Editorial: Energy Management in Buildings

    Get PDF
    Energy usage in buildings has become a critical concern globally, and with that, the concept of energy management in buildings has emerged to help tackle these challenges. The energy management system provides a new opportunity for the building's energy requirements, and is an essential method for energy service, i.e., energy saving, consumption,

    False data injection attack detection in smart grid

    Get PDF
    Smart grid is a distributed and autonomous energy delivery infrastructure that constantly monitors the operational state of its overall network using smart techniques and state estimation. State estimation is a powerful technique that is used to determine the overall operational state of the system based on a limited set of measurements collected through metering systems. Cyber-attacks pose serious risks to a smart grid state estimation that can cause disruptions and power outages resulting in huge economical losses and are therefore a big concern to a reliable national grid operation. False data injection attacks (FDIAs), engineered on the basis of the knowledge of the network configuration, are difficult to detect using the traditional data detection mechanisms. These detection schemes have been found vulnerable and failed to detect these FDIAs. FDIAs specifically target the state data and can manipulate the state measurements in such a way that these false measurements appear real to the main control systems. This research work explores the possibility of FDIA detection using state estimation in a distributed and partitioned smart grid. In order to detect FDIAs we use measurements for residual-based testing which creates an objective function; and the probability of erroneous data is determined from this residual test. In this test, a preset threshold is determined based on the prior history of the state data. FDIA cases are simulated within a smart grid considering that the Chi-square detection state estimator fails in identifying such attacks. We compute the objective function using the standard weighted least problem and then test the objective function against the value in the Chi-square table. The gain matrix and the Jacobian matrix are computed. The state variables are computed in the form of a voltage magnitude. The state variables are computed after the inception of an attack to assess these state magnitude results. Different sizes of partitioning are used to improve the overall sensitivity of the Chi-square results. Our additional estimator is based on a Kalman estimation that consists of the state prediction and state correction steps. In the first step, it obtains the state and matrix covariance prediction, and in the second step, it calculates the Kalman gain and the state and matrix covariance update steps. The set of points is created for the state vector x at a time instant t. The initial vector and covariance matrix are based on a priori knowledge of the historical estimates. A set of sigma points is estimated by the state update function. Sigma points refer to the minimal set of sampling points that are selected and transformed using nonlinear function, and the new mean and the covariance are formed out of these transformed points. The idea behind this is that it is easier to compute a Gaussian distribution than an arbitrary nonlinear function. The filter gain, the mean and the covariance are used to estimate the next state. Our simulation results show that the combination of Kalman estimation and distributed state estimation improves the overall stability index and vulnerability assessment score of the smart grid. We built a stability index table for a smart grid based on the state estimates value after the inception of an FDIA. The vulnerability assessment score of the smart grid is based on common vulnerability scoring system (CVSS) and state estimates under the influence of an FDIA. The simulations are conducted in the MATPOWER program and different electrical bus systems such as IEEE 14, 30, 39, 118 and 300 are tested. All the contributions have been published in reputable journals and conferences.Doctor of Philosoph

    Digital Twinning in Smart Grid Networks: Interplay, Resource Allocation and Use Cases

    Full text link
    Motivated by climate change, increasing industrialization and energy reliability concerns, the smart grid is set to revolutionize traditional power systems. Moreover, the exponential annual rise in number of grid-connected users and emerging key players e.g. electric vehicles strain the limited radio resources, which stresses the need for novel and scalable resource management techniques. Digital twin is a cutting-edge virtualization technology that has shown great potential by offering solutions for inherent bottlenecks in traditional wireless networks. In this article, we set the stage for various roles digital twinning can fulfill by optimizing congested radio resources in a proactive and resilient smart grid. Digital twins can help smart grid networks through real-time monitoring, advanced precise modeling and efficient radio resource allocation for normal operations and service restoration following unexpected events. However, reliable real-time communications, intricate abstraction abilities, interoperability with other smart grid technologies, robust computing capabilities and resilient security schemes are some open challenges for future work on digital twins.Comment: 7 pages, 3 figure

    An Energy Aware and Secure MAC Protocol for Tackling Denial of Sleep Attacks in Wireless Sensor Networks

    Get PDF
    Wireless sensor networks which form part of the core for the Internet of Things consist of resource constrained sensors that are usually powered by batteries. Therefore, careful energy awareness is essential when working with these devices. Indeed,the introduction of security techniques such as authentication and encryption, to ensure confidentiality and integrity of data, can place higher energy load on the sensors. However, the absence of security protection c ould give room for energy drain attacks such as denial of sleep attacks which have a higher negative impact on the life span ( of the sensors than the presence of security features. This thesis, therefore, focuses on tackling denial of sleep attacks from two perspectives A security perspective and an energy efficiency perspective. The security perspective involves evaluating and ranking a number of security based techniques to curbing denial of sleep attacks. The energy efficiency perspective, on the other hand, involves exploring duty cycling and simulating three Media Access Control ( protocols Sensor MAC, Timeout MAC andTunableMAC under different network sizes and measuring different parameters such as the Received Signal Strength RSSI) and Link Quality Indicator ( Transmit power, throughput and energy efficiency Duty cycling happens to be one of the major techniques for conserving energy in wireless sensor networks and this research aims to answer questions with regards to the effect of duty cycles on the energy efficiency as well as the throughput of three duty cycle protocols Sensor MAC ( Timeout MAC ( and TunableMAC in addition to creating a novel MAC protocol that is also more resilient to denial of sleep a ttacks than existing protocols. The main contributions to knowledge from this thesis are the developed framework used for evaluation of existing denial of sleep attack solutions and the algorithms which fuel the other contribution to knowledge a newly developed protocol tested on the Castalia Simulator on the OMNET++ platform. The new protocol has been compared with existing protocols and has been found to have significant improvement in energy efficiency and also better resilience to denial of sleep at tacks Part of this research has been published Two conference publications in IEEE Explore and one workshop paper
    corecore