294 research outputs found

    Biosignal‐based human–machine interfaces for assistance and rehabilitation : a survey

    Get PDF
    As a definition, Human–Machine Interface (HMI) enables a person to interact with a device. Starting from elementary equipment, the recent development of novel techniques and unobtrusive devices for biosignals monitoring paved the way for a new class of HMIs, which take such biosignals as inputs to control various applications. The current survey aims to review the large literature of the last two decades regarding biosignal‐based HMIs for assistance and rehabilitation to outline state‐of‐the‐art and identify emerging technologies and potential future research trends. PubMed and other databases were surveyed by using specific keywords. The found studies were further screened in three levels (title, abstract, full‐text), and eventually, 144 journal papers and 37 conference papers were included. Four macrocategories were considered to classify the different biosignals used for HMI control: biopotential, muscle mechanical motion, body motion, and their combinations (hybrid systems). The HMIs were also classified according to their target application by considering six categories: prosthetic control, robotic control, virtual reality control, gesture recognition, communication, and smart environment control. An ever‐growing number of publications has been observed over the last years. Most of the studies (about 67%) pertain to the assistive field, while 20% relate to rehabilitation and 13% to assistance and rehabilitation. A moderate increase can be observed in studies focusing on robotic control, prosthetic control, and gesture recognition in the last decade. In contrast, studies on the other targets experienced only a small increase. Biopotentials are no longer the leading control signals, and the use of muscle mechanical motion signals has experienced a considerable rise, especially in prosthetic control. Hybrid technologies are promising, as they could lead to higher performances. However, they also increase HMIs’ complex-ity, so their usefulness should be carefully evaluated for the specific application

    Shoulder muscle activation pattern recognition based on sEMG and machine learning algorithms

    Get PDF
    BACKGROUND AND OBJECTIVE: Surface electromyography (sEMG) has been used for robotic rehabilitation engineering for volitional control of hand prostheses or elbow exoskeleton, however, using sEMG for volitional control of an upper limb exoskeleton has not been perfectly developed. The long-term goal of our study is to process shoulder muscle bio-electrical signals for rehabilitative robotic assistive device motion control. The purposes of this study included: 1) to test the feasibility of machine learning algorithms in shoulder motion pattern recognition using sEMG signals from shoulder and upper limb muscles, 2) to investigate the influence of motion speed, individual variability, EMG recording device, and the amount of EMG datasets on the shoulder motion pattern recognition accuracy. METHODS: A novel convolutional neural network (CNN) structure was constructed to process EMG signals from 12 muscles for the pattern recognition of upper arm motions including resting, drinking, backward-forward motion, and abduction motion. The accuracy of the CNN models for pattern recognition under different motion speeds, among individuals, and by EMG recording devices was statistically analyzed using ANOVA, GLM Univariate analysis, and Chi-square tests. The influence of EMG dataset number used for CNN model training on recognition accuracy was studied by gradually increasing dataset number until the highest accuracy was obtained. RESULTS: Results showed that the accuracy of the normal speed CNN model in motion pattern recognition was 97.57% for normal speed motions and 97.07% for fast speed motions. The accuracy of the cross-subjects CNN model in motion pattern recognition was 79.64%. The accuracy of the cross-device CNN model in motion pattern recognition was 88.93% for normal speed motion and 80.87% for mixed speed. There was a statistical difference in pattern recognition accuracy between different CNN models. CONCLUSION: The EMG signals of shoulder and upper arm muscles from the upper limb motions can be processed using CNN algorithms to recognize the identical motions of the upper limb including drinking, forward/backward, abduction, and resting. A simple CNN model trained by EMG datasets of a designated motion speed accurately detected the motion patterns of the same motion speed, yielding the highest accuracy compared with other mixed CNN models for various speeds of motion pattern recognition. Increase of the number of EMG datasets for CNN model training improved the pattern recognition accuracy

    Robotics rehabilitation of the elbow based on surface electromyography signals

    Get PDF
    Physical rehabilitation based on robotic systems has the potential to cover the patient’s need of improvement of upper extremity functionalities. In this article, the state of the art of resistant and assistive upper limb exoskeleton robots and their control are thoroughly investigated. Afterward, a single-degree-of-freedom exoskeleton matching the elbow–forearm has been advanced to grant a valid rehabilitation therapy for persons with physical disability of upper limb motion. The authors have focused on the control system based on the use of electromyography signals as an input to drive the joint movement and manage the robotics arm. The correlation analysis between surface electromyography signal and the force exerted by the subject was studied in objects’ grasping tests with the purpose of validating the methodology. The authors developed an innovative surface electromyography force–based active control that adjusts the force exerted by the device during rehabilitation. The control was validated by an experimental campaign on healthy subjects simulating disease on an arm, with positive results that confirm the proposed solution and that open the way to future researches

    Development of an EMG-based Muscle Health Model for Elbow Trauma Patients

    Get PDF
    Musculoskeletal (MSK) conditions are a leading cause of pain and disability worldwide. Rehabilitation is critical for recovery from these conditions and for the prevention of long-term disability. Robot-assisted therapy has been demonstrated to provide improvements to stroke rehabilitation in terms of efficiency and patient adherence. However, there are no wearable robot-assisted solutions for patients with MSK injuries. One of the limiting factors is the lack of appropriate models that allow the use of biosignals as an interface input. Furthermore, there are no models to discern the health of MSK patients as they progress through their therapy. This thesis describes the design, data collection, analysis, and validation of a novel muscle health model for elbow trauma patients. Surface electromyography (sEMG) data sets were collected from the injured arms of elbow trauma patients performing 10 upper-limb motions. The data were assessed and compared to sEMG data collected from the patients\u27 contralateral healthy limbs. A statistical analysis was conducted to identify trends relating the sEMG signals to muscle health. sEMG-based classification models for muscle health were developed. Relevant sEMG features were identified and combined into feature sets for the classification models. The classifiers were used to distinguish between two levels of health: healthy and injured (50% baseline accuracy rate). Classification models based on individual motions achieved cross-validation accuracies of 48.2--79.6%. Following feature selection and optimization of the models, cross-validation accuracies of up to 82.1% were achieved. This work suggests that there is a potential for implementing an EMG-based model of muscle health in a rehabilitative elbow brace to assess patients recovering from MSK elbow trauma. However, more research is necessary to improve the accuracy and the specificity of the classification models

    Biomechatronics: Harmonizing Mechatronic Systems with Human Beings

    Get PDF
    This eBook provides a comprehensive treatise on modern biomechatronic systems centred around human applications. A particular emphasis is given to exoskeleton designs for assistance and training with advanced interfaces in human-machine interaction. Some of these designs are validated with experimental results which the reader will find very informative as building-blocks for designing such systems. This eBook will be ideally suited to those researching in biomechatronic area with bio-feedback applications or those who are involved in high-end research on manmachine interfaces. This may also serve as a textbook for biomechatronic design at post-graduate level

    Design and development of the sEMG-based exoskeleton strength enhancer for the legs

    Get PDF
    This paper reviews the different exoskeleton designs and presents a working prototype of a surface electromyography (EMG) controlled exoskeleton to enhance the strength of the lower leg. The Computer Aided Design (CAD) model of the exoskeleton is designed,3D printed with respect to the golden ratio of human anthropometry, and tested structurally. The exoskeleton control system is designed on the LabVIEW National Instrument platform and embedded in myRIO. Surface EMG sensors (sEMG) and flex sensors are usedcoherently to create different state filters for the EMG, human body posture and control for the mechanical exoskeleton actuation. The myRIO is used to process sEMG signals and send control signals to the exoskeleton. Thus,the complete exoskeleton system consists of sEMG as primary sensor and flex sensor as a secondary sensor while the whole control system is designed in LabVIEW. FEA simulation and tests show that the exoskeleton is suitable for an average human weight of 62 kg plus excess force with different reactive spring forces. However, due to the mechanical properties of the exoskeleton actuator, it will require an additional liftto provide the rapid reactive impulse force needed to increase biomechanical movement such as squatting up. Finally, with the increasing availability of such assistive devices on the market, the important aspect of ethical, social and legal issues have also emerged and discussed in this paper

    Design and development of the sEMG-based exoskeleton strength enhancer for the legs

    Get PDF
    This paper reviews the different exoskeleton designs and presents a working prototype of a surface electromyography (EMG) controlled exoskeleton to enhance the strength of the lower leg. The Computer Aided Design (CAD) model of the exoskeleton is designed,3D printed with respect to the golden ratio of human anthropometry, and tested structurally. The exoskeleton control system is designed on the LabVIEW National Instrument platform and embedded in myRIO. Surface EMG sensors (sEMG) and flex sensors are usedcoherently to create different state filters for the EMG, human body posture and control for the mechanical exoskeleton actuation. The myRIO is used to process sEMG signals and send control signals to the exoskeleton. Thus,the complete exoskeleton system consists of sEMG as primary sensor and flex sensor as a secondary sensor while the whole control system is designed in LabVIEW. FEA simulation and tests show that the exoskeleton is suitable for an average human weight of 62 kg plus excess force with different reactive spring forces. However, due to the mechanical properties of the exoskeleton actuator, it will require an additional liftto provide the rapid reactive impulse force needed to increase biomechanical movement such as squatting up. Finally, with the increasing availability of such assistive devices on the market, the important aspect of ethical, social and legal issues have also emerged and discussed in this paper
    • 

    corecore