182 research outputs found

    Novel Muscle Monitoring by Radiomyography(RMG) and Application to Hand Gesture Recognition

    Full text link
    Conventional electromyography (EMG) measures the continuous neural activity during muscle contraction, but lacks explicit quantification of the actual contraction. Mechanomyography (MMG) and accelerometers only measure body surface motion, while ultrasound, CT-scan and MRI are restricted to in-clinic snapshots. Here we propose a novel radiomyography (RMG) for continuous muscle actuation sensing that can be wearable and touchless, capturing both superficial and deep muscle groups. We verified RMG experimentally by a forearm wearable sensor for detailed hand gesture recognition. We first converted the radio sensing outputs to the time-frequency spectrogram, and then employed the vision transformer (ViT) deep learning network as the classification model, which can recognize 23 gestures with an average accuracy up to 99% on 8 subjects. By transfer learning, high adaptivity to user difference and sensor variation were achieved at an average accuracy up to 97%. We further demonstrated RMG to monitor eye and leg muscles and achieved high accuracy for eye movement and body postures tracking. RMG can be used with synchronous EMG to derive stimulation-actuation waveforms for many future applications in kinesiology, physiotherapy, rehabilitation, and human-machine interface

    Multikernel convolutional neural network for sEMG based hand gesture classification

    Get PDF
    openIl riconoscimento dei gesti della mano è un argomento ampiamente discusso in letteratura, dove vengono analizzate diverse tecniche sia in termini di tipi di segnale in ingresso che di algoritmi. Tra i più utilizzati ci sono i segnali elettromiografici (sEMG), già ampiamente sfruttati nelle applicazioni di interazione uomo-macchina (HMI). Determinare come decodificare le informazioni contenute nei segnali EMG in modo robusto e accurato è un problema chiave per il quale è urgente trovare una soluzione. Recentemente, molti incarichi di riconoscimento dei pattern EMG sono stati affrontati utilizzando metodi di deep learning. Nonostante le elevate prestazioni di questi ultimi, le loro capacità di generalizzazione sono spesso limitate dall'elevata eterogeneità tra i soggetti, l'impedenza cutanea, il posizionamento dei sensori, ecc. Inoltre, poiché questo progetto è focalizzato sull'applicazione in tempo reale di protesi, ci sono maggiori vincoli sui tempi di risposta del sistema che riducono la complessità dei modelli. In questa tesi è stata testata una rete neurale convoluzionale multi-kernel su diversi dataset pubblici per verificare la sua generalizzabilità. Inoltre, è stata analizzata la capacità del modello di superare i limiti inter-soggetto e inter-sessione in giorni diversi, preservando i vincoli legati a un sistema embedded. I risultati confermano le difficoltà incontrate nell'estrazione di informazioni dai segnali emg; tuttavia, dimostrano la possibilità di ottenere buone prestazioni per un uso robusto di mani prostetiche. Inoltre, è possibile ottenere prestazioni migliori personalizzando il modello con tecniche di transfer learning e di adattamento al dominio.Hand gesture recognition is a widely discussed topic in the literature, where different techniques are analyzed in terms of both input signal types and algorithms. Among the most widely used are electromyographic signals (sEMG), which are already widely exploited in human-computer interaction (HMI) applications. Determining how to decode the information contained in EMG signals robustly and accurately is a key problem for which a solution is urgently needed. Recently, many EMG pattern recognition tasks have been addressed using deep learning methods. Despite their high performance, their generalization capabilities are often limited by high heterogeneity among subjects, skin impedance, sensor placement, etc. In addition, because this project is focused on the real-time application of prostheses, there are greater constraints on the system response times that reduce the complexity of the models. In this thesis, a multi-kernel convolutional neural network was tested on several public datasets to verify its generalizability. In addition, the model's ability to overcome inter-subject and inter-session constraints on different days while preserving the constraints associated with an embedded system was analyzed. The results confirm the difficulties encountered in extracting information from emg signals; however, they demonstrate the possibility of achieving good performance for robust use of prosthetic hands. In addition, better performance can be achieved by customizing the model with transfer learning and domain-adaptationtechniques

    Multimodal human hand motion sensing and analysis - a review

    Get PDF

    Advances in Integrated Circuits and Systems for Wearable Biomedical Electrical Impedance Tomography

    Get PDF
    Electrical impedance tomography (EIT) is an impedance mapping technique that can be used to image the inner impedance distribution of the subject under test. It is non-invasive, inexpensive and radiation-free, while at the same time it can facilitate long-term and real-time dynamic monitoring. Thus, EIT lends itself particularly well to the development of a bio-signal monitoring/imaging system in the form of wearable technology. This work focuses on EIT system hardware advancement using complementary metal oxide semiconductor (CMOS) technology. It presents the design and testing of application specific integrated circuit (ASIC) and their successful use in two bio-medical applications, namely, neonatal lung function monitoring and human-machine interface (HMI) for prosthetic hand control. Each year fifteen million babies are born prematurely, and up to 30% suffer from lung disease. Although respiratory support, especially mechanical ventilation, can improve their survival, it also can cause injury to their vulnerable lungs resulting in severe and chronic pulmonary morbidity lasting into adulthood, thus an integrated wearable EIT system for neonatal lung function monitoring is urgently needed. In this work, two wearable belt systems are presented. The first belt features a miniaturized active electrode module built around an analog front-end ASIC which is fabricated with 0.35-µm high-voltage process technology with ±9 V power supplies and occupies a total die area of 3.9 mm². The ASIC offers a high power active current driver capable of up to 6 mAp-p output, and wideband active buffer for EIT recording as well as contact impedance monitoring. The belt has a bandwidth of 500 kHz, and an image frame rate of 107 frame/s. To further improve the system, the active electrode module is integrated into one ASIC. It contains a fully differential current driver, a current feedback instrumentation amplifier (IA), a digital controller and multiplexors with a total die area of 9.6 mm². Compared to the conventional active electrode architecture employed in the first EIT belt, the second belt features a new architecture. It allows programmable flexible electrode current drive and voltage sense patterns under simple digital control. It has intimate connections to the electrodes for the current drive and to the IA for direct differential voltage measurement providing superior common-mode rejection ratio (CMRR) up to 74 dB, and with active gain, the noise level can be reduced by a factor of √3 using the adjacent scan. The second belt has a wider operating bandwidth of 1 MHz and multi-frequency operation. The image frame rate is 122 frame/s, the fastest wearable EIT reported to date. It measures impedance with 98% accuracy and has less than 0.5 Ω and 1° variation across all channels. In addition the ASIC facilitates several other functionalities to provide supplementary clinical information at the bedside. With the advancement of technology and the ever-increasing fusion of computer and machine into daily life, a seamless HMI system that can recognize hand gestures and motions and allow the control of robotic machines or prostheses to perform dexterous tasks, is a target of research. Originally developed as an imaging technique, EIT can be used with a machine learning technique to track bones and muscles movement towards understanding the human user’s intentions and ultimately controlling prosthetic hand applications. For this application, an analog front-end ASIC is designed using 0.35-µm standard process technology with ±1.65 V power supplies. It comprises a current driver capable of differential drive and a low noise (9μVrms) IA with a CMRR of 80 dB. The function modules occupy an area of 0.07 mm². Using the ASIC, a complete HMI system based on the EIT principle for hand prosthesis control has been presented, and the user’s forearm inner bio-impedance redistribution is assessed. Using artificial neural networks, bio-impedance redistribution can be learned so as to recognise the user’s intention in real-time for prosthesis operation. In this work, eleven hand motions are designed for prosthesis operation. Experiments with five subjects show that the system can achieve an overall recognition accuracy of 95.8%
    • …
    corecore