3,250 research outputs found

    Non-Invasive Estimation of Right Atrial Pressure Using a Semi-Automated Echocardiographic Tool for Inferior Vena Cava Edge-Tracking

    Get PDF
    The non-invasive estimation of right atrial pressure (RAP) would be a key advancement in several clinical scenarios, in which the knowledge of central venous filling pressure is vital for patients’ management. The echocardiographic estimation of RAP proposed by Guidelines, based on inferior vena cava (IVC) size and respirophasic collapsibility, is exposed to operator and patient dependent variability. We propose novel methods, based on semi-automated edge-tracking of IVC size and cardiac collapsibility (cardiac caval index—CCI), tested in a monocentric retrospective cohort of patients undergoing echocardiography and right heart catheterization (RHC) within 24 h in condition of clinical and therapeutic stability (170 patients, age 64 ± 14, male 45%, with pulmonary arterial hypertension, heart failure, valvular heart disease, dyspnea, or other pathologies). IVC size and CCI were integrated with other standard echocardiographic features, selected by backward feature selection and included in a linear model (LM) and a support vector machine (SVM), which were cross-validated. Three RAP classes (low 10 mmHg) were generated and RHC values used as comparator. LM and SVM showed a higher accuracy than Guidelines (63%, 71%, and 61% for LM, SVM, and Guidelines, respectively), promoting the integration of IVC and echocardiographic features for an improved non-invasive estimation of RAP

    Pulmonary hypertension and heart failure : physiological markers assessed by cardiovascular magnetic resonance

    Get PDF
    Pulmonary hypertension (PH) is clinically and physiologically associated with heart failure, both with reduced and preserved ejection fraction (HFrEF and HFpEF). In HFpEF, the most likely underlying pathophysiological mechanism is an impairment of left ventricular relaxation named diastolic dysfunction. The close relationship between PH, diastolic dysfunction, and heart failure makes it difficult to clearly distinguish between them in clinical practice. Given the challenges around screening and diagnosis of both PH and diastolic dysfunction, better diagnostic tools are needed to complement the existing ones. Cardiovascular magnetic resonance (CMR) is considered the most accurate imaging modality in the assessment of myocardial anatomy and function. Furthermore, CMR offers the possibility of qualitatively and quantitatively assess blood flow in large and medium vessels. Constant technical innovations push to further develop the current clinical capabilities of CMR and enable better and faster diagnosis of cardiovascular diseases. In this thesis, we aimed to expand the current clinical capabilities of CMR in the diagnosis of pulmonary hypertension and diastolic dysfunction, which are not routinely assessed with this imaging modality. In Study I, we investigated the effect of body position in pulmonary blood flow distribution and documented a new variable, termed pulmonary vascular distensibility reserve, possibly related to left atrial pressure. In Study II, we found that CMR has a higher diagnostic yield than echocardiography for estimation of elevated pulmonary artery pressure. In Study III, CMR estimation of pulmonary artery pressure showed very good agreement with invasively measured pressure, and better sensitivity and accuracy than echocardiography. In Study IV, we developed a high temporal resolution CMR method to measure transmitral blood and myocardial tissue velocities, which had good agreement with echocardiography. Lastly, in Study V, we found that a comprehensive CMR method to diagnose and grade diastolic dysfunction showed very good agreement with echocardiography. These results suggest that novel and established CMR-based methods can diagnose pulmonary hypertension and diastolic dysfunction. Therefore, CMR may one day play an important role in the diagnostic investigation of these pathologies

    Advanced bioimpedance signal processing techniques for hemodynamic monitoring during anesthesia

    Get PDF
    Aplicat embargament des de la data de defensa fins els maig 2020.Cardiac output (CO) defines the blood flow arriving from the heart to the different organs in the body and it is thus a primary determinant of global 02 transport. Cardiac output has traditionally been measured using invasive methods, whose risk sometimes exceeds the advantages of a cardiac output monitoring. In this context, the minimization of risk in new noninvasive technologies for CO monitoring could translate into major advantages for clinicians, hospitals and patients: ease of usage and availability, reduced recovery time, and improved patient outcome. Impedance Cardiography (ICG) is a promising noninvasive technology for cardiac output monitoring but available information on the ICG signals is more scare than other physiological signals such as the electrocardiogram (ECG). The present Doctoral Thesis contributes to the development of signal treatment techniques for the ICG in order to create an innovative hemodynamic monitor. First, an extensive literature review is provided regarding the basics of the clinical background in which cardiac output monitoring is used and concerning the state of the art of cardiac output monitors on the market. This Doctoral Thesis has produced a considerable amount of clinical data which is also explained in detail. These clinical data are also useful to complement the theoretical explanation of patient indices such as heart rate variability, blood flow and blood pressure. In addition, a new method to create synthetic biomedical signals with known time-frequency characteristics is introduced. One of the first analysis in this Doctoral Thesis studies the time difference between peak points of the heart beats in the ECG and the ICG: the RC segment. This RC segment is a measure of the time delay between electrical and mechanical activity of the heart. The relationship of the RC segment with blood pressure and heart interval is analyzed. The concordance of beat durations of both the electrocardiogram and the impedance cardiogram is one of the key results to develop new artefact detection algorithms and the RC could also have an impact in describing the hemodynamics of a patient. Time-frequency distributions (TFDs) are also used to characterize how the frequency content in impedance cardiography signals change with time. Since TFDs are calculated using concrete kernels, a new method to select the best kernel by using synthetic signals is presented. Optimized TFDs of ICG signals are then calculated to extract severa! features which are used to discriminate between different anesthesia states in patients undergoing surgery. TFD-derived features are also used to describe the whole surgical operations. Relationships between TFD-derived features are analyzed and prediction models for cardiac output are designed. These prediction models prove that the TFD-derived features are related to the patients' cardiac output. Finally, a validation study for the qCO monitor is presented. The qCO monitor has been designed using sorne of the techniques which are consequence of this Doctoral Thesis. The main outputs of this work have been protected with a patent which has already been filed. As a conclusion, this Doctoral Thesis has produced a considerable amount of clinical data and a variety of analysis and processing techniques of impedance cardiography signals which have been included into commercial medical devices already available on the market.El gasto cardíaco (GC) define el flujo de sangre que llega desde el corazón a los distintos órganos del cuerpo y es, por tanto, un determinante primario del transporte global de oxígeno. Se ha medido tradicionalmente usando métodos invasivos cuyos riesgos excedían en ocasiones las ventajas de su monitorización. En este contexto, la minimización del riesgo de la monitorización del gasto cardíaco en nuevas tecnologías no invasivas podría traducirse en mayores ventajas para médicos, hospitales y pacientes: facilidad de uso, disponibilidad del equipamiento y menor tiempo de recuperación y mejores resultados en el paciente. La impedancio-cardiografía o cardiografía de impedancia (ICG} es una prometedora tecnología no invasiva para la monitorización del gasto cardíaco. Sin embargo, la información disponible sobre las señales de ICG es más escasa que otras señales fisiológicas como el electrocardiograma (ECG). La presente Tesis Doctoral contribuye al desarrollo de técnicas de tratamiento de señal de ICG para así crear un monitor hemodinámico innovador. En primer lugar, se proporciona una extensa revisión bibliográfica sobre los aspectos básicos del contexto clínico en el que se utiliza la monitorización del gasto cardíaco así como sobre el estado del arte de los monitores de gasto cardíaco que existen en el mercado. Esta Tesis Doctoral ha producido una considerable cantidad de datos clínicos que también se explican en detalle. Dichos datos clínicos también son útiles para complementar las explicaciones teóricas de los índices de paciente de variabilidad cardíaca y el flujo y la presión sanguíneos. Además, se presenta un nuevo método de creación de señales sintéticas biomédicas con características de tiempo-frecuencia conocidas. Uno de los primeros análisis de esta Tesis Doctoral estudia la diferencia temporal entre los picos de los latidos cardíacos del ECG y del ICG: el segmento RC. Este segmento RC es una medida del retardo temporal entre la actividad eléctrica y mecánica del corazón. Se analiza la relación del segmento RC con la presión arterial y el intervalo cardíaco. La concordancia entre la duración de los latidos del ECG y del ICG es uno de los resultados claves para desarrollar nuevos algoritmos de detección de artefactos y el segmento RC también podría ser relevante en la descripción de la hemodinámica de los pacientes. Las distribuciones de tiempo-frecuencia (TFD, por sus siglas en inglés) se utilizan para caracterizar cómo el contenido de las señales de impedancia cardiográfica cambia con el tiempo. Dado que las TFDs deben calcularse usando núcleos (kernels, en inglés) concretos, se presenta un nuevo método para seleccionar el mejor núcleo mediante el uso de señales sintéticas. Las TFDs de ICG optimizadas se calculan para extraer distintas características que son usadas para discriminar entre los diferentes estados de anestesia en pacientes sometidos a procesos quirúrgicos. Las características derivadas de las distribuciones de tiempo-frecuencia también son utilizadas para describir las operaciones quirúrgicas durante toda su extensión temporal. La relación entre dichas características son analizadas y se proponen distintos modelos de predicción para el gasto cardíaco. Estos modelos de predicción demuestran que las características derivadas de las distribuciones tiempo-frecuencia de señales de ICG están relacionadas con el gasto cardíaco de los pacientes. Finalmente, se presenta un estudio de validación del monitor qCO, diseñado con alguna de las técnicas que son consecuencia de esta Tesis Doctoral. Las principales conclusiones de este trabajo han sido protegidas con una patente que ya ha sido registrada. Como conclusión, esta Tesis Doctoral ha producido una considerable cantidad de datos clínicos y una variedad de técnicas de procesado y análisis de señales de cardiografía de impedancia que han sido incluidas en dispositivos biomédicos disponibles en el mercadoPostprint (published version

    Advanced bioimpedance signal processing techniques for hemodynamic monitoring during anesthesia

    Get PDF
    Cardiac output (CO) defines the blood flow arriving from the heart to the different organs in the body and it is thus a primary determinant of global 02 transport. Cardiac output has traditionally been measured using invasive methods, whose risk sometimes exceeds the advantages of a cardiac output monitoring. In this context, the minimization of risk in new noninvasive technologies for CO monitoring could translate into major advantages for clinicians, hospitals and patients: ease of usage and availability, reduced recovery time, and improved patient outcome. Impedance Cardiography (ICG) is a promising noninvasive technology for cardiac output monitoring but available information on the ICG signals is more scare than other physiological signals such as the electrocardiogram (ECG). The present Doctoral Thesis contributes to the development of signal treatment techniques for the ICG in order to create an innovative hemodynamic monitor. First, an extensive literature review is provided regarding the basics of the clinical background in which cardiac output monitoring is used and concerning the state of the art of cardiac output monitors on the market. This Doctoral Thesis has produced a considerable amount of clinical data which is also explained in detail. These clinical data are also useful to complement the theoretical explanation of patient indices such as heart rate variability, blood flow and blood pressure. In addition, a new method to create synthetic biomedical signals with known time-frequency characteristics is introduced. One of the first analysis in this Doctoral Thesis studies the time difference between peak points of the heart beats in the ECG and the ICG: the RC segment. This RC segment is a measure of the time delay between electrical and mechanical activity of the heart. The relationship of the RC segment with blood pressure and heart interval is analyzed. The concordance of beat durations of both the electrocardiogram and the impedance cardiogram is one of the key results to develop new artefact detection algorithms and the RC could also have an impact in describing the hemodynamics of a patient. Time-frequency distributions (TFDs) are also used to characterize how the frequency content in impedance cardiography signals change with time. Since TFDs are calculated using concrete kernels, a new method to select the best kernel by using synthetic signals is presented. Optimized TFDs of ICG signals are then calculated to extract severa! features which are used to discriminate between different anesthesia states in patients undergoing surgery. TFD-derived features are also used to describe the whole surgical operations. Relationships between TFD-derived features are analyzed and prediction models for cardiac output are designed. These prediction models prove that the TFD-derived features are related to the patients' cardiac output. Finally, a validation study for the qCO monitor is presented. The qCO monitor has been designed using sorne of the techniques which are consequence of this Doctoral Thesis. The main outputs of this work have been protected with a patent which has already been filed. As a conclusion, this Doctoral Thesis has produced a considerable amount of clinical data and a variety of analysis and processing techniques of impedance cardiography signals which have been included into commercial medical devices already available on the market.El gasto cardíaco (GC) define el flujo de sangre que llega desde el corazón a los distintos órganos del cuerpo y es, por tanto, un determinante primario del transporte global de oxígeno. Se ha medido tradicionalmente usando métodos invasivos cuyos riesgos excedían en ocasiones las ventajas de su monitorización. En este contexto, la minimización del riesgo de la monitorización del gasto cardíaco en nuevas tecnologías no invasivas podría traducirse en mayores ventajas para médicos, hospitales y pacientes: facilidad de uso, disponibilidad del equipamiento y menor tiempo de recuperación y mejores resultados en el paciente. La impedancio-cardiografía o cardiografía de impedancia (ICG} es una prometedora tecnología no invasiva para la monitorización del gasto cardíaco. Sin embargo, la información disponible sobre las señales de ICG es más escasa que otras señales fisiológicas como el electrocardiograma (ECG). La presente Tesis Doctoral contribuye al desarrollo de técnicas de tratamiento de señal de ICG para así crear un monitor hemodinámico innovador. En primer lugar, se proporciona una extensa revisión bibliográfica sobre los aspectos básicos del contexto clínico en el que se utiliza la monitorización del gasto cardíaco así como sobre el estado del arte de los monitores de gasto cardíaco que existen en el mercado. Esta Tesis Doctoral ha producido una considerable cantidad de datos clínicos que también se explican en detalle. Dichos datos clínicos también son útiles para complementar las explicaciones teóricas de los índices de paciente de variabilidad cardíaca y el flujo y la presión sanguíneos. Además, se presenta un nuevo método de creación de señales sintéticas biomédicas con características de tiempo-frecuencia conocidas. Uno de los primeros análisis de esta Tesis Doctoral estudia la diferencia temporal entre los picos de los latidos cardíacos del ECG y del ICG: el segmento RC. Este segmento RC es una medida del retardo temporal entre la actividad eléctrica y mecánica del corazón. Se analiza la relación del segmento RC con la presión arterial y el intervalo cardíaco. La concordancia entre la duración de los latidos del ECG y del ICG es uno de los resultados claves para desarrollar nuevos algoritmos de detección de artefactos y el segmento RC también podría ser relevante en la descripción de la hemodinámica de los pacientes. Las distribuciones de tiempo-frecuencia (TFD, por sus siglas en inglés) se utilizan para caracterizar cómo el contenido de las señales de impedancia cardiográfica cambia con el tiempo. Dado que las TFDs deben calcularse usando núcleos (kernels, en inglés) concretos, se presenta un nuevo método para seleccionar el mejor núcleo mediante el uso de señales sintéticas. Las TFDs de ICG optimizadas se calculan para extraer distintas características que son usadas para discriminar entre los diferentes estados de anestesia en pacientes sometidos a procesos quirúrgicos. Las características derivadas de las distribuciones de tiempo-frecuencia también son utilizadas para describir las operaciones quirúrgicas durante toda su extensión temporal. La relación entre dichas características son analizadas y se proponen distintos modelos de predicción para el gasto cardíaco. Estos modelos de predicción demuestran que las características derivadas de las distribuciones tiempo-frecuencia de señales de ICG están relacionadas con el gasto cardíaco de los pacientes. Finalmente, se presenta un estudio de validación del monitor qCO, diseñado con alguna de las técnicas que son consecuencia de esta Tesis Doctoral. Las principales conclusiones de este trabajo han sido protegidas con una patente que ya ha sido registrada. Como conclusión, esta Tesis Doctoral ha producido una considerable cantidad de datos clínicos y una variedad de técnicas de procesado y análisis de señales de cardiografía de impedancia que han sido incluidas en dispositivos biomédicos disponibles en el mercad

    Three-dimensional echocardiography and 2D-3D speckle tracking imaging in chronic pulmonary hypertension. diagnostic accuracy in detecting hemodynamic signs of RV failure

    Get PDF
    Background and objective. Our aim was to compare three-dimensional (3D) and 2D and 3D speckle tracking (2D-STE, 3D-STE) echocardiographic parameters with conventional right ventricular (RV) indexes in patients with chronic pulmonary hypertension (PH), and investigate whether these techniques could result in better correlation with hemodynamic variables indicative of heart failure. Methods. Seventy-three adult patients (mean age, 53±13 years; 44% male) with chronic PH of different etiologies were studied by echocardiography and cardiac catheterization (25 precapillary PH from pulmonary arterial hypertension, 23 obstructive pulmonary heart disease, and 23 postcapillary PH from mitral regurgitation). Thirty healthy subjects (mean age, 54±15 years; 43% male) served as controls. Standard 2D measurements (RV-FAC -fractional area change-, TAPSE -tricuspid annular plane systolic excursion-) and mitral and tricuspid tissue Doppler annular velocities were obtained. RV 3D volumes, and global and regional ejection fraction (3D-RVEF) were determined. RV strains were calculated by 2D-STE and 3D-STE. Results. RV 3D global-free-wall longitudinal strain (3DGFW-RVLS), 2D global-free-wall longitudinal strain (GFW-RVLS), apical-free-wall longitudinal strain (AFW-RVLS), basal-free-wall longitudinal strain (BFW-RVLS), and 3D-RVEF were lower in patients with pre-capillary PH (p<0.0001) and post-capillary PH (p<0.01) compared to controls. 3DGFW-RVLS (HR 4.6, 95% CI 2.79-8.38, p=0.004) and 3D-RVEF (HR 5.3, 95% CI 2.85-9.89, p=0.002) were independent predictors of mortality. ROC curves showed that the thresholds offering an adequate compromise between sensitivity and specificity for detecting hemodynamic signs of RV failure were 39% for 3D-RVEF (AUC 0.89), -17% for 3DGFW-RVLS (AUC 0.88), -18% for GFW-RVLS (AUC 0.88), -16% for AFW-RVLS (AUC 0.85), 16mm for TAPSE (AUC 0.67), and 38% for RV-FAC (AUC 0.62). Conclusions. In chronic PH, 3D, 2D-STE and 3D-STE parameters indicate global and regional RV dysfunction that is associated with RV failure hemodynamics better than conventional echo indices

    Accuracy of right atrial pressure estimation using a multi-parameter approach derived from inferior vena cava semi-automated edge-tracking echocardiography: a pilot study in patients with cardiovascular disorders

    Get PDF
    The echocardiographic estimation of right atrial pressure (RAP) is based on the size and inspiratory collapse of the inferior vena cava (IVC). However, this method has proven to have limits of reliability. The aim of this study is to assess feasibility and accuracy of a new semi-automated approach to estimate RAP. Standard acquired echocardiographic images were processed with a semi-automated technique. Indexes related to the collapsibility of the vessel during inspiration (Caval Index, CI) and new indexes of pulsatility, obtained considering only the stimulation due to either respiration (Respiratory Caval Index, RCI) or heartbeats (Cardiac Caval Index, CCI) were derived. Binary Tree Models (BTM) were then developed to estimate either 3 or 5 RAP classes (BTM3 and BTM5) using indexes estimated by the semi-automated technique. These BTMs were compared with two standard estimation (SE) echocardiographic methods, indicated as A and B, distinguishing among 3 and 5 RAP classes, respectively. Direct RAP measurements obtained during a right heart catheterization (RHC) were used as reference. 62 consecutive \u2018all-comers\u2019 patients that had a RHC were enrolled; 13 patients were excluded for technical reasons. Therefore 49 patients were included in this study (mean age 62.2\ua0\ub1\ua015.2\ua0years, 75.5% pulmonary hypertension, 34.7% severe left ventricular dysfunction and 51% right ventricular dysfunction). The SE methods showed poor accuracy for RAP estimation (method A: misclassification error, ME\ua0=\ua051%, R2\ua0=\ua00.22; method B: ME\ua0=\ua069%, R2\ua0=\ua00.26). Instead, the new semi-automated methods BTM3 and BTM5 have higher accuracy (ME\ua0=\ua014%, R2\ua0=\ua00.47 and ME\ua0=\ua022%, R2\ua0=\ua00.61, respectively). In conclusion, a multi-parametric approach using IVC indexes extracted by the semi-automated approach is a promising tool for a more accurate estimation of RAP

    Phenotyping the right ventricle in pulmonary hypertension

    Get PDF
    Pulmonary arterial hypertension (PAH) is a disease in which the lumen of small pulmonary arteries is narrowed because of vasoconstriction, hyperproliferation, inflammation and remodeling of smooth muscle cells and endothelial cells. This leads to an increase in resistance of the pulmonary vascular bed and an therefore an increase in pulmonary artery pressures. As a result the load on the right ventricle (RV) drastically increases, with a subsequent rise in RV wall stress. The RV will initially decrease this wall stress via increasing its wall thickness through hypertrophy and enhancing its contractility. Current PAH-medication decreases the pulmonary vascular resistance (PVR) and therefore reduce the RV afterload, but seldom normalizes it. As a result, the transition of RV adaptation towards RV failure, characterized by RV dilatation and decreased cardiac output, will be inevitable. To date, lung transplantation is the only cure for PAH-patients. To provide timely referral to a transplantation center, it is of utmost importance to identify ‘adapted’ PAH-patients who are prone to develop RV failure. To do so, key players in the transition from RV adaptation towards RV failure have to be identified. In this thesis, we aimed to further identify factors playing a role in RV adaptation and RV failure by comparing different phenotypes of PAH patients. Secondly, we evaluated the use of RV imaging during follow-up in PAH

    Contemporary Review of Hemodynamic Monitoring in the Critical Care Setting

    Get PDF
    Hemodynamic assessment remains the most valuable adjunct to physical examination and laboratory assessment in the diagnosis and management of shock. Through the years, multiple modalities to measure and trend hemodynamic indices have evolved with varying degrees of invasiveness. Pulmonary artery catheter (PAC) has long been considered the gold standard of hemodynamic assessment in critically ill patients and in recent years has been shown to improve clinical outcomes among patients in cardiogenic shock. The invasive nature of PAC is often cited as its major limitation and has encouraged development of less invasive technologies. In this review, the authors summarize the literature on the mechanism and validation of several minimally invasive and noninvasive modalities available in the contemporary intensive care unit. They also provide an update on the use of focused bedside echocardiography
    • …
    corecore