6,562 research outputs found
VLSI Circuits for adaptive digital beamforming in ultrasound imaging
Cataloged from PDF version of article.For phased-array ultrasound imaging, alternative
beamforming techniques and their VLSI circuits are studied
to form a fully digital receive frontad hardware. In order
to increase the timiig accuracy in beamforming, a computationally
efficient interpolation scheme to increase the sampling
rate is examined. For adaptive beamforming, a phase aberration
correction method with very low computational complexity is
described. Image quality performance of the method is examined
by processing the non-aberrated and aberrated phased-array
experimental data sets of an ultrasound resolution phantom. A
digital beamforming scheme based on receive focusing at the
raster focal points is examined. The sector images of the resolution
phantom, reconstructed from the phased-array experimental
data by beamforming at the radial and raster focal points, are
presented for comparison of the image resolution performances
of the two beamforming schemes. VLSI circuits and their implementations
for the proposed techniques are presented
A versatile nondestructive evaluation imaging workstation
Ultrasonic C-scan and eddy current imaging systems are of the pointwise type evaluation systems that rely on a mechanical scanner to physically maneuver a probe relative to the specimen point by point in order to acquire data and generate images. Since the ultrasonic C-scan and eddy current imaging systems are based on the same mechanical scanning mechanisms, the two systems can be combined using the same PC platform with a common mechanical manipulation subsystem and integrated data acquisition software. Based on this concept, we have developed an IBM PC-based combined ultrasonic C-scan and eddy current imaging system. The system is modularized and provides capacity for future hardware and software expansions. Advantages associated with the combined system are: (1) eliminated duplication of the computer and mechanical hardware, (2) unified data acquisition, processing and storage software, (3) reduced setup time for repetitious ultrasonic and eddy current scans, and (4) improved system efficiency. The concept can be adapted to many engineering systems by integrating related PC-based instruments into one multipurpose workstation such as dispensing, machining, packaging, sorting, and other industrial applications
Method and Apparatus for Controlling Acoustic Signal Bandwidth in an Ultrasonic Diagnostic Imaging System
An ultrasonic imaging system includes a receive beam former that generates analog receive signals and a scan converter. A receive signal processing path interconnects the receive beamformer and the scan converter, and this processing path includes both an A/D converter characterized by a selectable sampling rate and at least one filter characterized by at least one filter parameter. The filter parameter is selected as a function of the sampling rate to provide enhanced image quality
Integrated Electronics for Wireless Imaging Microsystems with CMUT Arrays
Integration of transducer arrays with interface electronics in the form of single-chip CMUT-on-CMOS has emerged into the field of medical ultrasound imaging
and is transforming this field. It has already been used in several commercial products such as handheld full-body imagers and it is being implemented by commercial and academic groups for Intravascular Ultrasound and Intracardiac Echocardiography. However, large attenuation of ultrasonic waves transmitted through
the skull has prevented ultrasound imaging of the brain. This research is a prime
step toward implantable wireless microsystems that use ultrasound to image the
brain by bypassing the skull. These microsystems offer autonomous scanning
(beam steering and focusing) of the brain and transferring data out of the brain for
further processing and image reconstruction.
The objective of the presented research is to develop building blocks of an integrated electronics architecture for CMUT based wireless ultrasound imaging systems while providing a fundamental study on interfacing CMUT arrays with their
associated integrated electronics in terms of electrical power transfer and acoustic
reflection which would potentially lead to more efficient and high-performance
systems.
A fully wireless architecture for ultrasound imaging is demonstrated for the
first time. An on-chip programmable transmit (TX) beamformer enables phased
array focusing and steering of ultrasound waves in the transmit mode while its
on-chip bandpass noise shaping digitizer followed by an ultra-wideband (UWB)
uplink transmitter minimizes the effect of path loss on the transmitted image data
out of the brain. A single-chip application-specific integrated circuit (ASIC) is de-
signed to realize the wireless architecture and interface with array elements, each
of which includes a transceiver (TRX) front-end with a high-voltage (HV) pulser,
a high-voltage T/R switch, and a low-noise amplifier (LNA). Novel design techniques are implemented in the system to enhance the performance of its building
blocks.
Apart from imaging capability, the implantable wireless microsystems can include a pressure sensing readout to measure intracranial pressure. To do so, a
power-efficient readout for pressure sensing is presented. It uses pseudo-pseudo
differential readout topology to cut down the static power consumption of the sensor for further power savings in wireless microsystems.
In addition, the effect of matching and electrical termination on CMUT array
elements is explored leading to new interface structures to improve bandwidth
and sensitivity of CMUT arrays in different operation regions. Comprehensive
analysis, modeling, and simulation methodologies are presented for further investigation.Ph.D
Design, analysis and evaluation of sigma-delta based beamformers for medical ultrasound imaging applications
The inherent analogue nature of medical ultrasound signals in conjunction with the abundant merits provided by digital image acquisition, together with the increasing use of relatively simple front-end circuitries, have created considerable demand for single-bit beamformers in digital ultrasound imaging systems. Furthermore, the increasing need to design lightweight ultrasound systems with low power consumption and low noise, provide ample justification for development and innovation in the use of single-bit beamformers in ultrasound imaging systems. The overall aim of this research program is to investigate, establish, develop and confirm through a combination of theoretical analysis and detailed simulations, that utilize raw phantom data sets, suitable techniques for the design of simple-to-implement hardware efficient digital ultrasound beamformers to address the requirements for 3D scanners with large channel counts, as well as portable and lightweight ultrasound scanners for point-of-care applications and intravascular imaging systems.
In addition, the stability boundaries of higher-order High-Pass (HP) and Band-Pass (BP) Σ−Δ modulators for single- and dual- sinusoidal inputs are determined using quasi-linear modeling together with the describing-function method, to more accurately model the modulator quantizer. The theoretical results are shown to be in good agreement with the simulation results for a variety of input amplitudes, bandwidths, and modulator orders. The proposed mathematical models of the quantizer will immensely help speed up the design of higher order HP and BP Σ−Δ modulators to be applicable for digital ultrasound beamformers.
Finally, a user friendly design and performance evaluation tool for LP, BP and HP modulators is developed. This toolbox, which uses various design methodologies and covers an assortment of modulators topologies, is intended to accelerate the design process and evaluation of modulators. This design tool is further developed to enable the design, analysis and evaluation of beamformer structures including the noise analyses of the final B-scan images. Thus, this tool will allow researchers and practitioners to design and verify different reconstruction filters and analyze the results directly on the B-scan ultrasound images thereby saving considerable time and effort
A 3-D High-Frequency Array Based 16 Channel Photoacoustic Microscopy System for In Vivo Micro-Vascular Imaging
This paper discusses the design of a novel photoacoustic microscopy imaging system with promise for studying the structure of tissue microvasculature for applications in visualizing angiogenesis. A new 16 channel analog and digital high-frequency array based photoacoustic microscopy system (PAM) was developed using an Nd: YLF pumped tunable dye laser, a 30 MHz piezo composite linear array transducer, and a custom multichannel receiver electronics system. Using offline delay and sum beam- forming and beamsteering, phantom images were obtained from a 6 µm carbon fiber in water at a depth of 8 mm. The measured -6 dB lateral and axial spatial resolution of the system was 100 ± 5 µm and 45 ± 5 µm, respectively. The dynamic focusing capability of the system was demonstrated by imaging a composite carbon fiber matrix through a 12.5 mm imaging depth. Next, 2-D in vivo images were formed of vessels around 100 µm in diameter in the human hand. Three-dimensional in vivo images were also formed of micro-vessels 3 mm below the surface of the skin in two Sprague Dawley rats
Front-end receiver for miniaturised ultrasound imaging
Point of care ultrasonography has been the focus of extensive research over the past few decades. Miniaturised, wireless systems have been envisaged for new application areas, such as capsule endoscopy, implantable ultrasound and wearable ultrasound. The hardware constraints of such small-scale systems are severe, and tradeoffs between power consumption, size, data bandwidth and cost must be carefully balanced. To address these challenges, two synthetic aperture receiver architectures are proposed and compared. The architectures target highly miniaturised, low cost, B-mode ultrasound imaging systems. The first architecture utilises quadrature (I/Q) sampling to minimise the signal bandwidth and computational load. Synthetic aperture beamforming is carried out using a single-channel, pipelined protocol in order to minimise system complexity and power consumption. A digital beamformer dynamically apodises and focuses the data by interpolating and applying complex phase rotations to the I/Q samples. The beamformer is implemented on a Spartan-6 FPGA and consumes 296mW for a frame rate of 7Hz. The second architecture employs compressive sensing within the finite rate of innovation (FRI) framework to further reduce the data bandwidth. Signals are sampled below the Nyquist frequency, and then transmitted to a digital back-end processor, which reconstructs I/Q components non-linearly, and then carries out synthetic aperture beamforming. Both architectures were tested in hardware using a single-channel analogue front-end (AFE) that was designed and fabricated in AMS 0.35μm CMOS. The AFE demodulates RF ultrasound signals sequentially into I/Q components, and comprises a low-noise preamplifier, mixer, programmable gain amplifier (PGA) and lowpass filter. A variable gain low noise preamplifier topology is used to enable quasi-exponential time-gain control (TGC). The PGA enables digital selection of three gain values (15dB, 22dB and 25.5dB). The bandwidth of the lowpass filter is also selectable between 1.85MHz, 510kHz and 195kHz to allow for testing of both architectural frameworks. The entire AFE consumes 7.8 mW and occupies an area of 1.5×1.5 mm. In addition to the AFE, this thesis also presents the design of a pseudodifferential, log-domain multiplier-filter or “multer” which demodulates low-RF signals in the current-domain. This circuit targets high impedance transducers such as capacitive micromachined ultrasound transducers (CMUTs) and offers a 20dB improvement in dynamic range over the voltage-mode AFE. The bandwidth is also electronically tunable. The circuit was implemented in 0.35μm BiCMOS and was simulated in Cadence; however, no fabrication results were obtained for this circuit. B-mode images were obtained for both architectures. The quadrature SAB method yields a higher image SNR and 9% lower root mean squared error with respect to the RF-beamformed reference image than the compressive SAB method. Thus, while both architectures achieve a significant reduction in sampling rate, system complexity and area, the quadrature SAB method achieves better image quality. Future work may involve the addition of multiple receiver channels and the development of an integrated system-on-chip.Open Acces
Recommended from our members
Extraction of anthropological data with ultrasound
This thesis was submitted for the degree of Doctor of Philosophy and was awarded by Brunel University.Human body scanners used to extract anthropological data have a significant drawback, the
subject is required to undress or wear tight fitting clothing. This thesis demonstrates an
ultrasonic based alternative to the current optical systems, that can potentially operate on a fully
clothed subject. To validate the concept several experiments were performed to determine the
acoustic properties of multiple garments. The results indicated that such an approach was
possible.
Beamforming is introduced as a method by which the ultrasonic scanning area can be increased,
the concept is thoroughly studied and a clear theoretical analysis is performed. Additionally,
Matlab has been used to demonstrate graphically, the results of such analysis, providing an
invaluable tool during the simulation, experimental and results stages of the thesis.
To evaluate beamfoming as a composite part of ultrasonic body imaging, a hardware solution
was necessary. During the concept phase, both FPGA and digital signal processors were
evaluated to determine their suitability for the role. An FPGA approach was finally chosen,
which allows highly parallel operation, essential to the high acquisition speeds required by some
beamforming methodologies. In addition, analogue circuitry was also designed to provide an
interface with the ultrasonic transducers, which, included variable gain amplifiers, charge
amplifiers and signal conditioning. Finally, a digital acquisition card was used to transfer data
between the FPGA and a desktop computer, on which, the sampled data was processed and
displayed in a coherent graphical manner.
The beamforming results clearly demonstrate that imaging multiple layers in air, with
ultrasound, is a viable technique for anthroplogical data collection. Furthermore, a wavelet
based method of improving the axial resolution is also proposed and demonstrated
- …