3,118 research outputs found

    LARES-lab: a thermovacuum facility for research and e-learning. Tests of LARES satellite components and small payloads for e-learning

    Get PDF
    LARES, an Italian Space Agency satellite, has been launched successfully in 2012. A small thermovacuum facility has been designed and built specifically for performing tests on the optical components of the satellite. Due to the extremely demanding performances of the optical cube corner reflectors, the space conditions have been simulated using the most up-to-date technology available. In particular Sun, Earth and deep space can be simulated in a ultra high vacuum. It is planned to automate the facility so that it can be operated remotely over the internet. The students during the lectures and the researchers from home will be able to perform thermal tests on specimens by exposing them, for specified amount of time, toward Earth, Sun or deep space. They will collect pressures and temperatures and will input additional thermal power through resistive heaters. The paper will first describe the facility and its capabilities showing the tests performed on LARES satellite components but will focus mainly to the planned upgrades that improve its remote use both for research and e-learning

    Design and realization of a sputter deposition system for the \textit{in situ-} and \textit{in operando-}use in polarized neutron reflectometry experiments

    Full text link
    We report on the realization of a sputter deposition system for the in situ- and in operando-use in polarized neutron reflectometry experiments. Starting with the scientific requirements, which define the general design considerations, the external limitations and boundaries imposed by the available space at a neutron beamline and by the neutron and vacuum compatibility of the used materials, are assessed. The relevant aspects are then accounted for in the realization of our highly mobile deposition system, which was designed with a focus on a quick and simple installation and removability at the beamline. Apart from the general design, the in-vacuum components, the auxiliary equipment and the remote control via a computer, as well as relevant safety aspects are presented in detail.Comment: Submitted for publication in Nuclear Inst. and Methods in Physics Research, A. (1st revised version

    An ultrahigh-vacuum cryostat for simultaneous scanning tunneling microscopy and magneto-transport measurements down to 400mK

    Full text link
    We present the design and calibration measurements of a scanning tunneling microscope setup in a 3He ultrahigh-vacuum cryostat operating at 400 mK with a hold time of 10 days. With 2.70 m in height and 4.70 m free space needed for assembly, the cryostat fits in a one-story lab building. The microscope features optical access, an xy table, in situ tip and sample exchange, and enough contacts to facilitate atomic force microscopy in tuning fork operation and simultaneous magneto-transport measurements on the sample. Hence, it enables scanning tunneling spectroscopy on microstructured samples which are tuned into preselected transport regimes. A superconducting magnet provides a perpendicular field of up to 14 T. The vertical noise of the scanning tunneling microscope amounts to 1 pmrms within a 700 Hz bandwidth. Tunneling spectroscopy using one superconducting electrode revealed an energy resolution of 120 mueV. Data on tip-sample Josephson contacts yield an even smaller feature size of 60 mueV, implying that the system operates close to the physical noise limit.Comment: 12 pages, 11 figure

    Low-temperature, high-resolution magnetic force microscopy using a quartz tuning fork

    Full text link
    We have developed a low temperature, high resolution magnetic force microscope (MFM) using a quartz tuning fork that can operate in a magnetic field. A tuning fork with a spring constant of 1300 N/m mounted with a commercial MFM cantilever tip was used. We have obtained high resolution images of the stray magnetic fields exerted from grains with a spatial resolution of 15 nm and force resolution of 2 pN at 4.2 K. Tuning fork based magnetic force microscopes have the potential to be used at millikelvin temperatures due to their low power dissipation and high force sensitivity.Comment: 3page
    • …
    corecore