652 research outputs found

    An accurate, trimless, high PSRR, low-voltage, CMOS bandgap reference IC

    Get PDF
    Bandgap reference circuits are used in a host of analog, digital, and mixed-signal systems to establish an accurate voltage standard for the entire IC. The accuracy of the bandgap reference voltage under steady-state (dc) and transient (ac) conditions is critical to obtain high system performance. In this work, the impact of process, power-supply, load, and temperature variations and package stresses on the dc and ac accuracy of bandgap reference circuits has been analyzed. Based on this analysis, the a bandgap reference that 1. has high dc accuracy despite process and temperature variations and package stresses, without resorting to expensive trimming or noisy switching schemes, 2. has high dc and ac accuracy despite power-supply variations, without using large off-chip capacitors that increase bill-of-material costs, 3. has high dc and ac accuracy despite load variations, without resorting to error-inducing buffers, 4. is capable of producing a sub-bandgap reference voltage with a low power-supply, to enable it to operate in modern, battery-operated portable applications, 5. utilizes a standard CMOS process, to lower manufacturing costs, and 6. is integrated, to consume less board space has been proposed. The functionality of critical components of the system has been verified through prototypes after which the performance of the complete system has been evaluated by integrating all the individual components on an IC. The proposed CMOS bandgap reference can withstand 5mA of load variations while generating a reference voltage of 890mV that is accurate with respect to temperature to the first order. It exhibits a trimless, dc 3-sigma accuracy performance of 0.84% over a temperature range of -40°C to 125°C and has a worst case ac power-supply ripple rejection (PSRR) performance of 30dB up to 50MHz using 60pF of on-chip capacitance. All the proposed techniques lead to the development of a CMOS bandgap reference that meets the low-cost, high-accuracy demands of state-of-the-art System-on-Chip environments.Ph.D.Committee Chair: Rincon-Mora, Gabriel; Committee Member: Ayazi, Farrokh; Committee Member: Bhatti, Pamela; Committee Member: Leach, W. Marshall; Committee Member: Morley, Thoma

    Utilizing Unconventional CMOS Techniques for Low Voltage Low Power Analog Circuits Design for Biomedical Applications

    Get PDF
    Tato disertační práce se zabývá navržením nízkonapěťových, nízkopříkonových analogových obvodů, které používají nekonvenční techniky CMOS. Lékařská zařízení na bateriové napájení, jako systémy pro dlouhodobý fyziologický monitoring, přenosné systémy, implantovatelné systémy a systémy vhodné na nošení, musí být male a lehké. Kromě toho je nutné, aby byly tyto systémy vybaveny baterií s dlouhou životností. Z tohoto důvodu převládají v biomedicínských aplikacích tohoto typu nízkopříkonové integrované obvody. Nekonvenční techniky jako např. využití transistorů s řízeným substrátem (Bulk-Driven “BD”), s plovoucím hradlem (Floating-Gate “FG”), s kvazi plovoucím hradlem (Quasi-Floating-Gate “QFG”), s řízeným substrátem s plovoucím hradlem (Bulk-Driven Floating-Gate “BD-FG”) a s řízeným substrátem s kvazi plovoucím hradlem (Bulk-Driven Quasi-Floating-Gate “BD-QFG”), se v nedávné době ukázaly jako efektivní prostředek ke zjednodušení obvodového zapojení a ke snížení velikosti napájecího napětí směrem k prahovému napětí u tranzistorů MOS (MOST). V práci jsou podrobně představeny nejdůležitější charakteristiky nekonvenčních technik CMOS. Tyto techniky byly použity pro vytvoření nízko napěťových a nízko výkonových CMOS struktur u některých aktivních prvků, např. Operational Transconductance Amplifier (OTA) založené na BD, FG, QFG, a BD-QFG techniky; Tunable Transconductor založený na BD MOST; Current Conveyor Transconductance Amplifier (CCTA) založený na BD-QFG MOST; Z Copy-Current Controlled-Current Differencing Buffered Amplifier (ZC-CC-CDBA) založený na BD MOST; Winner Take All (WTA) and Loser Take All (LTA) založený na BD MOST; Fully Balanced Four-Terminal Floating Nullor (FBFTFN) založený na BD-QFG technice. Za účelem ověření funkčnosti výše zmíněných struktur, byly tyto struktury použity v několika aplikacích. Výkon navržených aktivních prvků a příkladech aplikací je ověřován prostřednictvím simulačních programů PSpice či Cadence za použití technologie 0.18 m CMOS.This doctoral thesis deals with designing ultra-low-voltage (LV) low-power (LP) analog circuits utilizing the unconventional CMOS techniques. Battery powered medical devices such as; long term physiological monitoring, portable, implantable, and wearable systems need to be small and lightweight. Besides, long life battery is essential need for these devices. Thus, low-power integrated circuits are always paramount in such biomedical applications. Recently, unconventional CMOS techniques i.e. Bulk-Driven (BD), Floating-Gate (FG), Quasi-Floating-Gate (QFG), Bulk-Driven Floating-Gate (BD-FG) and Bulk-Driven Quasi-Floating-Gate (BD-QFG) MOS transistors (MOSTs) have revealed as effective devices to reduce the circuit complexity and push the voltage supply of the circuit towards threshold voltage of the MOST. In this work, the most important features of the unconventional CMOS techniques are discussed in details. These techniques have been utilized to perform ultra-LV LP CMOS structures of several active elements i.e. Operational Transconductance Amplifier (OTA) based on BD, FG, QFG, and BD-QFG techniques; Tunable Transconductor based on BD MOST; Current Conveyor Transconductance Amplifier (CCTA) based on BD-QFG MOST; Z Copy-Current Controlled-Current Differencing Buffered Amplifier (ZC-CC-CDBA) based on BD MOST; Winner Take All (WTA) and Loser Take All (LTA) based on BD MOST; Fully Balanced Four-Terminal Floating Nullor (FBFTFN) based on BD-QFG technique. Moreover, to verify the workability of the proposed structures, they were employed in several applications. The performance of the proposed active elements and their applications were investigated through PSpice or Cadence simulation program using 0.18 m CMOS technology.

    Construction of a laboratory type, convertible excitation argon laser

    Get PDF
    The purpose of this thesis is to describe the construction of a general purpose, convertable [sic] excitation, laboratory type, argon laser. Quartz tubing was used in the final model while attempts to use alumina were made during earlier work. The final model has total optical power output of 230 mw at a discharge current of 29 amperes in the dc excitation mode. Provision was also made to utilize RF or pulsed excitation. The device is built so that several values of optical transmittance are available with a wide range of mirror placement --Abstract, page ii

    CMOS Nonlinear Signal Processing Circuits

    Get PDF

    The Role of Agriculture in South Dakota\u27s Economy : An Approach to Analysis

    Get PDF
    Dependency of the state\u27s economy upon the agricultural sector demands that economic research and public policy with respect to agriculture be based upon a more refined understanding of the magnitude and nature of the relationship between the farm and nonfarm economies. Ideally, the earliest stages of decision-making in government grow out of carefully developed research into the likely outcomes of alternative public policy decisions. At the macroeconomic level, such research requires a firm grasp of the complex chain of events which will occur as a result of changes in policy toward agriculture. At present, this chain of events is only understood in very general terms. Persons familiar with particular segments of the agricultural economy have a sophisticated understanding of production costs associated with particular types of farm enterprises and therefore of their impacts upon the factor markets. Yet, explicit analyses of these impacts are not available. Much less is there a formal compilation of the impacts of major agricultural sectors on the relevant factor markets. A study to provide such analyses would be extremely valuable to researchers who evaluate alternative agricultural policies and study agriculture-related sectors. Such study would in turn be of value to ultimate decision-making bodies which would be provided with broad, yet more refined understanding of the role of agriculture in the South Dakota economy. In short, study of this role is needed to refine the decision-making process with respect to the agricultural economy from the initial research stages to the formal legislative level

    Ultrasound Guided Robot for Human Liver Biopsy using High Intensity Focused Ultrasound for Hemostasis

    Get PDF
    Percutaneous liver biopsy is the gold standard among clinician\u27s tool to diagnose and guide subsequent therapy for liver disease. Ultrasound image guidance is being increasingly used to reduce associated procedural risks but post–biopsy complications still persist. The major and most common complication is hemorrhage, which is highly unpredictable and may sometimes lead to death. Though the risk of mortality is low, it is too high for a diagnostic procedure. Post-biopsy care and additional surgical intervention to arrest hemorrhage make liver biopsy a costly procedure for health care delivery systems. Non-invasive methods to stop bleeding exist like electro–cautery, microwave, lasers, radio frequency, argon–beam, and High Intensity Focused Ultrasound (HIFU). All the methods except HIFU require direct exposure of the needle puncture site for hemostasis. HIFU is an ultrasound modality and uses mechanical sound waves for focused energy delivery. Ultrasound waves are minimally affected by tissue attenuation and focus internal targets without direct exposure. Human error in focusing HIFU renders it unusable for a medical procedure especially when noninvasive. In this project we designed and developed an ultrasound guided prototype robot for accurate HIFU targeting to induce hemostasis. The robotic system performs percutaneous needle biopsy and a 7.5 cm focal length HIFU is fired at the puncture point when the needle tip retracts to the liver surface after sample collection. The robot has 4 degrees of freedom (DOF) for biopsy needle insertion, HIFU positioning, needle angle alignment and US probe image plane orientation. As the needle puncture point is always in the needle path, mechanically constraining the HIFU to focus on the needle reduced the required functionality significantly. Two mini c-arms are designed for needle angle alignment and US probe image plane orientation. This reduced the contact foot print of the robot over the patient providing a greater dexterity for positioning the robot. The robot is validated for HIFU hemostasis by a series of experiments on chicken breasts. HIFU initiated hemorrhage control with robotic biopsy ensures arrest of post-biopsy hemorrhage and decreases patient anxiety, hospital stay, morbidity, time of procedure, and cost. This can also be extended to other organs like kidneys, lungs etc. and has widespread implications such as control of hemorrhage in post-biopsies in patients with reduced ability for hemostasis. This research opens a greater scope for research for automation and design making it a physician friendly tool for eventual clinical use

    Advances in Solid State Circuit Technologies

    Get PDF
    This book brings together contributions from experts in the fields to describe the current status of important topics in solid-state circuit technologies. It consists of 20 chapters which are grouped under the following categories: general information, circuits and devices, materials, and characterization techniques. These chapters have been written by renowned experts in the respective fields making this book valuable to the integrated circuits and materials science communities. It is intended for a diverse readership including electrical engineers and material scientists in the industry and academic institutions. Readers will be able to familiarize themselves with the latest technologies in the various fields

    Evaluation and study of advanced optical contamination, deposition, measurement, and removal techniques

    Get PDF
    A program is described to design, fabricate and install an experimental work chamber assembly (WCA) to provide a wide range of experimental capability. The WCA incorporates several techniques for studying the kinetics of contaminant films and their effect on optical surfaces. It incorporates the capability for depositing both optical and contaminant films on temperature-controlled samples, and for in-situ measurements of the vacuum ultraviolet reflectance. Ellipsometer optics are mounted on the chamber for film thickness determinations, and other features include access ports for radiation sources and instrumentation. Several supporting studies were conducted to define specific chamber requirements, to determine the sensitivity of the measurement techniques to be incorporated in the chamber, and to establish procedures for handling samples prior to their installation in the chamber. A bibliography and literature survey of contamination-related articles is included
    corecore