25 research outputs found

    Design of a low-current shunt-feedback transimpedance amplifier with inherent loop-stability

    Get PDF
    In this paper we propose a new architecture for enhancing the performance of a transimpedance amplifier used for low-currents, and in particular, that used in biosensing. It is usually the first block in biomedical acquisition systems for converting a current in the nanoampere and picoampere range into a proportional voltage, with an amplitude suitable for further processing. There exist two main amplifier topologies for achieving this, current-mode and shunt-feedback mode. This paper introduces a shunt-feedback amplifier that embodies current-mode operation and thereby offers the advantages of both existing schemes. A conventional shunt-feedback amplifier has a number of stages and requires compensation components to achieve stability of the feedback loop. The exemplary circuit described is inherently stable because a high gain is effectively achieved in one stage that has a dominant pole controlling the frequency response. Exhibiting complementary symmetry, the configuration has an input port that is very close to earth potential. This enables the configuration to handle bidirectional input signals such are as met with in electrochemical ampero-metric biosensors. For the 0.35 µm process adopted and ± 3.3 V rail supplies, the power dissipation is 330 µW. With a transimpedance gain of 120 dBΩ the incremental input and output resistances are less than 2 Ω and the − 3 dB bandwidth for non-optical input currents is 8.2 MHz. The input referred noise current is 3.5 pA/√Hz

    Imaging through obscurants using time-correlated single-photon counting in the short-wave infrared

    Get PDF
    Single-photon time-of-flight (ToF) light detection and ranging (LiDAR) systems have emerged in recent years as a candidate technology for high-resolution depth imaging in challenging environments, such as long-range imaging and imaging in scattering media. This Thesis investigates the potential of two ToF single-photon depth imaging systems based on the time-correlated single-photon (TCSPC) technique for imaging targets in highly scattering environments. The high sensitivity and picosecond timing resolution afforded by the TCSPC technique offers high-resolution depth profiling of remote targets while maintaining low optical power levels. Both systems comprised a pulsed picosecond laser source with an operating wavelength of 1550 nm, and employed InGaAs/InP SPAD detectors. The main benefits of operating in the shortwave infrared (SWIR) band include improved atmospheric transmission, reduced solar background, as well as increased laser eye-safety thresholds over visible band sensors. Firstly, a monostatic scanning transceiver unit was used in conjunction with a single-element Peltier-cooled InGaAs/InP SPAD detector to attain sub-centimetre resolution three-dimensional images of long-range targets obscured by camouflage netting or in high levels of scattering media. Secondly, a bistatic system, which employed a 32 × 32 pixel format InGaAs/InP SPAD array was used to obtain rapid depth profiles of targets which were flood-illuminated by a higher power pulsed laser source. The performance of this system was assessed in indoor and outdoor scenarios in the presence of obscurants and high ambient background levels. Bespoke image processing algorithms were developed to reconstruct both the depth and intensity images for data with very low signal returns and short data acquisition times, illustrating the practicality of TCSPC-based LiDAR systems for real-time image acquisition in the SWIR wavelength region - even in the photon-starved regime.The Defence Science and Technology Laboratory ( Dstl) National PhD Schem

    Advanced photon counting techniques for long-range depth imaging

    Get PDF
    The Time-Correlated Single-Photon Counting (TCSPC) technique has emerged as a candidate approach for Light Detection and Ranging (LiDAR) and active depth imaging applications. The work of this Thesis concentrates on the development and investigation of functional TCSPC-based long-range scanning time-of-flight (TOF) depth imaging systems. Although these systems have several different configurations and functions, all can facilitate depth profiling of remote targets at low light levels and with good surface-to-surface depth resolution. Firstly, a Superconducting Nanowire Single-Photon Detector (SNSPD) and an InGaAs/InP Single-Photon Avalanche Diode (SPAD) module were employed for developing kilometre-range TOF depth imaging systems at wavelengths of ~1550 nm. Secondly, a TOF depth imaging system at a wavelength of 817 nm that incorporated a Complementary Metal-Oxide-Semiconductor (CMOS) 32×32 Si-SPAD detector array was developed. This system was used with structured illumination to examine the potential for covert, eye-safe and high-speed depth imaging. In order to improve the light coupling efficiency onto the detectors, the arrayed CMOS Si-SPAD detector chips were integrated with microlens arrays using flip-chip bonding technology. This approach led to the improvement in the fill factor by up to a factor of 15. Thirdly, a multispectral TCSPC-based full-waveform LiDAR system was developed using a tunable broadband pulsed supercontinuum laser source which can provide simultaneous multispectral illumination, at wavelengths of 531, 570, 670 and ~780 nm. The investigated multispectral reflectance data on a tree was used to provide the determination of physiological parameters as a function of the tree depth profile relating to biomass and foliage photosynthetic efficiency. Fourthly, depth images were estimated using spatial correlation techniques in order to reduce the aggregate number of photon required for depth reconstruction with low error. A depth imaging system was characterised and re-configured to reduce the effects of scintillation due to atmospheric turbulence. In addition, depth images were analysed in terms of spatial and depth resolution

    Spectral LADAR: Active Range-Resolved Imaging Spectroscopy

    Get PDF
    Imaging spectroscopy using ambient or thermally generated optical sources is a well developed technique for capturing two dimensional images with high per-pixel spectral resolution. The per-pixel spectral data is often a sufficient sampling of a material's backscatter spectrum to infer chemical properties of the constituent material to aid in substance identification. Separately, conventional LADAR sensors use quasi-monochromatic laser radiation to create three dimensional images of objects at high angular resolution, compared to RADAR. Advances in dispersion engineered photonic crystal fibers in recent years have made high spectral radiance optical supercontinuum sources practical, enabling this study of Spectral LADAR, a continuous polychromatic spectrum augmentation of conventional LADAR. This imaging concept, which combines multi-spectral and 3D sensing at a physical level, is demonstrated with 25 independent and parallel LADAR channels and generates point cloud images with three spatial dimensions and one spectral dimension. The independence of spectral bands is a key characteristic of Spectral LADAR. Each spectral band maintains a separate time waveform record, from which target parameters are estimated. Accordingly, the spectrum computed for each backscatter reflection is independently and unambiguously range unmixed from multiple target reflections that may arise from transmission of a single panchromatic pulse. This dissertation presents the theoretical background of Spectral LADAR, a shortwave infrared laboratory demonstrator system constructed as a proof-of-concept prototype, and the experimental results obtained by the prototype when imaging scenes at stand off ranges of 45 meters. The resultant point cloud voxels are spectrally classified into a number of material categories which enhances object and feature recognition. Experimental results demonstrate the physical level combination of active backscatter spectroscopy and range resolved sensing to produce images with a level of complexity, detail, and accuracy that is not obtainable with data-level registration and fusion of conventional imaging spectroscopy and LADAR. The capabilities of Spectral LADAR are expected to be useful in a range of applications, such as biomedical imaging and agriculture, but particularly when applied as a sensor in unmanned ground vehicle navigation. Applications to autonomous mobile robotics are the principal motivators of this study, and are specifically addressed

    Proof-of-concept of a single-point Time-of-Flight LiDAR system and guidelines towards integrated high-accuracy timing, advanced polarization sensing and scanning with a MEMS micromirror

    Get PDF
    Dissertação de mestrado integrado em Engenharia Física (área de especialização em Dispositivos, Microssistemas e Nanotecnologias)The core focus of the work reported herein is the fulfillment of a functional Light Detection and Ranging (LiDAR) sensor to validate the direct Time-of-Flight (ToF) ranging concept and the acquisition of critical knowledge regarding pivotal aspects jeopardizing the sensor’s performance, for forthcoming improvements aiming a realistic sensor targeted towards automotive applications. Hereupon, the ToF LiDAR system is implemented through an architecture encompassing both optical and electronical functions and is subsequently characterized under a sequence of test procedures usually applied in benchmarking of LiDAR sensors. The design employs a hybrid edge-emitting laser diode (pulsed at 6kHz, 46ns temporal FWHM, 7ns rise-time; 919nm wavelength with 5nm FWHM), a PIN photodiode to detect the back-reflected radiation, a transamplification stage and two Time-to-Digital Converters (TDCs), with leading-edge discrimination electronics to mark the transit time between emission and detection events. Furthermore, a flexible modular design is adopted using two separate Printed Circuit Boards (PCBs), comprising the transmitter (TX) and the receiver (RX), i.e. detection and signal processing. The overall output beam divergence is 0.4º×1º and an optical peak power of 60W (87% overall throughput) is realized. The sensor is tested indoors from 0.56 to 4.42 meters, and the distance is directly estimated from the pulses transit time. The precision within these working distances ranges from 4cm to 7cm, reflected in a Signal-to-Noise Ratio (SNR) between 12dB and 18dB. The design requires a calibration procedure to correct systematic errors in the range measurements, induced by two sources: the timing offset due to architecture-inherent differences in the optoelectronic paths and a supplementary bias resulting from the design, which renders an intensity dependence and is denoted time-walk. The calibrated system achieves a mean accuracy of 1cm. Two distinct target materials are used for characterization and performance evaluation: a metallic automotive paint and a diffuse material. This selection is representative of two extremes of actual LiDAR applications. The optical and electronic characterization is thoroughly detailed, including the recognition of a good agreement between empirical observations and simulations in ZEMAX, for optical design, and in a SPICE software, for the electrical subsystem. The foremost meaningful limitation of the implemented design is identified as an outcome of the leading-edge discrimination. A proposal for a Constant Fraction Discriminator addressing sub-millimetric accuracy is provided to replace the previous signal processing element. This modification is mandatory to virtually eliminate the aforementioned systematic bias in range sensing due to the intensity dependency. A further crucial addition is a scanning mechanism to supply the required Field-of-View (FOV) for automotive usage. The opto-electromechanical guidelines to interface a MEMS micromirror scanner, achieving a 46º×17º FOV, with the LiDAR sensor are furnished. Ultimately, a proof-of-principle to the use of polarization in material classification for advanced processing is carried out, aiming to complement the ToF measurements. The original design is modified to include a variable wave retarder, allowing the simultaneous detection of orthogonal linear polarization states using a single detector. The material classification with polarization sensing is tested with the previously referred materials culminating in an 87% and 11% degree of linear polarization retention from the metallic paint and the diffuse material, respectively, computed by Stokes parameters calculus. The procedure was independently validated under the same conditions with a micro-polarizer camera (92% and 13% polarization retention).O intuito primordial do trabalho reportado no presente documento é o desenvolvimento de um sensor LiDAR funcional, que permita validar o conceito de medição direta do tempo de voo de pulsos óticos para a estimativa de distância, e a aquisição de conhecimento crítico respeitante a aspetos fundamentais que prejudicam a performance do sensor, ambicionando melhorias futuras para um sensor endereçado para aplicações automóveis. Destarte, o sistema LiDAR é implementado através de uma arquitetura que engloba tanto funções óticas como eletrónicas, sendo posteriormente caracterizado através de uma sequência de testes experimentais comumente aplicáveis em benchmarking de sensores LiDAR. O design tira partido de um díodo de laser híbrido (pulsado a 6kHz, largura temporal de 46ns; comprimento de onda de pico de 919nm e largura espetral de 5nm), um fotodíodo PIN para detetar a radiação refletida, um andar de transamplificação e dois conversores tempo-digital, com discriminação temporal com threshold constante para marcar o tempo de trânsito entre emissão e receção. Ademais, um design modular flexível é adotado através de duas PCBs independentes, compondo o transmissor e o recetor (deteção e processamento de sinal). A divergência global do feixe emitido para o ambiente circundante é 0.4º×1º, apresentando uma potência ótica de pico de 60W (eficiência de 87% na transmissão). O sensor é testado em ambiente fechado, entre 0.56 e 4.42 metros. A precisão dentro das distâncias de trabalho varia entre 4cm e 7cm, o que se reflete numa razão sinal-ruído entre 12dB e 18dB. O design requer calibração para corrigir erros sistemáticos nas distâncias adquiridas devido a duas fontes: o desvio no ToF devido a diferenças nos percursos optoeletrónicos, inerentes à arquitetura, e uma dependência adicional da intensidade do sinal refletido, induzida pela técnica de discriminação implementada e denotada time-walk. A exatidão do sistema pós-calibração perfaz um valor médio de 1cm. Dois alvos distintos são utilizados durante a fase de caraterização e avaliação performativa: uma tinta metálica aplicada em revestimentos de automóveis e um material difusor. Esta seleção é representativa de dois cenários extremos em aplicações reais do LiDAR. A caraterização dos subsistemas ótico e eletrónico é minuciosamente detalhada, incluindo a constatação de uma boa concordância entre observações empíricas e simulações óticas em ZEMAX e elétricas num software SPICE. O principal elemento limitante do design implementado é identificado como sendo a técnica de discriminação adotada. Por conseguinte, é proposta a substituição do anterior bloco por uma técnica de discriminação a uma fração constante do pulso de retorno, com exatidões da ordem sub-milimétrica. Esta modificação é imperativa para eliminar o offset sistemático nas medidas de distância, decorrente da dependência da intensidade do sinal. Uma outra inclusão de extrema relevância é um mecanismo de varrimento que assegura o cumprimento dos requisitos de campo de visão para aplicações automóveis. As diretrizes para a integração de um micro-espelho no sensor concebido são providenciadas, permitindo atingir um campo de visão de 46º×17º. Conclusivamente, é feita uma prova de princípio para a utilização da polarização como complemento das medições do tempo de voo, de modo a suportar a classificação de materiais em processamento avançado. A arquitetura original é modificada para incluir uma lâmina de atraso variável, permitindo a deteção de estados de polarização ortogonais com um único fotodetetor. A classificação de materiais através da aferição do estado de polarização da luz refletida é testada para os materiais supramencionados, culminando numa retenção de polarização de 87% (tinta metálica) e 11% (difusor), calculados através dos parâmetros de Stokes. O procedimento é independentemente validado com uma câmara polarimétrica nas mesmas condições (retenção de 92% e 13%)

    High Precision Hybrid Pulse and Phase-Shift Laser Ranging System

    Get PDF
    With the rapid development of military, aerospace, and precision manufacturing technology, a multitude of situations need to carry out a large-range and high-precision distance measurement. The growth of measurement applications has led to a higher requirement for the laser ranging technology which can be accomplished by using different patterns. At present, the pulse laser ranging method is widely used for medium-range and long-range measurement because of the fast measurement speed and considerable measurement range. However, the ranging precision is low. The short-distance measurement mostly adopts the phase-shift laser ranging method which has high ranging accuracy but limited measurement range. Therefore, the research on lifting the accuracy of pulse laser ranging method and extending the measurement range of the phase-shift laser ranging method will be carried out. In this thesis, combining the existing pulse laser ranging system and phase-shift laser ranging system, dual-frequency and single-frequency hybrid pulse and phase-shift laser ranging systems are proposed. The basis for solving the current problems of poor measurement precision in pulse laser ranging method and short measurement distance in phase-shift laser ranging method are provided. Also, the designed structures have a broad application prospect in the fields of industrial production, military, and aviation. At the beginning of the thesis, the principle and characteristics of the current typical laser ranging methods are introduced and analyzed. According to the Fourier Series theory, the spectrum analysis of the pulse signal and the relationship between the pulse signal and the same-frequency sinusoidal signal, the idea of phase-shift laser ranging based on pulse modulation signal is generated. Instead of a continuous sinusoidal signal, the laser is modulated with a periodic pulse signal. Distance measurement by calculating the phase difference on the sinusoidal signal extracted from the pulse signal with the same frequency at the receiving end. Based on the principle of conventional dual-frequency phase-shift laser ranging method, a dual-frequency pulse laser ranging method is proposed. The distance to be measured is obtained by transmitting two periodic pulse signals with different frequency and then combining the implementation of rough and accurate measurement outcomes. Afterward, a single-frequency pulse laser ranging method is introduced. After receiving the pulse signal, the direct counter method is used to realize rough measurement and phase-shift of the co-frequency sinusoidal signal is utilized to improve the ranging accuracy. This proposed model has the advantages of high ranging precision and long-distance measurement without any other auxiliary frequency. The accuracy of the phase difference calculation is the most critical element in both the dual-frequency and single-frequency laser ranging systems. Currently, the commonly used phase difference calculation methods operated in phase-shift laser ranging system are digital synchronous detection, fast Fourier transform method, and all phase fast Fourier transform method. Published works have discussed the performance of frequency estimation and initial phase calculation using these approaches. In this thesis, the precision of phase difference measurement based on these methods above is compared. The effects of normalized frequency deviation, white Gaussian noise, harmonics are simulated in MATLAB. Simulation results show that all phase fast Fourier transform method has a superior anti-noise ability so that exceptional accuracy of phase difference measurement can be achieved. Furthermore, as the number of sampling points increases, all phase fast Fourier transform method will obtain a more accurate calculation consequence. Finally, this thesis carries on the co-simulation test of the designed dual-frequency and single-frequency hybrid pulse and phase-shift laser ranging systems in Optisystem and MATLAB. The transmitting frequencies of pulse signals operated in the dual-frequency method are 15 MHz and 150 KHz. The pulse used in the single-frequency method is set to 15 MHz. In the simulation, the performance of proposed methods is tested by setting various measuring distance. When the number of sampling points is 1024, the standard deviation and ranging error of the dual-frequency method are 3.72 cm and 13.6 cm within 963.15 meters. For the single-frequency method, the results show a 3.78 cm standard deviation and 14.6 cm ranging error. Simulation results illustrate that the proposed ranging methods have lower ranging error compared with recently published works. It means that the combination of the pulse method and the phase-shift method can achieve high-accuracy and long-range measurement

    Air Force Institute of Technology Research Report 2011

    Get PDF
    This report summarizes the research activities of the Air Force Institute of Technology’s Graduate School of Engineering and Management. It describes research interests and faculty expertise; lists student theses/dissertations; identifies research sponsors and contributions; and outlines the procedures for contacting the school. Included in the report are: faculty publications, conference presentations, consultations, and funded research projects. Research was conducted in the areas of Aeronautical and Astronautical Engineering, Electrical Engineering and Electro-Optics, Computer Engineering and Computer Science, Systems and Engineering Management, Operational Sciences, Mathematics, Statistics and Engineering Physics

    Air Force Institute of Technology Research Report 2010

    Get PDF
    This report summarizes the research activities of the Air Force Institute of Technology’s Graduate School of Engineering and Management. It describes research interests and faculty expertise; lists student theses/dissertations; identifies research sponsors and contributions; and outlines the procedures for contacting the school. Included in the report are: faculty publications, conference presentations, consultations, and funded research projects. Research was conducted in the areas of Aeronautical and Astronautical Engineering, Electrical Engineering and Electro-Optics, Computer Engineering and Computer Science, Systems and Engineering Management, Operational Sciences, Mathematics, Statistics and Engineering Physic

    2018 Faculty Excellence Showcase, AFIT Graduate School of Engineering & Management

    Get PDF
    Excerpt: As an academic institution, we strive to meet and exceed the expectations for graduate programs and laud our values and contributions to the academic community. At the same time, we must recognize, appreciate, and promote the unique non-academic values and accomplishments that our faculty team brings to the national defense, which is a priority of the Federal Government. In this respect, through our diverse and multi-faceted contributions, our faculty, as a whole, excel, not only along the metrics of civilian academic expectations, but also along the metrics of military requirements, and national priorities

    Academic Year 2019-2020 Faculty Excellence Showcase, AFIT Graduate School of Engineering & Management

    Get PDF
    An excerpt from the Dean\u27s Message: There is no place like the Air Force Institute of Technology (AFIT). There is no academic group like AFIT’s Graduate School of Engineering and Management. Although we run an educational institution similar to many other institutions of higher learning, we are different and unique because of our defense-focused graduate-research-based academic programs. Our programs are designed to be relevant and responsive to national defense needs. Our programs are aligned with the prevailing priorities of the US Air Force and the US Department of Defense. Our faculty team has the requisite critical mass of service-tested faculty members. The unique composition of pure civilian faculty, military faculty, and service-retired civilian faculty makes AFIT truly unique, unlike any other academic institution anywhere
    corecore