287 research outputs found

    Towards Optimizing Quality Assurance Outcomes of Knowledge-Based Radiation Therapy Treatment Plans Using Machine Learning

    Get PDF
    Knowledge-based planning (KBP) techniques have been shown to provide improvements in plan quality, consistency, and efficiency for advanced radiation therapies such as volumetric modulated arc therapy (VMAT). While the potential clinical benefits of KBP methods are generally well known, comparatively less is understood regarding the impact of using these systems on resulting plan complexity and pre-treatment quality assurance (QA) measurements, especially for in-house KBP systems. Therefore, the overarching purpose of this work was to assess QA implications with using an in-house KBP system and explore data-driven methods for mitigating increased plan complexity and QA error rates without compromising dosimetric plan quality. Specifically, this study evaluated differences in dose, complexity, and QA outcomes between reference clinical plans and plans designed with a previously established in-house KBP system. Further, a machine learning model – trained and tested using a database of 500 previous VMAT treatment plans and QA measurements – was developed to predict VMAT QA measurements based on selected mechanical features of the plan. This model was deployed as a feedback mechanism within a heuristic optimization algorithm designed to modify plan parameters (identified by the machine learning model as important for accurately predicting QA outcomes) towards improving the predicted delivery accuracy of the plan. While KBP plans achieved average reductions of 6.4 Gy (p \u3c 0.001) and 8.2 Gy (p \u3c 0.001) in mean bladder and rectum dose compared to reference clinical plans across thirty-one prostate patients, significant (p \u3c 0.05) increases in both complexity and QA measurement errors were observed. A support vector machine (SVM) was developed – using a database of 500 previous VMAT plans – to predict gamma passing rates (GPRs; 3%/3mm percent dose-difference/distance-to-agreement with local normalization) based on selected complexity features. A QA-based optimization algorithm was devised by utilizing the SVM model to iteratively modify mechanical treatment features most commonly associated with suboptimal GPRs. The feasibility was evaluated on 13 prostate VMAT plans designed with an in-house KBP method. Using a maximum random leaf gap displacement setting of 3 mm, predicted GPRs increased by an average of 1.14 ± 1.25% (p = 0.006) with minimal differences in dose and radiobiological metrics

    Intensity modulated radiation therapy and arc therapy: validation and evolution as applied to tumours of the head and neck, abdominal and pelvic regions

    Get PDF
    Intensiteitsgemoduleerde radiotherapie (IMRT) laat een betere controle over de dosisdistributie (DD) toe dan meer conventionele bestralingstechnieken. Zo is het met IMRT mogelijk om concave DDs te bereiken en om de risico-organen conformeel uit te sparen. IMRT werd in het UZG klinisch toegepast voor een hele waaier van tumorlocalisaties. De toepassing van IMRT voor de bestraling van hoofd- en halstumoren (HHT) vormt het onderwerp van het eerste deel van deze thesis. De planningsstrategie voor herbestralingen en bestraling van HHT, uitgaande van de keel en de mondholte wordt beschreven, evenals de eerste klinische resultaten hiervan. IMRT voor tumoren van de neus(bij)holten leidt tot minstens even goede lokale controle (LC) en overleving als conventionele bestralingstechnieken, en dit zonder stralingsgeïnduceerde blindheid. IMRT leidt dus tot een gunstiger toxiciteitprofiel maar heeft nog geen bewijs kunnen leveren van een gunstig effect op LC of overleving. De meeste hervallen van HHT worden gezien in het gebied dat tot een hoge dosis bestraald werd, wat erop wijst dat deze “hoge dosis” niet volstaat om alle clonogene tumorcellen uit te schakelen. We startten een studie op, om de mogelijkheid van dosisescalatie op geleide van biologische beeldvorming uit te testen. Naast de toepassing en klinische validatie van IMRT bestond het werk in het kader van deze thesis ook uit de ontwikkeling en het klinisch opstarten van intensiteitgemoduleerde arc therapie (IMAT). IMAT is een rotationele vorm van IMRT (d.w.z. de gantry draait rond tijdens de bestraling), waarbij de modulatie van de intensiteit bereikt wordt door overlappende arcs. IMAT heeft enkele duidelijke voordelen ten opzichte van IMRT in bepaalde situaties. Als het doelvolume concaaf rond een risico-orgaan ligt met een grote diameter, biedt IMAT eigenlijk een oneindig aantal bundelrichtingen aan. Een planningsstrategie voor IMAT werd ontwikkeld, en type-oplossingen voor totaal abdominale bestraling en rectumbestraling werden onderzocht en klinisch toegepast

    Multi-center planning study of radiosurgery for intracranial metastases through Automation (MC-PRIMA) by crowdsourcing prior web-based plan challenge study

    Get PDF
    BACKGROUND: Planning radiosurgery to multiple intracranial metastases is complex and shows large variability in dosimetric quality among planners and treatment planning systems (TPS). This project aimed to determine whether autoplanning using the Muliple Brain Mets (AutoMBM) software can improve plan quality and reduce inter-planner variability by crowdsourcing results from prior international planning study. METHODS: Twenty-four institutions autoplanned with AutoMBM on a five metastases case from a prior international planning competition from which population statistics (means and variances) of 23 dosimetric metrics and resulting composite plan score (maximum score = 150) of other TPS (Eclipse, Monaco, RayStation, iPlan, GammaPlan, MultiPlan) were crowdsourced. Plan results of AutoMBM and each of the other TPS were compared using two sample t-tests for means and Levene's tests for variances. Plan quality of AutoMBM was correlated with the planner' experience and compared between academic and non-academic centers. RESULTS: AutoMBM produced plans with comparable composite plan score to GammaPlan, MultiPlan, Eclipse and iPlan (127.6 vs. 131.7 vs. 127.3 vs. 127.3 and 126.7; all p > 0.05) and superior to Monaco and RayStation (118.3 and 108.6; both p 0.05). CONCLUSIONS: By plan crowdsourcing prior international plan challenge, AutoMBM produces high and consistent plan quality independent of the planning experience and the institution that is crucial to addressing the technical bottleneck of SRS to intracranial metastases

    Fully automated treatment planning solutions for robotic radiotherapy

    Get PDF

    Fully automated treatment planning solutions for robotic radiotherapy

    Get PDF

    Automation of contouring and planning in Radiotherapy

    Get PDF

    Automation of contouring and planning in Radiotherapy

    Get PDF

    Per-fraction planning to enhance optimization degrees of freedom compared to the conventional single-plan approach

    Get PDF
    Objective. In conventional radiotherapy, a single treatment plan is generated pre-treatment, and delivered in daily fractions. In this study, we propose to generate different treatment plans for all fractions (‘Per-fraction’ planning) to reduce cumulative organs at risk (OAR) doses. Per-fraction planning was compared to the ‘Conventional’ single-plan approach for non-coplanar 4 × 9.5 Gy prostate stereotactic body radiation therapy (SBRT). Approach. An in-house application for fully automated, non-coplanar multi-criterial treatment planning with integrated beam angle and fluence optimization was used for plan generations. For the Conventional approach, a single 12-beam non-coplanar IMRT plan with individualized beam angles was generated for each of the 20 included patients. In Per-fraction planning, four fraction plans were generated for each patient. For each fraction, a different set of patient-specific 12-beam configurations could be automatically selected. Per-fraction plans were sequentially generated by adding dose to already generated fraction plan(s). For each fraction, the cumulative- and fraction dose were simultaneously optimized, allowing some minor constraint violations in fraction doses, but not in cumulative. Main results. In the Per-fraction approach, on average 32.9 ± 3.1 [29;39] unique beams per patient were used. PTV doses in the separate Per-fraction plans were acceptable and highly similar to those in Conventional plans, while also fulfilling all OAR hard constraints. When comparing total cumulative doses, Per-fraction planning showed improved bladder sparing for all patients with reductions in Dmean of 22.6% (p = 0.0001) and in D1cc of 2.0% (p = 0.0001), reductions in patient volumes receiving 30% and 50% of the prescribed dose of 54.7% and 6.3%, respectively, and a 3.1% lower rectum Dmean (p = 0.007). Rectum D1cc was 4.1% higher (p = 0.0001) and Urethra dose was similar. Significance. In this proof-of-concept paper, Per-fraction planning resulted in several dose improvements in healthy tissues compared to the Conventional single-plan approach, for similar PTV dose. By keeping the number of beams per fraction the same as in Conventional planning, reported dosimetric improvements could be obtained without increase in fraction durations. Further research is needed to explore the full potential of the Per-fraction planning approach.</p
    corecore