1,572 research outputs found

    Perturbation Analysis for Robust Damage Detection with Application to Multifunctional Aircraft Structures

    Get PDF
    The most widely known form of multifunctional aircraft structure is smart structures for structural health monitoring (SHM). The aim is to provide automated systems whose purposes are to identify and to characterize possible damage within structures by using a network of actuators and sensors. Unfortunately, environmental and operational variability render many of the proposed damage detection methods difficult to successfully be applied. In this paper, an original robust damage detection approach using output-only vibration data is proposed. It is based on independent component analysis and matrix perturbation analysis, where an analytical threshold is proposed to get rid of statistical assumptions usually performed in damage detection approach. The effectiveness of the proposed SHM method is demonstrated numerically using finite element simulations and experimentally through a conformal load-bearing antenna structure and composite plates instrumented with piezoelectric ceramic materials.FUI MSIE (Pole Astech

    On the development of a cybernetic prosthetic hand

    Get PDF
    The human hand is the end organ of the upper limb, which in humans serves the important function of prehension, as well as being an important organ for sensation and communication. It is a marvellous example of how a complex mechanism can be implemented, capable of realizing very complex and useful tasks using a very effective combination of mechanisms, sensing, actuation and control functions. In this thesis, the road towards the realization of a cybernetic hand has been presented. After a detailed analysis of the model, the human hand, a deep review of the state of the art of artificial hands has been carried out. In particular, the performance of prosthetic hands used in clinical practice has been compared with the research prototypes, both for prosthetic and for robotic applications. By following a biomechatronic approach, i.e. by comparing the characteristics of these hands with the natural model, the human hand, the limitations of current artificial devices will be put in evidence, thus outlining the design goals for a new cybernetic device. Three hand prototypes with a high number of degrees of freedom have been realized and tested: the first one uses microactuators embedded inside the structure of the fingers, and the second and third prototypes exploit the concept of microactuation in order to increase the dexterity of the hand while maintaining the simplicity for the control. In particular, a framework for the definition and realization of the closed-loop electromyographic control of these devices has been presented and implemented. The results were quite promising, putting in evidence that, in the future, there could be two different approaches for the realization of artificial devices. On one side there could be the EMG-controlled hands, with compliant fingers but only one active degree of freedom. On the other side, more performing artificial hands could be directly interfaced with the peripheral nervous system, thus establishing a bi-directional communication with the human brain

    Design and Control of a Hand Prosthesis

    Get PDF
    Práce předkládá metody a výsledky návrhu, výroby a výzkumu pětiprsté protézy ruky. Inspirace jdoucí z přírody a z toho vyvozený princip použitého mechanizmu je uveden. Základní koncept řídícího schéma založeného na procesingu a ohodnocení EMG je navrhnut a implementován. Části senzorického systému protézy jsou navrhnuty a zahrnuty do rídícího algoritmu a shématu. Velké množství inovací a návrhů pro budoucí práce a výzkum jsou prezentovány, stejně tak komplexní analýza a diskuse dosažených a možných budoucích výsledků.The text shows idea flow, methods and results in design, manufacture and research of five--fingered prosthetic hand. The inspiration of the nature and mechanical principle elicited is presented. Fundamental control scheme based on processing and evaluation of EMG is designed and implemented. The segments of sensory system are designed and involved into the overall controll scheme idea. Large innovations and suggestions for future work and research are given with complex discussion through reached and hopefully future results.

    A Robot Operating System (ROS) based humanoid robot control

    Get PDF
    This thesis presents adapting techniques required to enhance the capability of a commercially available robot, namely, Robotis Bioloid Premium Humanoid Robot (BPHR). BeagleBone Black (BBB), the decision-making and implementing (intelligence providing) component, with multifunctional capabilities is used in this research. Robot operating System (ROS) and its libraries, as well as Python Script and its libraries have been developed and incorporated into the BBB. This fortified BBB intelligence providing component is then transplanted into the structure of the Robotis Bioloid humanoid robot, after removing the latter’s original decision-making and implementing component (controller). Thus, this study revitalizes the Bioloid humanoid robot by converting it into a humanoid robot with multiple features that can be inherited using ROS. This is a first of its kind approach wherein ROS is used as the development framework in conjunction with the main BBB controller and the software impregnated with Python libraries is used to integrate robotic functions. A full ROS computation is developed and a high level Application Programming Interface (API) usable by software utilizing ROS services is also developed. In this revised two-legged-humanoid robot, USB2Dynamixel connector is used to operate the Dynamixel AX-12A actuators through the Wi-Fi interface of the fortified BBB. An accelerometer sensor supports balancing of the robot, and updates data to the BBB periodically. An Infrared (IR) sensor is used to detect obstacles. This dynamic model is used to actuate the motors mounted on the robot leg thereby resulting in a swing-stance period of the legs for a stable forward movement of the robot. The maximum walking speed of the robot is 0.5 feet/second, beyond this limit the robot becomes unstable. The angle at which the robot leans is governed by the feedback from the accelerometer sensor, which is 20 degrees. If the robot tilts beyond a specific degree, then it would come back to its standstill position and stop further movement. When the robot moves forward, the IR sensors sense obstacles in front of the robot. If an obstacle is detected within 35 cm, then the robot stops moving further. Implementation of ROS on top of the BBB (by replacing CM530 controller with the BBB) and using feedback controls from the accelerometer and IR sensor to control the two-legged robotic movement are the novelties of this work

    Advances in Bio-Inspired Robots

    Get PDF
    This book covers three major topics, specifically Biomimetic Robot Design, Mechanical System Design from Bio-Inspiration, and Bio-Inspired Analysis on A Mechanical System. The Biomimetic Robot Design part introduces research on flexible jumping robots, snake robots, and small flying robots, while the Mechanical System Design from Bio-Inspiration part introduces Bioinspired Divide-and-Conquer Design Methodology, Modular Cable-Driven Human-Like Robotic Arm andWall-Climbing Robot. Finally, in the Bio-Inspired Analysis on A Mechanical System part, research contents on the control strategy of Surgical Assistant Robot, modeling of Underwater Thruster, and optimization of Humanoid Robot are introduced

    SENSING MECHANISM AND APPLICATION OF MECHANICAL STRAIN SENSOR: A MINI-REVIEW

    Get PDF
    This study reviews the potential of flexible strain sensors based on nanomaterials such as carbon nanotubes (CNTs), graphene, and metal nanowires (NWs). These nanomaterials have excellent flexibility, conductivity, and mechanical properties, which enable them to be integrated into clothing or attached to the skin for the real-time monitoring of various activities. However, the main challenge is balancing high stretchability and sensitivity. This paper explains the basic concept of strain sensors that can convert mechanical deformation into electrical signals. Moreover, this paper focuses on simple, flexible, and stretchable resistive and capacitive sensors. It also discusses the important factors in choosing materials and fabrication methods, emphasizing the crucial role of suitable polymers in high-performance strain sensing. This study reviews the fabrication processes, mechanisms, performance, and applications of stretchable strain sensors in detail. It analyzes key aspects, such as sensitivity, stretchability, linearity, response time, and durability. This review provides useful insights into the current status and prospects of stretchable strain sensors in wearable technology and human–machine interfaces
    corecore