10 research outputs found

    Modelling, Simulation and Data Analysis in Acoustical Problems

    Get PDF
    Modelling and simulation in acoustics is currently gaining importance. In fact, with the development and improvement of innovative computational techniques and with the growing need for predictive models, an impressive boost has been observed in several research and application areas, such as noise control, indoor acoustics, and industrial applications. This led us to the proposal of a special issue about “Modelling, Simulation and Data Analysis in Acoustical Problems”, as we believe in the importance of these topics in modern acoustics’ studies. In total, 81 papers were submitted and 33 of them were published, with an acceptance rate of 37.5%. According to the number of papers submitted, it can be affirmed that this is a trending topic in the scientific and academic community and this special issue will try to provide a future reference for the research that will be developed in coming years

    Sequential grouping constraints on across-channel auditory processing

    Get PDF

    Søren Buus. Thirty years of psychoacoustic inspiration

    Get PDF

    Sequential grouping constraints on across‐channel auditory processing

    Full text link

    A nonparametric temperature controller with nonlinear negative reaction for multi-point rapid MR-guided HIFU ablation

    No full text
    International audienceMagnetic resonance-guided high intensity focused ultrasound (MRgHIFU) is a noninvasive method for thermal ablation, which exploits the capabilities of magnetic resonance imaging (MRI) for excellent visualization of the target and for near real-time thermometry. Oncological quality of ablation may be obtained by volumetric sonication under automatic feedback control of the temperature. For this purpose, a new nonparametric (i.e., model independent) temperature controller, using nonlinear negative reaction, was designed and evaluated for the iterated sonication of a prescribed pattern of foci. The main objective was to achieve the same thermal history at each sonication point during volumetric MRgHIFU. Differently sized linear and circular trajectories were investigated ex vivo and in vivo using a phased-array HIFU transducer. A clinical 3T MRI scanner was used and the temperature elevation was measured in five slices simultaneously with a voxel size of 1 x 1 x 5 mm(3) and temporal resolution of 4 s. In vivo results indicated a similar thermal history of each sonicated focus along the prescribed pattern, that was 17.3 +/- 0.5 degrees C as compared to 16 degrees C prescribed temperature elevation. The spatio-temporal control of the temperature also enabled meaningful comparison of various sonication patterns in terms of dosimetry and near-field safety. The thermal build-up tended to drift downwards in the HIFU transducer with a circular scan
    corecore